Synchronous Condenser

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is Synchronous Condenser

Like capacitor bank, we can use an overexcited synchronous motor to improve the poor power factor of a power system. The main advantage of using synchronous motor is that the improvement of power factor is smooth.
When a synchronous motor runs with over-excitation, it draws leading
current from the source. We use this property of a synchronous motor for the purpose.

Here, in a three-phase system, we connect one three-phase synchronous motor and run it at no load.
three phase synchronous motorSuppose due to a reactive load of the power system the system draws a current IL from the source at a lagging angle θL in respect of voltage. Now the motor draws a IM from the same source at a leading angle θM. Now the total current drawn from the source is the vector sum of the load current IL and motor current IM. The resultant current I drawn from the source has an angle θ in respect of voltage. The angle θ is less than angle θL. Hence power factor of the system cosθ is now more than the power factor cosθL of the system before we connect the synchronous condenser to the system.

The synchronous condenser is the more advanced technique of improving power factor than a static capacitor bank, but power factor improvement by synchronous condenser below 500 kVAR is not economical than that by a static capacitor bank. For major power network we use synchronous condensers for the purpose, but for comparatively lower rated systems we usually employ capacitor bank.

The advantages of a synchronous condenser are that we can control the power factor of system smoothly without stepping as per requirement. In case of a static capacitor bank, this fine adjustments of power factor cannot be possible rather a capacitor bank improves the power factor stepwise.
The short circuit withstand-limit of the
armature winding of a synchronous motor is high.

Although, synchronous condenser system has some disadvantages. The system is not silent since the synchronous motor has to rotate continuously.
An ideal load less synchronous motor draws leading
current at 90o(electrical).

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.