• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Digital Timer Switch THC 20-1C Weekly Programmable

  • Digital Timer Switch THC 20-1C Weekly Programmable
  • Digital Timer Switch THC 20-1C Weekly Programmable
  • Digital Timer Switch THC 20-1C Weekly Programmable

Key attributes

Brand Switchgear parts
Model NO. Digital Timer Switch THC 20-1C Weekly Programmable
Rated voltage AC220V
Rated normal current 25A
Rated frequency 50/60Hz
Series THC-20

Product descriptions from the supplier

Description

The THC-20 series timer is an electronic digital programmable timer that replaces mechanical ones. It has a small set time of 15 minutes and is very easy to operate. At the same time, the display screen of the THC-20 programmable timer adopts LED backlight, and the built-in battery allows it to display 24 hours a day. It can be lit up when operated by the keyboard and runs normally after a power outage, making it a cost-effective digital timer.

THC-20 Programmable Timer Product Features:
1. 24-hour time controller with DIN standard size and DIN35mm standard rail installation.                                             
2. Replace mechanical methods with electronic ones.
3. 15 minutes is a small set time, and the operation is very easy.
4. 24-hour continuous display, LED backlight, illuminated during keyboard operation.
5. Equipped with a built-in battery, it will continue to operate as usual after a power outage.

Features

ItemNo

THC20-1C 16A,THC20-1C 20A, THC20-1C 25A,THC20-1A 30A

Switching frequency

≤1s/d(25℃)

Contact Capacity

THC20-1C 16A Resistive: 16A/250VAC(cosφ=1)
THC20-1C 20A Resistive: 20A/250VAC(cosφ=1)
THC20-1C 25A Resistive: 25A/250VAC(cosφ=1)
THC20-1A 30A Resistive: 30A/250VAC(cosφ=1)

Electrical life

LCD

Mounting

DIN rail mounting

Voltage range

AC 220-240V 50Hz/60Hz(Other special voltages can be customized)

Timing error

AC 180-250V

Display

4VA (max)

Power cornsumption

48ON/48OFF

MEAS

460x320x290mm

Relative humidity

35-85%RH

Contact

1NO+1NC/ 1NC

N.W

17KG

G.W

17.5KG

Control current

16A,20A,25A,30A

Min.switching time

15 min

Mechanical life

10⁵tims (Rated load)

Temperature

10~40℃

QTY

100PCS

Documentation Resource Library
Restricted
Digital Timer Switch THC 20-1C Weekly Programmable Catalogue
Catalogue
English
Consulting
Consulting
FAQ
Q: What scenarios is the THC 20-1C suitable for?
A:

Core application scenarios include:

· Commercial scenarios: Timed switching of advertising light boxes and store window lighting;

· Agricultural scenarios: Timed control of greenhouse irrigation systems and seedling fill lights;

· Industrial scenarios: Timed start and stop of small production equipment and exhaust fans;

· Civil scenarios: Timed operation of household aquariums and humidifiers.

Q: What is the THC 20-1C Weekly Programmable Timer Switch and what are its core functions?
A:

The THC 20-1C is a single-channel digital timer switch compatible with AC 220-240V/50-60Hz voltage. It supports 7-day cycle timing and can set multiple groups of on/off programs. Its core functions include power failure memory (built-in lithium battery life ≥ 3 years), 12/24-hour format switching, manual/automatic mode conversion. It adopts 35mm standard DIN rail mounting and is suitable for commercial lighting, agricultural aquaculture, and small equipment timing control scenarios.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.