10kV (Dual Circuit) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit

  • 10kV (Dual Circuit) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit

Key attributes

Brand ROCKWILL
Model NO. 10kV (Dual Circuit) Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit
Rated voltage 12kV
Rated frequency 50/60Hz
Series XGN

Product descriptions from the supplier

Description

Description

The 10kV Normal Pressure Sealed Air-Insulated Switchgear / Ring Main Unit (Dual Circuit) is an advanced medium-voltage power distribution device designed for dual-loop power supply systems. Operating at a rated voltage of 10kV, it adopts a normal-pressure sealed structure with air as the insulating medium, eliminating the need for SF₆ gas or other pressurized insulating materials. This switchgear integrates the functions of power distribution, protection, and control, making it suitable for scenarios requiring reliable dual-circuit power supply, such as industrial parks, urban distribution networks, high-rise buildings, and key infrastructure.

Key Features

  • Normal Pressure Sealed Design: Operates at atmospheric pressure with a hermetically sealed enclosure, preventing leakage risks associated with pressurized systems and ensuring stable insulation performance over long-term use.

  • Air Insulation: Utilizes air as the insulating medium (no need for gas treatment or refilling), reducing environmental impact and maintenance costs while meeting eco-friendly standards.

  • Dual Circuit Capability: Supports two independent power supply loops, enabling seamless switching between circuits to enhance power supply reliability and minimize downtime in case of single-loop faults.

  • Compact and Space-Saving: Optimized structure with a smaller footprint compared to traditional switchgears (similar in size to conventional pressurized models), ideal for installations with limited space.

  • High Safety and Reliability: Equipped with reliable mechanical interlocks and anti-misoperation mechanisms; all live components are enclosed to protect against moisture, dust, and corrosion, ensuring stable operation in harsh environments.

  • Low Maintenance: Simplified operating mechanism with a long mechanical life (up to 10,000 operations), reducing the need for frequent inspections and on-site maintenance, thus lowering operational costs.

  • Standardized Expansion: Designed for easy on-site installation and modular expansion, allowing quick integration into existing power grids and minimizing power outage time during upgrades.

Name

Unit

Parameter Value

Rated Voltage (Ur)

kV

12

Rated Frequency (fr)

Hz

50/60

Rated Current (Ir)

A

630

Short - time Power Frequency Withstand Voltage (Ud)

Between Fractures

kV

48

Between Phases

kV

42

Phase to Ground

kV

42

Lightning Impulse Withstand Voltage (Up)

Between Fractures

kV

95

Between Phases

kV

75

Phase to Ground

kV

75

Rated Short - time Withstand Current (Ik)

kA

20/25

Rated Short - circuit Duration (tk)

s

4

Rated Peak Withstand Current (Ip)

kA

50/63

Rated Short - circuit Breaking Current (Isc)

kA

20/25

Rated Short - circuit Making Current (Ima)

 

Vacuum Interrupter

kA

50/63

Earthing Switch



Auxiliary Circuit and Control Circuit

Rated Voltage (Ua) DC/AC

V

≤400

Power Frequency Withstand Voltage (1min)

V

2000

Mechanical Life

 

Circuit Breaker

Times

10000

Disconnecting Switch

Times

3000

Earthing Switch

Times

3000

Electrical Life  

Circuit Breaker

Class

E2

Earthing Switch

Class

E2

Protection Grade of Cabinet Enclosure


IP4X

Protection Grade of Sealed Box


IP65

FAQ
Q: Do environmentally friendly cabinets have self-healing ability after insulation breakdown?
A:
Gas-insulated environmentally friendly cabinets have certain self-healing ability. When insulation breakdown occurs due to transient overvoltage, the insulating gas (dry air, N2) molecules can recombine to restore insulation performance after the fault is removed, without permanent damage. However, solid-insulated eco-friendly cabinets do not have self-healing ability; insulation breakdown will cause permanent damage and require component replacement.
Q: In which scenarios are environmentally friendly cabinets commonly used? (e.g., urban distribution network, industrial park)
A:
They are widely used in urban distribution networks, new residential communities, industrial parks, data centers, airports, railways, and alpine/humid coastal areas. They are especially suitable for environmentally sensitive areas (e.g., scenic spots, ecological reserves) and projects with strict environmental protection requirements (e.g., green buildings, low-carbon industrial parks) due to their eco-friendly characteristics.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.