12kV Fast Current Limiter

  • 12kV Fast Current Limiter

Key attributes

Brand RW Energy
Model NO. 12kV Fast Current Limiter
Rated voltage 12kV
Rated normal current 1250A
Series FCL

Product descriptions from the supplier

Description

Product Introduction

A switching device with extremely fast breaking speed

Reduce the investment in substations

  • Solve the short-circuit current problems encountered during the construction of new substations and the expansion of existing substations.

  • When paralleled with reactors, it is the most economical and effective way to limit short-circuit currents.

  • An ideal method for interconnecting switch cabinets and substations.

  • The only technical solution in most cases.

  • Reliability has been verified in the operation of thousands of engineering projects.

  • Has been put into use worldwide.

  • The short-circuit current will never reach the maximum expected peak value.

  • The short-circuit current is restricted during the initial rising stage.

Functions

With the growth in global energy demand, there is a need for higher-power power supplies,additional transformers and generators, and increased interconnection between independent power grids. This often leads to short-circuit currents exceeding the allowable values of equipment, resulting in dynamic and thermal damage to the equipment.Replacing existing switchgear and cable connections with new equipment that has a higher short-circuit current withstand capacity is usually technically infeasible or uneconomical for users. However, using fast current limiters to reduce short-circuit currents in new or existing systems not only solves the short-circuit capacity problem but also saves investment.Due to their slow operation, circuit breakers cannot provide protection against the excessive peak value of the first half-cycle of short-circuit currents in the system. Only fast current limiters can detect and limit the short-circuit current at the initial stage of its rise (within 1ms), so that the maximum instantaneous value of the actual short-circuit current flowing through is much lower than the expected peak value.Compared with complex conventional solutions, fast current limiters applied in transformer or generator feeder circuits, whether as bus connections or bypass current-limiting reactors,have technical advantages and economic benefits.In power plants, large industrial facilities, and grid substations, fast current limiters are ideal switchgear in all aspects for solving short-circuit current problems.

Main Parameters

Technical Parameters

Unit

1

2

3

4

5

6

7

Rated Voltage

V

750

12000

12000

17500

17500

24000

36000/40500

Rated Current

A

1250
2000
3000
4500¹)
5000¹)

1250
2000

2500
3000
4000¹)

1250
2000

2500
3000
4000¹)

1250
1600
2000
3000¹)

1250
2000
2500¹)

Rated Power Frequency Withstand Voltage

kV

3

28

28

38

38

50

75

Rated Lightning Impulse Withstand Voltage

kV

-

75

75

95

95

125

200

Rated Short - Circuit Breaking Current

kA RMS

Up to 140

Up to 210

Up to 210

Up to 210

Up to 210

Up to 140

Up to 140

Conductive Bridge Base

kg

10.5

27.5

65

27.5

65

27/31.5/33

60

Conductive Bridge

kg

17.0

12.5

15.5

14.5

17.5

19/19.5/24

42

Conductive Bridge Base and Conductive Bridge

Width mm

148

180

180

180

180

180

240

Height mm

554

651

951

651

951

740/754/837

1016

Depth mm

384

510

509

510

509

553/560/560

695

Typical Dimensions of Truck-Type Fast Current Limiter Cabinet

RatedVoltage

(kV)

RatedCurrent

(A)

RatedPowerFrequencyWithstandVoltage(kV)

RatedLightningImpulseWithstandVoltage(kV)

Height

(mm)

Width

(mm)

Depth

(mm)

Weight

(IncludingFastCurrentLimiterTruck)(kg)

12

1250

28

75

2200

1000 ²)

1634

1200

2000

2500

3000

4000 ¹)

17.5

1250

38

95

2200

1000 ²)

1634

1200

2000

3000

4000 ¹)

24

1250

50

125

2325

1000

1560

1300

1600

2000

2500 ¹)

Schematic Diagram of the Measurement and Control Device

T1 Current Transformer Matching the Fast Current Limiter

T2 Internal Intermediate Transformer of the Device

T3 Pulse Transformer

L1 Measuring Inductor

R1...R6 Adjustable Resistors

C1 Tripping Trigger Capacitor

FAQ
Q: What is the typical cabinet size?
A:

Taking 12kV/1250A as an example, the standard size of the handcart cabinet is 2200mm high, 1000mm wide, and 1634mm deep, with a weight of approximately 1200kg.

Q: Has there been a significant amount of engineering validation?
A:

Yes, the product has been put into operation in thousands of engineering projects worldwide, including power plants, industrial users, and power grid substations, and its reliability has been verified for a long time.

Q: What is the fastest action time for FCL?
A:

It can detect and start current limiting within<1ms, with a total breaking time of<10ms, much faster than conventional circuit breakers (usually>50ms).

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.