Key attributes

Brand ROCKWILL
Model NO. Automatic Tap - Changing Voltage Regulator – 7.62 kV 11kV 13.8 kV 14.4 kV 19.92 kV 34.5 kV, IEEE compliant for Power Industry
Rated voltage 34.5kV
Rated frequency 50/60Hz
Rated capacity 250kVA
Series RVR

Product descriptions from the supplier

Description

Description

 As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 stands as a single-phase oil-immersed automatic voltage regulator engineered with an autotransformer configuration at its core. Outfitted with a state-of-the-art RVR control unit, it constantly captures real-time voltage and current feedback from the power distribution network. Leveraging a built-in on-load tap changer (OLTC), the regulator dynamically fine-tunes voltage output to align with fluctuating load requirements—effectively enhancing grid voltage stability while optimizing overall system operational efficiency.

This integrated solution merges three key components: a tap-adjustable transformer, a motorized switching mechanism, and an intelligent control system. Together, they deliver high-precision automatic voltage regulation with exceptional reliability, ensuring consistent performance even in dynamic power distribution scenarios.

Key Features

  • Broad Voltage Regulation Range: Offers precise voltage adjustment spanning from -10% (buck mode) to +10% (boost mode), divided into 32 fine-tuning steps with a granularity of approximately 0.625% per step. This wide range ensures flexible adaptation to diverse grid voltage fluctuations and load demands.

  • Intelligent Control System: Equipped with a proprietary RVR controller, the regulator supports GPRS/GSM and Bluetooth communication protocols. This enables seamless real-time data collection (e.g., voltage, current, operating status) and remote operation capabilities, facilitating efficient monitoring and management of the device.

  • Comprehensive Protection Mechanisms: Integrates multi-layer protection functions to safeguard the regulator and connected equipment, including lock-out protection for line faults, overload protection, overcurrent protection, and undervoltage protection. These mechanisms effectively prevent damage caused by abnormal operating conditions, enhancing system reliability.

  • Highly Customizable Parameters: Allows users to flexibly adjust key settings according to specific application requirements, such as voltage reference values, tap step limits, tap switching delay time, and other user-defined control parameters. This customization capability ensures optimal performance in various power distribution scenarios.

Technical Parameters

RegulatorContinuous / Step voltage regulation Single-phase overhead voltage regulator 7.62 kV 13.8 kV 14.4 kV 19.92 kV 34.5 kVsingle phase – IEEE C57.12 for Power Industry 

Parameter

Specification

Model No.

RVR-1

Rated Voltage

11 kV

Phase

Single-phase

Mounting Type

Pole-mounted

Voltage Regulation

±10% (Boost/Buck)

Tap Steps

32 steps

Step Size

Approx. 0.625% per step

Transformer Type

Oil-immersed auto-transformer

Core Type

Core-type, ring shape

Cooling Method

Oil-immersed

Controller

RVR Smart Controller (GPRS / GSM / Bluetooth)

Sensing Elements

Voltage and current transformers (CT & VT)

Protection Functions

Line fault, Overload, Overcurrent, Undervoltage

Frequency

50 Hz / 60 Hz

Certification

ISO9001-2000

Standards Compliance

IEC / ANSI / GB

Material

Copper winding, transformer oil

Color Options

Gray, Green, or Customized

Transport Package

Wooden Case

Trademark / Brand

Rockwill

Country of Origin

Zhejiang, China

HS Code

8504231100

50Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

6/6.35

50

30/32

75/95

28

A

100

60/64

150

90/95

200

120/127

300

180/191

400

240/254

500

300/318

600

360/381

11

50

55

100

110

150

165

200

220

300

330

400

440

500

550

600

660

15

50

75

125/150

50

100

150

150

225

200

300

300

450

400

600

500

750

22

50

110

100

220

150

330

200

440

300

660

33

50

165

170/200

70

100

330

150

495

200

660

250

825

300

990

60Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

7.62

50

38

60/75

20

A

100

76

150

114

219

167

328

250

438

333

546

416

13.8

50

69

95/125

38

100

138

150

207

200

276

300

414

400

552

14.4

50

72

100

144

200

288

300

432

400

576

19.92

50

100

170/200

70

100

200

167

333

200

400

335

667

34.5

50

165

100

330

150

495

200

660

Standard Configuration

  • Tap changer with motor drive and power supply unit

  • RVR-type intelligent control cabinet with removable front panel

  • Voltage and current sensing from CTs and VTs

  • Position indicator with ADD-AMP adjustment

  • High-creepage porcelain bushings for insulation strength

  • Oil drain valve with sampling feature

  • Pressure relief device for safety protection

  • External MOV-type surge arresters

  • Oil sight gauge for monitoring oil level

  • Durable nameplate and lifting lugs

  • Conformally coated circuit boards for enhanced durability

Application Scenarios

  • Feeder voltage regulation for rural or long-distance distribution lines

  • Industrial areas with variable load profiles

  • Distribution networks requiring automatic and precise voltage control

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: Is this automatic tap-changing voltage regulator suitable for single-phase overhead power grids?
A:

 Yes. This IEEE-compliant automatic tap-changing voltage regulator (available in 7.62kV–34.5kV) is designed to support single-phase overhead power systems, delivering reliable step voltage regulation for the power industry.

Q: Does the IEEE-compliant automatic tap-changing voltage regulator support overload protection?
A:

Yes. Equipped with built-in overload protection, this voltage regulator (available in 7.62kV–34.5kV) ensures safe operation under abnormal load conditions, fully complying with power industry safety standards and IEEE requirements.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.