Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1

Edwiin
Field: Power switch
China

Expected service life of 30–40 years, front access, compact design equivalent to SF6-GIS, no SF6 gas handling – climate-friendly, 100% dry air insulation. The Nu1 switchgear is metal-enclosed, gas-insulated, featuring a withdrawable circuit breaker design, and has been type-tested according to relevant standards, approved by the internationally recognized STL laboratory.

Compliance Standards

  • Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for alternating current switchgear and controlgear

  • IEC 62271-200 High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

  • Circuit Breaker: IEC 62271-100 High-voltage switchgear and controlgear – Part 100: Alternating current circuit breakers

  • Disconnector / Earthing Switch: IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches

  • Current Transformer (CT): IEC 61869-2 Instrument transformers – Part 2: Current transformers

  • Voltage Transformer (VT): IEC 61869-3 Instrument transformers – Part 3: Voltage transformers

  • Insulation: IEC 60071 Insulation coordination

  • IP Code: IEC 60529 Degrees of protection provided by enclosures (IP code)

  • IK Code: IEC 62262 Degrees of protection provided by enclosures against external mechanical impacts (IK code)

  • Voltage Detection System (VDS): IEC 62271-213 Voltage detecting systems for high-voltage switchgear and controlgear

  • Operation: EN 50110 Operation of electrical installations

  • Installation: IEC 61936-1 Power installations exceeding 1 kV AC

  • Environmental Conditions: IEC 60721-3-3 Classification of environmental conditions

NU1..jpg

Electrical Ratings

  • Rated Voltage (Ur): 24 / 36 kV

  • Power Frequency / Impulse Test Voltage (Ud/Up): 50/125 / 70/170 kV

  • Rated Frequency (fr): 50/60 Hz

  • Rated Busbar Current (Ir): 2500 A

  • Rated Feeder Current: 1250 / 2000 A

  • Rated Peak Withstand Current (Ip): 78.8 / 81.9 kA

  • Rated Short-Time Current (Ik): 31.5 kA / 3 s

  • Internal Arc Protection (AFLR): 31.5 kA / 1 s

  • Operating Temperature: -5 °C to +40 °C

Dimensions

  • Width: 650 mm (1250 A), 900 mm (2000 A)

  • Height: 2400 mm

  • Depth: 1500 mm

Dry Air Insulation Medium

Filling Pressure at 20°C (relative): 200 kPa

Minimum Operating Pressure at 20°C (relative): 180 kPa

Gas Leakage Rate: < 0.1 %/year

Pressure Relief Disc Operating Pressure: ≥ 350 kPa (gauge)

Rated Operating Sequence: O – 0.3 s – CO – 15 s – CO

NU1..jpg

According to IEC 62271:

  • Circuit Breaker Durability Class (per IEC 62271-100): M2, E2, C2

  • Disconnector Durability Class (per IEC 62271-102): M0, E0

  • Sealed stainless-steel tank for enclosed switchgear.

  • Dry air insulation medium eliminates the need for SF6 gas handling.

  • Compact size equivalent to SF6-insulated switchgear.

  • External cone plug-in system for connecting power cables and solid-insulated busbars

  • No gas work required for installation, commissioning, or future modifications.

  • Integrated pressure relief duct system.

  • Equipped with sensors for real-time monitoring of switchgear operational status.

User-Friendly Features:

  • Compact design

  • Accessible control panel

  • No SF6 – safe and climate-friendly operation

  • Front access to switchgear

Accessibility:

  • Cable compartment, current transformers (CTs), and voltage transformers (VTs) accessible from the front of the switchgear.

  • Easy cable grounding via vacuum circuit breaker ensures safe operation.

  • Metal-coated VTs, shielding, and touch-safe cables and busbars enhance safety.

Insulation Medium:

Switchgear filled with dry air insulation gas.

Characteristics of dry air:

  • Non-toxic

  • No F-gases involved

  • Climate neutral

  • Non-flammable

  • Chemically neutral

Panel Design:

  • Factory-assembled and type-tested.

  • Single-pole, solid-insulated, shielded, plug-in busbars.

  • Maintenance-free.

  • Vacuum circuit breaker.

  • Three-position disconnector for disconnection and grounding via circuit breaker.

  • Protective grounding via vacuum circuit breaker.

  • Cable connection via external cone plug-in system according to DIN EN 50 181.

  • Instrument transformers can be replaced without gas handling.

Degree of protection:

  • IP65 for all high-voltage parts of the main circuit.

  • IP3X for the switchgear enclosure.

Modular Design:

  • Current and voltage transformers mounted externally for easy maintenance.

  • Voltage transformers are metal-coated, plug-in, and disconnectable.

  • Panel replacement requires no additional gas work or movement of adjacent panels.

  • Protection and measurement systems can be integrated.

  • Low-voltage compartment is removable; busbars and instrument transformers are plug-in

  • Optional: Digital multifunction protection relay with integrated protection, control, communication, operation, and monitoring functions.

Environmental Independence:
The Nu1 consists of switchgear enclosed in a sealed tank inside an outer enclosure. This protects high-voltage components from environmental influences such as:

Harsh environmental conditions

External parameters including:

  • Salt, dust

  • Humidity, corrosion

  • Insects, rodents

  • High installation altitudes

Maintenance-Free Design:

Nuventura switchgear is enclosed in a sealed, dry-air-insulated tank, providing maintenance-free operation over its service life, ensuring:

  • Safety of personnel

  • Reliable and uninterrupted power supply

  • Sealed pressure system designed for 30 years

  • Maintenance-free under environmental conditions

  • Reduced operational costs

Automation and Digitization:

Automation systems and relays ensure timely and conditional operation of the equipment, enabling:

  • Unidirectional automation and integration into central Supervisory Control and Data Acquisition (SCADA) systems.

  • Cost-effective and efficient equipment operation based on logic functions, offering flexible and integrated solutions.

Sensor Integration (Optional):

Sensor systems are integrated within the switchgear, enabling:

  • Real-time health monitoring

  • Continuous monitoring of gas temperature, partial discharge, quality, and density

  • Savings on scheduled maintenance costs

  • Early identification of potential failures before they occur

Give a tip and encourage the author!

Recommended

Comparative Analysis of High-Voltage Load Switch Technologies
A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
12/15/2025
Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
12/11/2025
How to install a DTU on an N2 Insulation ring main unit?
DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
12/11/2025
Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
12/11/2025