Switchgear-Neutral 24kV don Grids Masu Kyau | Nu1

Edwiin
فیلڈ: Makaranta karamin kwarewa
China

Masa ista'aici da take 30-40 shekara, fitaccen inganci, kayan kwaikwayo na doka mai kyau da SF6-GIS, ba a yi amfani da gas SF6 – yana taimaka masu hawa, insulation mai dry air 100%. Nu1 switchgear yana cikin kayan kwaikwayo, yana amfani da insulation gas, tana da withdrawable circuit breaker design, kuma an samar da shi a cikin STL laboratory na musamman wajen type-test.

Standards na Amfani

  • Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for alternating current switchgear and controlgear

  • IEC 62271-200 High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

  • Circuit Breaker: IEC 62271-100 High-voltage switchgear and controlgear – Part 100: Alternating current circuit breakers

  • Disconnector / Earthing Switch: IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches

  • Current Transformer (CT): IEC 61869-2 Instrument transformers – Part 2: Current transformers

  • Voltage Transformer (VT): IEC 61869-3 Instrument transformers – Part 3: Voltage transformers

  • Insulation: IEC 60071 Insulation coordination

  • IP Code: IEC 60529 Degrees of protection provided by enclosures (IP code)

  • IK Code: IEC 62262 Degrees of protection provided by enclosures against external mechanical impacts (IK code)

  • Voltage Detection System (VDS): IEC 62271-213 Voltage detecting systems for high-voltage switchgear and controlgear

  • Operation: EN 50110 Operation of electrical installations

  • Installation: IEC 61936-1 Power installations exceeding 1 kV AC

  • Environmental Conditions: IEC 60721-3-3 Classification of environmental conditions

NU1..jpg

Electrical Ratings

  • Rated Voltage (Ur): 24 / 36 kV

  • Power Frequency / Impulse Test Voltage (Ud/Up): 50/125 / 70/170 kV

  • Rated Frequency (fr): 50/60 Hz

  • Rated Busbar Current (Ir): 2500 A

  • Rated Feeder Current: 1250 / 2000 A

  • Rated Peak Withstand Current (Ip): 78.8 / 81.9 kA

  • Rated Short-Time Current (Ik): 31.5 kA / 3 s

  • Internal Arc Protection (AFLR): 31.5 kA / 1 s

  • Operating Temperature: -5 °C to +40 °C

Dimensions

  • Width: 650 mm (1250 A), 900 mm (2000 A)

  • Height: 2400 mm

  • Depth: 1500 mm

Dry Air Insulation Medium

Filling Pressure at 20°C (relative): 200 kPa

Minimum Operating Pressure at 20°C (relative): 180 kPa

Gas Leakage Rate: < 0.1 %/year

Pressure Relief Disc Operating Pressure: ≥ 350 kPa (gauge)

Rated Operating Sequence: O – 0.3 s – CO – 15 s – CO

NU1..jpg

According to IEC 62271:

  • Circuit Breaker Durability Class (per IEC 62271-100): M2, E2, C2

  • Disconnector Durability Class (per IEC 62271-102): M0, E0

  • Sealed stainless-steel tank for enclosed switchgear.

  • Dry air insulation medium eliminates the need for SF6 gas handling.

  • Compact size equivalent to SF6-insulated switchgear.

  • External cone plug-in system for connecting power cables and solid-insulated busbars

  • No gas work required for installation, commissioning, or future modifications.

  • Integrated pressure relief duct system.

  • Equipped with sensors for real-time monitoring of switchgear operational status.

User-Friendly Features:

  • Compact design

  • Accessible control panel

  • No SF6 – safe and climate-friendly operation

  • Front access to switchgear

Accessibility:

  • Cable compartment, current transformers (CTs), and voltage transformers (VTs) accessible from the front of the switchgear.

  • Easy cable grounding via vacuum circuit breaker ensures safe operation.

  • Metal-coated VTs, shielding, and touch-safe cables and busbars enhance safety.

Insulation Medium:

Switchgear filled with dry air insulation gas.

Characteristics of dry air:

  • Non-toxic

  • No F-gases involved

  • Climate neutral

  • Non-flammable

  • Chemically neutral

Panel Design:

  • Factory-assembled and type-tested.

  • Single-pole, solid-insulated, shielded, plug-in busbars.

  • Maintenance-free.

  • Vacuum circuit breaker.

  • Three-position disconnector for disconnection and grounding via circuit breaker.

  • Protective grounding via vacuum circuit breaker.

  • Cable connection via external cone plug-in system according to DIN EN 50 181.

  • Instrument transformers can be replaced without gas handling.

Degree of protection:

  • IP65 for all high-voltage parts of the main circuit.

  • IP3X for the switchgear enclosure.

Modular Design:

  • Current and voltage transformers mounted externally for easy maintenance.

  • Voltage transformers are metal-coated, plug-in, and disconnectable.

