3.6kV-24kVThe Indoor metal-clad withdrawable switchgear

  • 3.6kV-24kVThe Indoor metal-clad withdrawable switchgear

Key attributes

Brand ROCKWILL
Model NO. 3.6kV-24kVThe Indoor metal-clad withdrawable switchgear
Rated voltage 7.2kV
Series KYN

Product descriptions from the supplier

Description

Description:

The Indoor metal-clad withdrawable switchgear(hereinafter short as switchgear) is a complete power distribution device for 3.6~40.5kV, 3-phase AC 50/60Hz,single-bus and single-bus sectionalized system.

It is mainly used for power transmission of middle/small generators in power plants; power receiving, transmission for substations in power distribution and power system of factories, mines and enterprises, and starting of large high-voltage motor, etc. so as to control, protect and monitor the system. The medium voltage switchgear meets IEC298,GB3906-91. In addition to be used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB, 3AH5 from Siemens domestic ZN65A, and VB2 from GE, etc. It is truly a power distribution device with good performance.

In order to meet the requirements for wall mounting and front-end maintenance, the medium voltage switchgear is equipped with a special current transformer, so that the operator can maintain and inspect it in front of the cubicle.

  • Enclosures able to withstand internal arcing.

  • 3 or 4 sides internal arc protection IAC: A-FL and A-FLR. Internal arc withstand: 12.5 kA 1s, 16 kA 1s and 20 kA 1s.

  • Mechanical and electrical interlocks, to prevent incorrect operations.

  • 100% factory-tested without the need for further tests on site.

  • Easy upgraded to meet your need and adapted to the extension of your installations.

  • Integration in factory-built outdoor substations for which the SM6 is particularly well designed.

  • Intelligent, connectable components like SC110 and TH110 provide continuous information about the health of your electrical installations, enabling asset management optimization through preventive maintenance.

Technical parameters:

image.png

Product detail:


企业微信截图_17211091605892.png

企业微信截图_17211092656460.png

企业微信截图_17211092834133.png

What is the working principle of the indoor metal armored pull-out  switchgear?

Circuit Control and Protection:

  • Circuit Control:

  • Circuit breakers control the opening and closing of circuits. The working principle of circuit breakers is based on electromagnetic induction and thermal effects. During normal operation, current flows through the contacts of the circuit breaker, which remain closed. When an overload condition occurs, and the current exceeds the rated current of the circuit breaker, the internal thermal trip mechanism will open the contacts due to the heat generated by the current, thereby interrupting the circuit.

  • In the event of a short circuit, the high short-circuit current will cause the internal electromagnetic trip mechanism to act instantly, quickly opening the contacts and protecting electrical equipment and lines from damage caused by excessive current.

Protection Devices:

  • Other protective devices, such as overcurrent relays and ground fault protection relays, are also equipped. These protection devices continuously monitor parameters such as current and voltage in the circuit. If any abnormality is detected, they send a trip signal to the circuit breaker, ensuring the safety of the circuit.

Power Distribution:

  • Power is introduced into the switchgear's busbar compartment via busbars. The busbars distribute the power to the circuit breakers in each branch. The circuit breakers then transmit the power to different load circuits, enabling the control of power supply to multiple loads. For example, in a building's power distribution system, medium-voltage power from a substation first enters the busbar of the switchgear and is then distributed to the distribution panels on each floor through circuit breakers, providing power to lighting, outlets, and other equipment on those floors.

Interlocking Functions:

  • To ensure operational safety, the switchgear is equipped with various interlocking mechanisms. For example:

  • The trolley can only be moved from the service position to the test or maintenance position when the circuit breaker is in the open (off) state.

  • There is an interlock between the grounding switch and the circuit breaker. When the grounding switch is in the closed (on) position, the circuit breaker cannot be closed, and vice versa.

  • These interlocking devices effectively prevent operator errors and avoid dangerous operations such as switching under load or closing the grounding switch while the circuit is energized.



Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
  • Application of Intelligent Solid Insulated Ring Main Units (SIRMUs) in the Qinzhou Distribution Network
    1 IntroductionCoastal regions face environmental challenges including heavy rainfall, lightning, high temperatures, high humidity, and high salt spray corrosion. To ensure the safety of urban distribution grids in such environments, minimize power outages caused by equipment maintenance, and prevent accidents due to equipment end-of-life and other factors affecting grid security, we have researched the use of a new type of Solid Insulated Ring Main Unit (SIRMU). This SIRMU offers long lifespan,
    08/15/2025
  • SF₆ Ring Main Units (RMUs) and Urban Grid Renovation
    Overview​Older distribution networks are primarily radial in structure, with most incoming and outgoing lines being overhead lines. The switching equipment typically consists of air-insulated vacuum circuit breakers or minimal-oil circuit breakers. These networks suffer from frequent faults, high operating costs, and prolonged, widespread power outages in the event of a failure, significantly hindering economic development.With rapid economic growth and the implementation of urban grid renovatio
    08/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.