• 6kV~10kV Customized High Voltage Shunt Capacitor Bank
6kV~10kV Customized High Voltage Shunt Capacitor Bank
discuss personally
Model
BAMH6-5000
Basic info
Brand ROCKWILL
Model NO. 6kV~10kV Customized High Voltage Shunt Capacitor Bank
Rated voltage 6kV
Rated frequency 50/60Hz
Series BAMH
Product Detail

Overview

The 10kV assembled shunt capacitor device is used in the AC power system of 10kV and below, in areas with limited floor space or high seismic requirements, reactive power compensation for industrial frequency power systems.

Main features

  • The use of a new type of integrated capacitor internal unit, the quality is safe and reliable.

  •  The small unit has an internal fuse to improve the safety and reliability of the operation of the collective capacitor.

  •  The product has a compact structure and a small footprint.

  • The infrastructure is simple and the amount of on-site installation is small.

  • There are few exposed conductors, and the amount of maintenance is small.

Technical data

  • Rated frequency: 50Hz

  • Rated voltage: 6kV, 10kV

  • Rated capacity: 800~10000kvar

  • Number of phases: three-phase or single-phase

  • Loss tangent value: tanδ is not more than 0.0005

  • Capacitance deviation: The deviation between the measured capacitance and its rated value shall not exceed 0~+5%, and the ratio of the maximum value to the minimum value between any two line terminals of the three-phase capacitor shall not exceed 1.02.

  • The capacitor can operate continuously at 1.1 times the rated voltage.

  • The capacitor can operate continuously when the overcurrent does not exceed 1.3 times of its rated current.

  • Climbing distance of outlet casing: ≥35mm/kV

  • Contamination level of casing: level d

Rated Frequency:

50Hz

Rated Voltage:

6kV、10kV

Rated Capacity:

800~10000kvar

Number Of Phases:

Three-phase Or Single-phase

Loss Tangent Value (tanδ):

≤0.0005

Climbing Distance Of Outlet Casing:

≥35mm/kV

Contamination Level Of Casing:

D

Color:

Customized

Package:

Export Wooden Packing



 

Rated frequency

50/60Hz

Rated voltage

6kV,10kV

Rated Capacity

800~10000kvar

Number of phases

Three-phase or single-phase

Loss tangent value (tanδ)

≤0.0005

Capacitance deviation

The deviation between the measured capacitance and its rated value shall not exceed 0~+5%, and the ratio of the maximum value to the minimum value between any two line terminals of the three-phase capacitor shall not exceed 1.02.

Climbing distance of outlet casing

≥35mm/kV

Contamination level of casing

D

Color

Customized

Package

Export wooden packing

Altitude

≤1000m

Environmental temperature category

-40/B

Surrounding environment

No severely corrosive gas and steam to metal, no conductive or explosive dust, no severe mechanical vibration.

Working Conditions

  • Altitude: ≤1000m. In plateau areas over 1000m, the prototype integrated shunt capacitors provided by our company can be used.

  • Ambient temperature category: -40/B.

  • Pollution level: Level IV.

  • Installation location: outdoor. It can also be used indoors or in areas that require a small area

  • Ambient environment: no severely corrosive gases and vapors to metals, no conductive or explosive dust, and no severe mechanical vibration.

  • When the capacitor is put into operation, the residual voltage on its terminals should not exceed 10% of the rated voltage.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!