  • Panel replacement requires no additional gas work or movement of adjacent panels.

  • Protection and measurement systems can be integrated.

  • Low-voltage compartment is removable; busbars and instrument transformers are plug-in

  • Optional: Digital multifunction protection relay with integrated protection, control, communication, operation, and monitoring functions.

Environmental Independence:
The Nu1 consists of switchgear enclosed in a sealed tank inside an outer enclosure. This protects high-voltage components from environmental influences such as:

Harsh environmental conditions

External parameters including:

  • Salt, dust

  • Humidity, corrosion

  • Insects, rodents

  • High installation altitudes

Maintenance-Free Design:

Nuventura switchgear is enclosed in a sealed, dry-air-insulated tank, providing maintenance-free operation over its service life, ensuring:

  • Safety of personnel

  • Reliable and uninterrupted power supply

  • Sealed pressure system designed for 30 years

  • Maintenance-free under environmental conditions

  • Reduced operational costs

Automation and Digitization:

Automation systems and relays ensure timely and conditional operation of the equipment, enabling:

  • Unidirectional automation and integration into central Supervisory Control and Data Acquisition (SCADA) systems.

  • Cost-effective and efficient equipment operation based on logic functions, offering flexible and integrated solutions.

Sensor Integration (Optional):

Sensor systems are integrated within the switchgear, enabling:

  • Real-time health monitoring

  • Continuous monitoring of gas temperature, partial discharge, quality, and density

  • Savings on scheduled maintenance costs

  • Early identification of potential failures before they occur

Ba da kyau kuma kara mai rubutu!

Tambayar Da Yawanci

Tambayar Gargajiya na Tekunologi na Faduwar Kirkiya na Zafi Tsari
Maimaita ce yana da shiga daga fitaccen gudummawa zuwa maimaitaccen gudummawa. Tana da karamin gudummawa mai sarrafa da take da shiga da hankali da adadin karamin gudummawa masu siffar da kuma wasu adadin karamin gudummawa masu karfi, amma bai zama da shiga da hankali da adadin karamin gudummawa masu kisan gudummawa. Maimaita suna da sauran irin, kamar maimaita masu kisan gudummawa da maimaita masu hankali.Maimaita masu kisan gudummawa da ke tattara gas: Wani irin wannan maimaita na amfani da ka
12/15/2025
Tambayar da Neman Farkon da Kudin Ƙaifiya don Yankin Ring Main Units na 17.5kV a Jami'ar Tsabta
Waɗanda yakin ƙarfin jami'a da kuma tattalin mutanen jama'a na zama, yanayin kuɗi don kula ya ƙare. Don in ba da damar yakin sauyin kula daidai, ya kamata a gina masana hanyoyin ƙarin daidai daga cikin abubuwa. Amma, a lokacin da a yi amfani da hanyoyin ƙarin daidai, ƙaramin ƙarin daidai 17.5kV suna da muhimmanci sosai, saboda haka, darajar da suka shafi tsawon ƙaramin ƙarin daidai 17.5kV ya fi haɗa da muhimmanci. A wannan lokaci, ya kamata a yi amfani da hanyoyin da suke da damar daidai wajen i
12/11/2025
Kanan da ake gina DTU a N2 Insulation ring main unit?
DTU (Distribution Terminal Unit), wanda ita ce terminal na substation a cikin sistemas na zama-zama na kashi, ita ce kayan aiki na biyu da aka shiga a switching stations, makarantun kashi, N2 Insulation ring main units (RMUs), da kuma box-type substations. Ita taka rawa daga kayan aiki na farko zuwa master station na zama-zama na kashi. RMUs mai N2 Insulation da ba suka samu DTUs ba suna iya tabbatar da master station, kuma suna gane karfin zama-zama. Idan aka fuskantar RMUs da kyau ta hanyar mo
12/11/2025
Gine-gineta Gida na Ring Main Unit na Gas-Insulated na 12kV da Ba Ta Yiwuwar Mata
1. Kasuwanci Masu Kyau1.1 Maimaita KoyarwaKungiyar Tattalin Kirki na Sinar tarayya yana taimakawa wajen kare mutane da kuma kula-kula ta hanyar tattalin kirki don in samun abin da ke cikin gasar (2030) da kuma gagarwa (2060). Dukunan gas-insulated ring main units masu kyau sun fi siffar wannan hankali. An yi koyarwa mai tsawo na 12kV integrated environmentally friendly gas-insulated ring main unit da ya haɗa teknologiyyar vacuum interrupter da three-position disconnectors da kuma vacuum circuit
12/11/2025
Aika tambaya
+86
Dauke kake saita fayil
Kwamfuta
Samun IEE Business Application
Yi amfani da IEE-Business app don samun abubuwan aikin, samun halayyin, haɗi da malamai, kuma kai tsauraran takaiddun kasoshin duka lokaci, duka wurin—dole bai karfin takamaltar hulɗin ku na alintakargida da kasuwanci.