• 35 - 220kV Suspended Composite - Housed Metal Oxide Surge Arresters
35 - 220kV Suspended Composite - Housed Metal Oxide Surge Arresters
discuss personally
Model
YH10WX-200/520
Basic info
Brand ROCKWILL
Model NO. 35 - 220kV Suspended Composite - Housed Metal Oxide Surge Arresters
Rated voltage 200kV
Rated frequency 50/60Hz
Series YH5WX
Product Detail

Description:

35 - 220kV Suspended Composite - Housed Metal Oxide Surge Arresters are vital protective devices designed for medium to high voltage power systems ranging from 35kV to 220kV. They are suspended and installed in places such as transmission lines, substations, and near key power equipment like transformers and circuit breakers. With composite housings (usually made of silicone rubber) and advanced metal oxide varistor (MOV) technology, these arresters can effectively suppress overvoltages caused by lightning strikes, switching operations, and system faults. By diverting surge currents to the ground and clamping the voltage to a safe level, they protect the power system equipment from damage, ensuring the stable and reliable operation of the 35 - 220kV power grid.

Features:

  • Wide Voltage AdaptabilityIt is specifically designed for 35kV to 220kV medium and high voltage power systems, with rated voltages that precisely match the requirements of different voltage levels in the grid. This allows it to provide effective overvoltage protection for various parts of the power system within this voltage range.

  • Suspended Installation DesignThe suspended installation method saves space and is suitable for occasions where vertical installation space is limited, such as on transmission line towers. It can be easily integrated into the existing power system structure without occupying too much ground or equipment space, facilitating installation and maintenance.

  • Excellent Composite HousingThe composite housing made of silicone rubber has outstanding performance. It has good hydrophobicity, which can prevent moisture and pollution accumulation, reducing the risk of flashover. It also has strong resistance to aging, ultraviolet radiation, and extreme temperature changes, ensuring stable operation in harsh environmental conditions.

  • Strong Surge Withstand CapacityIt can withstand large surge currents caused by lightning and switching operations, effectively protecting the connected power equipment from the impact of overvoltages. This strong surge withstand capacity ensures the reliability of the power system even in severe weather or frequent switching operations.

  • Low Maintenance RequirementsThe composite housing is not easy to be damaged and has a long service life. It does not require frequent maintenance and overhaul, reducing the operation and maintenance costs of the power system. At the same time, the stable performance of the MOVs ensures that the arrester can work reliably for a long time.

  • Compliance with Industry StandardsIt meets relevant international and industry standards, such as IEC 60099 - 4 and ANSI/IEEE C62.11. This ensures that the arrester has good compatibility and interchangeability, and can be used in conjunction with other power equipment in the power system to ensure the safety and stability of the entire system.

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


YH5WX-51/134

51

35

40.8

73

114

134

154

400

1350

YH5WX-84/221

84

66

67.2

121

188

221

254

600

3150

YH5WX-90/235

90

66

72.5

130

201

235

270

600

3150

YH5WX-96/250

96

110

75

140

213

250

288

600

3150

YH5WX-100/260

100

110

78

145

221

260

299

600

3150

YH10WX-90/235

90

66

72.5

130

201

235

264

800

3150

YH10WX-96/250

96

110

75

140

213

250

280

800

3150

YH10WX-100/260

100

110

78

145

221

260

299

800

3150

YH10WX-102/266

102

110

79.6

148

226

266

297

800

3150

YH10WX-108/281

108

110

84

157

239

281

315

800

3150

YH10WX-192/500

192

220

150

280

426

500

560

800

6300

YH10WX-200/520

200

220

156

290

442

520

582

800

6300

YH10WX-204/532

204

220

159

296

452

532

594

800

6300

YH10WX-216/562

216

220

168.5

314

478

562

630

800

6300

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!