10KW ON/OFF Grid Wind Power controller

  • 10KW ON/OFF Grid Wind Power controller

Key attributes

Brand Wone Store
Model NO. 10KW ON/OFF Grid Wind Power controller
Input Voltage 380V
Power 10KW
Series WWGI

Product descriptions from the supplier

Description

Features

▪ Wind Controller &Inverter integrated machine.

▪ MPPT included, and 30-point power curve can be settable.

▪ Complete protection functions.

▪ RS485 monitoring mode optional.

Applications

▪ Distributed wind power grid-tied system.

▪ Solar &wind hybrid power grid-tied system.

▪ Wind power grid-tied system.

 

Technical Parameters                                                                                                                                                                                                  

Model

WWGI100

Wind Turbine Input

Rated input power

10kW

Max. input power

15kW

Rated input voltage

380VDC

Rated input current

15.2A

Max input current

22.8A

Cutting speed

60RPM(factory default)

Power tracking

30 points set power curve

Speed limit control

Electromagnetic speed limit

Manual brake

YES

Brake by overcurrent

YES

Brake by over rotational Speed

YES

Brake by over wind speed

optional

AC Output

Grid Type

Three-phase

Rated output power

10kW

Max output power

11kW

Rated Grid voltage

380VAC

Grid voltage range

85%~110% of rated grid voltage

Rated Grid frequency

50Hz/60Hz

Work frequency range

49Hz~51Hz/59Hz~61Hz

Rated output current

4.6A

Rated power factor

>0.98

Thdi

<5% (at rated power)

DC component

<0.5%

soft start

Yes

Restoring grid-connected functionality

Yes

Auto on/off

Yes

Protection Functions

Grid overvoltage/undervoltage protection

Yes

Grid over frequency/under frequency protection

Yes

output short circuit protection

Yes

Grid power failure protection

Yes

Anti-islanding protection

Yes

Over-temperature protection

Yes

Lightning protection

Yes

Residual current protection

Yes

General Parameters

Display mode

LED+LCD

Display information

Display: wind Voltage, Wind current,Wind power, Wind Speed, Pole Paris; Inverter voltage, Inverter current, Inverter Power, Inverter Frequency, Relay Time, power generation; BUS Voltage, Air speed, Temperature, Time, Language, ID, etc.

Status: Manual brake, automatic brake, fault indication, grid-connected state, relay state, Wind cut-in, etc.

Monitoring mode(optional)

RS485/WIFI

Monitoring contents

Telemetry: wind turbine speed, Inverter voltage, Inverter current, Inverter power, power generation,Air speed;

Remote signal: wind turbine status, wind power grid-connected inverter over-current alarm, over-voltage alarm, over-temperature alarm, fault alarm, etc.;

Remote control: modify the parameters of the wind power

Efficiency

>95%

Ambient temperature

-20℃~+40℃

Humidity

0%~90%, no condensing

Vibration resistance

Can withstand sine wave vibration with a frequency of 10Hz~50Hz and an amplitude of 0.35mm

Noise

≤65dB

Cooling mode

Air-cooled

Note: Part of parameters can be adjusted according to customer's specific demand.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
  • Risk Identification and Control Measures for Distribution Transformer Replacement Work
    1.Electric Shock Risk Prevention and ControlAccording to typical design standards for distribution network upgrades, the distance between the transformer’s drop-out fuse and the high-voltage terminal is 1.5 meters. If a crane is used for replacement, it is often impossible to maintain the required minimum safety clearance of 2 meters between the crane boom, lifting gear, slings, wire ropes, and the 10 kV live parts, posing a severe risk of electric shock.Control Measures:Measure 1:De-energize th
    12/25/2025

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.