Automatic Tap - Changing Voltage Regulator – 7.62 kV 11kV 13.8 kV 14.4 kV 19.92 kV 34.5 kV, IEEE compliant for Power Industry

  • Automatic Tap - Changing Voltage Regulator – 7.62 kV 11kV 13.8 kV 14.4 kV 19.92 kV 34.5 kV, IEEE compliant for Power Industry

Key attributes

Brand ROCKWILL
Model NO. Automatic Tap - Changing Voltage Regulator – 7.62 kV 11kV 13.8 kV 14.4 kV 19.92 kV 34.5 kV, IEEE compliant for Power Industry
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 250kVA
Series RVR

Product descriptions from the supplier

Description

Description

 As a pioneer and the first source factory in China's voltage regulator industry, we have been deeply rooted in the sector for decades, accumulating profound technical expertise. Leveraging top-tier R&D capabilities and a mature manufacturing system, our products have gained widespread market trust with reliability and performance that far exceed industry standards.

The RVR-1 stands as a single-phase oil-immersed automatic voltage regulator engineered with an autotransformer configuration at its core. Outfitted with a state-of-the-art RVR control unit, it constantly captures real-time voltage and current feedback from the power distribution network. Leveraging a built-in on-load tap changer (OLTC), the regulator dynamically fine-tunes voltage output to align with fluctuating load requirements—effectively enhancing grid voltage stability while optimizing overall system operational efficiency.

This integrated solution merges three key components: a tap-adjustable transformer, a motorized switching mechanism, and an intelligent control system. Together, they deliver high-precision automatic voltage regulation with exceptional reliability, ensuring consistent performance even in dynamic power distribution scenarios.

Key Features

  • Broad Voltage Regulation Range: Offers precise voltage adjustment spanning from -10% (buck mode) to +10% (boost mode), divided into 32 fine-tuning steps with a granularity of approximately 0.625% per step. This wide range ensures flexible adaptation to diverse grid voltage fluctuations and load demands.

  • Intelligent Control System: Equipped with a proprietary RVR controller, the regulator supports GPRS/GSM and Bluetooth communication protocols. This enables seamless real-time data collection (e.g., voltage, current, operating status) and remote operation capabilities, facilitating efficient monitoring and management of the device.

  • Comprehensive Protection Mechanisms: Integrates multi-layer protection functions to safeguard the regulator and connected equipment, including lock-out protection for line faults, overload protection, overcurrent protection, and undervoltage protection. These mechanisms effectively prevent damage caused by abnormal operating conditions, enhancing system reliability.

  • Highly Customizable Parameters: Allows users to flexibly adjust key settings according to specific application requirements, such as voltage reference values, tap step limits, tap switching delay time, and other user-defined control parameters. This customization capability ensures optimal performance in various power distribution scenarios.

Technical Parameters

RegulatorContinuous / Step voltage regulation Single-phase overhead voltage regulator 7.62 kV 13.8 kV 14.4 kV 19.92 kV 34.5 kVsingle phase – IEEE C57.12 for Power Industry 

Parameter

Specification

Model No.

RVR-1

Rated Voltage

11 kV

Phase

Single-phase

Mounting Type

Pole-mounted

Voltage Regulation

±10% (Boost/Buck)

Tap Steps

32 steps

Step Size

Approx. 0.625% per step

Transformer Type

Oil-immersed auto-transformer

Core Type

Core-type, ring shape

Cooling Method

Oil-immersed

Controller

RVR Smart Controller (GPRS / GSM / Bluetooth)

Sensing Elements

Voltage and current transformers (CT & VT)

Protection Functions

Line fault, Overload, Overcurrent, Undervoltage

Frequency

50 Hz / 60 Hz

Certification

ISO9001-2000

Standards Compliance

IEC / ANSI / GB

Material

Copper winding, transformer oil

Color Options

Gray, Green, or Customized

Transport Package

Wooden Case

Trademark / Brand

Rockwill

Country of Origin

Zhejiang, China

HS Code

8504231100

50Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

6/6.35

50

30/32

75/95

28

A

100

60/64

150

90/95

200

120/127

300

180/191

400

240/254

500

300/318

600

360/381

11

50

55

100

110

150

165

200

220

300

330

400

440

500

550

600

660

15

50

75

125/150

50

100

150

150

225

200

300

300

450

400

600

500

750

22

50

110

100

220

150

330

200

440

300

660

33

50

165

170/200

70

100

330

150

495

200

660

250

825

300

990

60Hz

Voltage

(kV)

Current

(A)

Capacity

(kVA)

BIL (kV)

Power Frequency Withstand Voltage (kV)

Insulation Class

7.62

50

38

60/75

20

A

100

76

150

114

219

167

328

250

438

333

546

416

13.8

50

69

95/125

38

100

138

150

207

200

276

300

414

400

552

14.4

50

72

100

144

200

288

300

432

400

576

19.92

50

100

170/200

70

100

200

167

333

200

400

335

667

34.5

50

165

100

330

150

495

200

660

Standard Configuration

  • Tap changer with motor drive and power supply unit

  • RVR-type intelligent control cabinet with removable front panel

  • Voltage and current sensing from CTs and VTs

  • Position indicator with ADD-AMP adjustment

  • High-creepage porcelain bushings for insulation strength

  • Oil drain valve with sampling feature

  • Pressure relief device for safety protection

  • External MOV-type surge arresters

  • Oil sight gauge for monitoring oil level

  • Durable nameplate and lifting lugs

  • Conformally coated circuit boards for enhanced durability

Application Scenarios

  • Feeder voltage regulation for rural or long-distance distribution lines

  • Industrial areas with variable load profiles

  • Distribution networks requiring automatic and precise voltage control

Documentation Resource Library
Restricted
6kV to 34.5kV Single Phase Automatic Voltage Regulator Brochure
Catalogue
English
Consulting
Consulting
FAQ
Q: Is this automatic tap-changing voltage regulator suitable for single-phase overhead power grids?
A:

 Yes. This IEEE-compliant automatic tap-changing voltage regulator (available in 7.62kV–34.5kV) is designed to support single-phase overhead power systems, delivering reliable step voltage regulation for the power industry.

Q: Does the IEEE-compliant automatic tap-changing voltage regulator support overload protection?
A:

Yes. Equipped with built-in overload protection, this voltage regulator (available in 7.62kV–34.5kV) ensures safe operation under abnormal load conditions, fully complying with power industry safety standards and IEEE requirements.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.