• Disconnector Fuse Group HGLR Series, Fuse Switch Disconnector
  • Disconnector Fuse Group HGLR Series, Fuse Switch Disconnector
Disconnector Fuse Group HGLR Series, Fuse Switch Disconnector
discuss personally
Model
HGLR-630A/4P
HGLR-630A/3P
HGLR-400A/4P
HGLR-400A/3P
HGLR-250A/4P
HGLR-250A/3P
HGLR-160A/4P
HGLR-160A/3P
HGLR-63A/4P
HGLR-63A/3P
Basic info
Brand Switchgear parts
Model NO. Disconnector Fuse Group HGLR Series, Fuse Switch Disconnector
Rated normal current 250A
number of poles 4p
Series HGLR
Product Detail

Fuse Switch Disconnector Structure Characteristics

The Disconnector Fuse Group is the ideal solution for high-current connections and disconnections. Its modular design makes it easy to assemble according to your needs, while the integral structural design ensures stability. The spring energy storage mechanism allows for quick and easy connections and disconnections, even at high speeds.

  • HGLR-63~400 disconnector fuse group adopts modular design structure, which can be assembled freely according to customer requirements.
  • HGLR-630 adopts integral structural design to ensure the stability of product performance due to its high current.

The operating mechanism adopts a spring energy storage mechanism. When the product is connected and disconnected, the spring can be released instantly to realize rapid connection and disconnection (13.8 M / s), which is independent of the speed of the operating handle and greatly improves the ability to extinguish the arc.

The Disconnector Fuse Group is a safe and easy way to disconnect your electrical circuit. Made of high-quality glass fiber reinforced unsaturated polyester resin, this switch has a visual shield for easy disassembly and replacement of the fuse link. The Disconnector Fuse Group also has self-cleaning contacts for a reliable connection, and over-current and short-circuit safety protection functions.

Meet The Standard

International Standard

  • IEC60947-1 low voltage switchgear and controlgear Part 1: General
  • IEC60947-3 low voltage switchgear and control equipment, switches, isolators, disconnectors and fuse combinations

National Standard

  • GB/T 14048.1 general rules for low voltage switchgear and controlgear
  • GB/T 14048.3 low voltage switchgear and control equipment, switches, isolators, disconnectors and fuse combinations
  • GB/T 4208-1993 degrees of protection for enclosed enclosures
  • GB 13539.1 basic requirements for low voltage fuses
  • GB 13539.2 supplementary requirements for fuses used by full-time personnel of low voltage fuses

Normal Working and Installation Conditions

Operating Environment

The maximum ambient air temperature shall not exceed +40℃, with a minimum of -5℃. The average temperature inside the building should not exceed +35℃ within a 24 hour period. The installation site should not be located more than 2000m above sea level.

When the maximum temperature is above 40℃, the relative humidity of the air should not exceed 50%. However, at lower temperatures, higher relative humidity is allowed; for example, 90% at 20℃. If condensation due to temperature changes should occur, special measures should be put in place.

The pollution level of the surrounding environment is level 3.isolator switch on or off

Installation

The switch shall be installed in a place without significant shaking, shock vibration and rain and snow invasion. At the same time, the installation place shall be free of explosive dangerous medium, and the medium shall be free of gas and dust sufficient to corrode metal and damage insulation.

Isolating switch fuse group different frame fuses

Rated current of disconnector fuse group (A)

Rated current of fuse link (A)

Fuse size

63

2、4、6、10、16、20、25、32、40、50、63

00C

160

2、4、6、10、16、20、25、32、40、50、63、80、100、125、160

00

250

16、20、25、40、50、63、80、100、125、160、200、250

1

400

50、63、80、100、125、160、200、250、315、400

2

630

200、250、315、400、500、630

3

Electrical and mechanical properties of HGLR-63~630 disconnector fuse group

Electrical parameters Agreed heating current Ith (A)

63

160 250 400

630

  Fuse size

00C

00 1 2

3

  Rated insulation voltage Ui

800

800 800 800

800

  Dielectric strength (V)

2000

2000 2000 2000

2000

  Rated impulse withstand voltage Uimp kV

8

8 8 8

8

  Rated working current Ie (A)

415V

AC-23B 63 160 250 400

630

   

690V

AC-21B 40 100 200 315

400

  Limit short-circuit current(Iq)(KA)

20

20 20 20

20

Making and breaking capacity (arms) Rated making capacity

630

1600 2500 4000

6300

  Rated breaking capacity

504

1280 2000 3200

5040

Operational 

 

performance

Mechanical life

1700

1400 1400 800

800

  Electrical life

300

200 200 200

200

Weight Poles

1

1.8 3.2 4.8

16

  4 Poles

1.,3

2.3 4.5 6.1

19

Fuse Switch Disconnector Outline and Installation Dimension (mm)

Specifications

A

B C D E F G H K N

M

HGLR-63/3

134

118 31 70 118 134 102 32 97 9.5 5
HGLR-63/4

166

118 31 70 118 134 102 32 97 9.5

5

Fuse Switch Disconnector

Specifications

A

B C D E H M K N P U L

ΦX

HGLR-160/3

165

162 192 118 127 108 67 90 141 36 115 5

8.8

HGLR-160/4

200

162 192 118 127 144 67 90 141 36 115 5

8.8

HGLR-250/3

236

195 200 160 146 180 93 137 165 60 145 6

11

HGLR-250/4

296

195 200 160 146 240 93 137 165 60 145 6

11

HGLR-400/3

281

205 200 170 149 198 124 137 175 66 145 6

11

HGLR-400/4

347

205 200 170 149 264 124 137 175 66 145 6

11

Fuse Switch Disconnector

Specifications

A

B C D E H M K N P U L

ΦX

HGLR-160/3

165

162 150~300 118 127 108 67 90 141 36 126 5 8.8
HGLR-160/4

200

162 150~300 118 127 144 67 90 141 36 126 5

8.8

HGLR-250/3

236

195 150~300 160 146 180 93 137 165 60 126 6

11

HGLR-250/4

296

195 150~300 160 146 240 93 137 165 60 126 6

11

HGLR-400/3

281

205 150~300 170 149 198 124 137 175 66 126 6

11

HGLR-400/4

347

205 150~300 170 149 264 124 137 175 66 126 6

11

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!