• 35kV-110kV High Voltage Shunt Capacitor Bank With Large Capacity
35kV-110kV High Voltage Shunt Capacitor Bank With Large Capacity
discuss personally
Model
BAMH35-10000
Basic info
Brand ROCKWILL
Model NO. 35kV-110kV High Voltage Shunt Capacitor Bank With Large Capacity
Rated voltage 35kV
Rated frequency 50/60Hz
Series BAMH
Product Detail

Overview

The high-voltage and large-capacity assembled shunt capacitor device is used in AC power systems of 1000kV and belo in areas with limited floor space or high seismic requirements, providing reactive power compensation for industrial frequency power systems. 

 Main features

  • Adopting new type of integrated internal capacitor  unit, the quality is safe and reliable.

  • The product has compact structure, large capacity and small footprint.

  • The hierarchical design of multiple insulation platforms greatly improves the explosion resistance level of the product.

  • The capacitor body is designed with a terminal box with a signal collector, which is used to collect the voltage, current, temperature, pressure, gas and other signals during the operation of the capacitor, which is convenient for monitoring the operation status of the capacitor.

  • The core adopts high-quality new insulating materials and point-shaped insulation structure, which can not only ensure good internal insulation performance, but also ensure smooth heat dissipation of the core, making it safer and more reliable to operate.

  • The main components adopt bolt type and detachable structure, which is convenient for installation and transportation, as well as for on-site maintenance.

Parameters

Rated frequency

50/60Hz

Rated voltage

20kV,35kV,66kV,110kV

Rated capacity

35kV voltage level: three-phase integrated 10000kvar, single-phase 3334, 6667, 10000, 20000kvar.

66kV voltage level: single-phase 20000kvar

110kV voltage level: single-phase 80,000kvar

Number of phases

Three-phase or single-phase

Loss tangent

tanδ≤0.0005

Climbing distance of outlet casing

≥35mm/kV

Contamination level of casing

D

Capacitance deviation

The deviation between the measured capacitance and its rated value shall not exceed 0~+5%, and the ratio of the maximum value to the minimum value between any two line terminals of the three-phase capacitor shall not exceed 1.02

Altitude

≤1000m

Environmental temperature category

-40/B

Installation location

Outdoor, It can also be used indoors or in areas that require a small area

Surrounding environment

No severely corrosive gas and steam to metal, no conductive or explosive dust, no severe mechanical vibration.

Function

The high-voltage large-capacity tank type shunt capacitor mainly used for the 110kV, 66kV and 35kV side of main transformers in areas with limited area or high seismic requirements, to improve the power factor of the grid, reduce line losses, compensate to the efficiency of power supply and distribution, and improve the quality of the power supply voltage. It has the advantages of good seismic performance, small footprint, and easy installation and maintenance.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!