11kV 15kV 22kV 33kV Fully automated, maintenance-free 32 step voltage regulator for distribution lines

  • 11kV 15kV 22kV 33kV Fully automated, maintenance-free 32 step voltage regulator for distribution lines

Key attributes

Brand ROCKWILL
Model NO. Fully automated, maintenance-free 32 step voltage regulator for distribution lines
Rated voltage 22kV
Rated frequency 50/60Hz
Rated capacity 220kVA
Series VR

Product descriptions from the supplier

Description

Product Introduction

As a pioneer and the first source factory in China's voltage regulator industry, we have deepened our roots in the sector for decades, accumulating profound technological heritage. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have garnered widespread market trust through reliability and outstanding performance that far exceed industry standards.

The 32-Step Voltage Regulator is a fully automated, maintenance-free voltage regulator for distribution lines. This voltage regulator is designed to improve the voltage quality of the 10 kV to 35 kV distribution network, ensure that the line voltage meets the requirements, and continuously monitor the load-side voltage via a microprocessor and automatically change the voltage level to control the line voltage within the target range.

Core features

  • 32-Level Precision Regulation: Enables on-load automatic voltage adjustment with high accuracy, each step fine-tuning voltage by 0.625% for a ±10% total range.

  • Arc-Free Tap Design: Unique voltage regulating tap structure eliminates arcing during operation, extending service life to nearly 1 million cycles.

  • Fully Sealed & Maintenance-Free: IP-rated fully sealed design ensures superior weather resistance, requiring zero maintenance for reliable outdoor/indoor use.

  • Flexible Operation & Integration: Allows on/off switching of voltage regulation as needed; directly integrates with SCADA systems for seamless power distribution automation.

  • Energy-Efficient Single-Phase Design: Reduces core loss and no-load loss significantly, optimizing energy efficiency for low-carbon operations.

  • Enhanced Grid Performance: Minimizes line losses, stabilizes voltage fluctuations, and prolongs the service life of connected electrical equipment.

Specifications and Selection

We offer a wide range of voltage ratings for global applications:50Hz series: 6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV 60Hz series: 7.62kV, 13.8kV, 14.4kV, 19.92kV, 34.5kV Custom voltage ratings are also available upon request.

Rated voltage

Rated frequency

Current rating

Rated capacity

Withstand lightning impulse voltage

11kV

50Hz

50A

55kVA

95kV

11kV

50Hz

100A

110kVA

95kV

11kV

50Hz

150A

165kVA

95kV

11kV

50Hz

200A

220kVA

95kV

11kV

50Hz

300A

330kVA

95kV

11kV

50Hz

400A

440kVA

95kV

11kV

50Hz

500A

550kVA

95kV

11kV

50Hz

600A

660kVA

95kV

22kV

50Hz

50A

110kVA

150kV

22kV

50Hz

100A

220kVA

150kV

22kV

50Hz

150A

330kVA

150kV

22kV

50Hz

200A

440kVA

150kV

22kV

50Hz

300A

660kVA

150kV

22kV

50Hz

400A

880kVA

150kV

22kV

50Hz

454A

999kVA

150kV

33kV

50Hz

50A

165kVA

200kV

33kV

50Hz

100A

330kVA

200kV

33kV

50Hz

150A

495kVA

200kV

33kV

50Hz

200A

660kVA

200kV

33kV

50Hz

250A

825kVA

200kV

35kV

50Hz

50A

175kVA

200kV

35kV

50Hz

100A

350kVA

200kV

35kV

50Hz

150A

525kVA

200kV

35kV

50Hz

200A

700kVA

200kV

 

Rated Voltage (kV)

Rated Load Current (A)

Rated Capacity (kVA)

Drawing No.

A (mm)

B (mm)

C (mm)

D (mm)

E (mm)

Insulating Oil (L)

Equipment Weight (kg)

Total Weight (kg)

11.0
95kV
BIL

50

55

1

1994

1817

694

890

508

208

389

661

100

110

1

1993

1818

864

1194

559

275

432

816

150

165

1

2043

1869

1193

1161

610

370

560

1080

200

220

2

2073

1920

1003

1320

635

360

649

1211

300

330

3

2370

2208

998

1633

711

674

1007

1964

400

440

3

2624

2462

1081

1784

838

1060

1059

2545

500

550

3

2759

2608

1194

1784

972

1328

1306

3339

22.0
150kV
BIL

50

110

1

2093

1920

927

1270

635

371

455

945

100

220

2

2174

2031

1005

1405

711

550

783

1494

150

330

3

2326

2183

1075

1467

737

659

1005

1873

200

440

3

2396

2234

1036

1704

762

765

1223

2242

300

660

3

2675

2414

1330

1848

889

1213

1566

3086

33.0
200kV
BIL

50

165

3

2895

2754

799

1294

762

757

1080

1957

100

330

3

3100

2947

1003

1585

965

1480

1638

3249

150

495

3

3142

2981

1285

1839

965

1567

1765

3616

200

660

3

3264

3086

1166

1921

965

1648

1835

3915

Documentation Resource Library
Restricted
33 kV On Load Automatic Voltage Regulator Technology Specofocation
Technical Data Sheet
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.