• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Three Phase Automatic Step Voltage Regulator for Continuous / Step voltage regulation 13.8kV 14.4kV 19.92kV 34.5kV

  • Three Phase Automatic Step Voltage Regulator for Continuous / Step voltage regulation 13.8kV 14.4kV 19.92kV 34.5kV

Key attributes

Brand ROCKWILL
Model NO. Three Phase Automatic Step Voltage Regulator for Continuous / Step voltage regulation
Rated voltage 34.5kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series SVR

Product descriptions from the supplier

Description

Product Description

As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The SVR-3 is a high-performance, oil-immersed three-phase automatic voltage regulator, designed to stabilize medium-voltage distribution lines. It operates as a self-regulating autotransformer, equipped with an advanced SVR smart controller that continuously samples voltage and current signals from the grid.

By automatically adjusting output voltage through an on-load tap changer (OLTC), the SVR-3 enhances grid efficiency, ensures power quality, and accommodates varying load demands. This system integrates current transformers (CTs), voltage transformers (VTs), and limit switches to manage regulation steps precisely and reliably.

Main Features

  • Wide Regulation Range:±20% ultra-wide adjustment via 16 tap steps (2.5% per step) + self-developed high-capacity OLTC for reliable full-load switching.

  • Advanced Smart Control:Built-in SVR controller with real-time monitoring, remote configuration & communication (GPRS/GSM/Bluetooth supported).

  • Comprehensive Protection:Automatic lock-out for line faults, overload, overcurrent & undervoltage—ensuring safe, stable operation.

  • 4. Flexible Control Settings:Adjustable voltage setpoints, step limits, time delays & user-configurable system parameters.

Additional Information

  • Payment Terms: 30% T/T in advance, 70% balance against copy of B/L.

  • Packaging: Export-grade plywood cases for maximum protection during transport.

  • Core Material Options: Copper or Aluminum windings available per customer requirement. Copper offers longer lifespan and better conductivity.

  • OEM Services: Custom logo/branding available for bulk orders.

Technical Specifications

Available voltage ratings: 50Hz (6kV, 6.35kV, 11kV, 15kV, 22kV, 33kV) and 60Hz (7.62kV, 13.8kV, 14.4kV, 19.92kV, 34.5kV). Custom voltage solutions are available upon request.

Parameter

Specification

Model No.

SVR-3

Phase

Three-phase

Rated Voltage Range

2.5 kV-19.92 kV

Voltage Regulation Range

±20% (16 steps, 2.5% per step)

Rated Current

50 A-1665 A

Rated Capacity (kVA)

38.1-1000 kVA

Basic Impulse Level (BIL)

60 kV-50 kV

Frequency

50 / 60 Hz

Tap Changer Type

On-load tap changer (OLTC), motor-driven

Transformer Type

Oil-immersed autotransformer

Cooling Method

ONAN (Oil Natural Air Natural)

Our Service Commitment

  •  Responsive Pre-Sales Assistance:Swift replies to inquiries and tailored support to streamline your ordering process.

  • Transparent Production Tracking:Real-time updates at every manufacturing stage, keeping you fully informed.

  • Dependable After-Sales Service:Consistent quality support and dedicated warranty assistance post-purchase.

  • Hassle-Free Warranty Coverage:12-month quality assurance for worry-free operation and peace of mind.

Why Choose ROCKWILL

  • One-stop power equipment provider with global coverage

  • Free technical support to optimize your power solutions

  • Customized service for orders of any size

  • All products undergo strict quality inspection before delivery

  • Competitive pricing and flexible logistics from our own freight network

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.