Klima-Neutral nga 24kV Switchgear alang sa Sustainable Grids | Nu1

Edwiin
Larangan: Switch sa kuryente
China

Inaasahang panahon sa serbisyo nga 30-40 tuig, front access, kompakto nga disenyo katumbas sa SF6-GIS, walay pag-atiman sa gas nga SF6 – klima-friendly, 100% dry air insulation. Ang switchgear nga Nu1 adunay metal-enclosed, gas-insulated, nga nagpakita og withdrawable circuit breaker design, ug gipagawas na ang type-test batasan sa mga relevant nga standards, gipagtumong sa internationally recognized STL laboratory.

Compliance Standards

  • Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for alternating current switchgear and controlgear

  • IEC 62271-200 High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

  • Circuit Breaker: IEC 62271-100 High-voltage switchgear and controlgear – Part 100: Alternating current circuit breakers

  • Disconnector / Earthing Switch: IEC 62271-102 High-voltage switchgear and controlgear – Part 102: Alternating current disconnectors and earthing switches

  • Current Transformer (CT): IEC 61869-2 Instrument transformers – Part 2: Current transformers

  • Voltage Transformer (VT): IEC 61869-3 Instrument transformers – Part 3: Voltage transformers

  • Insulation: IEC 60071 Insulation coordination

  • IP Code: IEC 60529 Degrees of protection provided by enclosures (IP code)

  • IK Code: IEC 62262 Degrees of protection provided by enclosures against external mechanical impacts (IK code)

  • Voltage Detection System (VDS): IEC 62271-213 Voltage detecting systems for high-voltage switchgear and controlgear

  • Operation: EN 50110 Operation of electrical installations

  • Installation: IEC 61936-1 Power installations exceeding 1 kV AC

  • Environmental Conditions: IEC 60721-3-3 Classification of environmental conditions

NU1..jpg

Electrical Ratings

  • Rated Voltage (Ur): 24 / 36 kV

  • Power Frequency / Impulse Test Voltage (Ud/Up): 50/125 / 70/170 kV

  • Rated Frequency (fr): 50/60 Hz

  • Rated Busbar Current (Ir): 2500 A

  • Rated Feeder Current: 1250 / 2000 A

  • Rated Peak Withstand Current (Ip): 78.8 / 81.9 kA

  • Rated Short-Time Current (Ik): 31.5 kA / 3 s

  • Internal Arc Protection (AFLR): 31.5 kA / 1 s

  • Operating Temperature: -5 °C to +40 °C

Dimensions

  • Width: 650 mm (1250 A), 900 mm (2000 A)

  • Height: 2400 mm

  • Depth: 1500 mm

Dry Air Insulation Medium

Filling Pressure at 20°C (relative): 200 kPa

Minimum Operating Pressure at 20°C (relative): 180 kPa

Gas Leakage Rate: < 0.1 %/year

Pressure Relief Disc Operating Pressure: ≥ 350 kPa (gauge)

Rated Operating Sequence: O – 0.3 s – CO – 15 s – CO

NU1..jpg

According to IEC 62271:

  • Circuit Breaker Durability Class (per IEC 62271-100): M2, E2, C2

  • Disconnector Durability Class (per IEC 62271-102): M0, E0

  • Sealed stainless-steel tank for enclosed switchgear.

  • Dry air insulation medium eliminates the need for SF6 gas handling.

  • Compact size equivalent to SF6-insulated switchgear.

  • External cone plug-in system for connecting power cables and solid-insulated busbars

  • No gas work required for installation, commissioning, or future modifications.

  • Integrated pressure relief duct system.

  • Equipped with sensors for real-time monitoring of switchgear operational status.

User-Friendly Features:

  • Compact design

  • Accessible control panel

  • No SF6 – safe and climate-friendly operation

  • Front access to switchgear

Accessibility:

  • Cable compartment, current transformers (CTs), and voltage transformers (VTs) accessible from the front of the switchgear.

  • Easy cable grounding via vacuum circuit breaker ensures safe operation.

  • Metal-coated VTs, shielding, and touch-safe cables and busbars enhance safety.

Insulation Medium:

Switchgear filled with dry air insulation gas.

Characteristics of dry air:

  • Non-toxic

  • No F-gases involved

  • Climate neutral

  • Non-flammable

  • Chemically neutral

Panel Design:

  • Factory-assembled and type-tested.

  • Single-pole, solid-insulated, shielded, plug-in busbars.

  • Maintenance-free.

  • Vacuum circuit breaker.

  • Three-position disconnector for disconnection and grounding via circuit breaker.

  • Protective grounding via vacuum circuit breaker.

  • Cable connection via external cone plug-in system according to DIN EN 50 181.

  • Instrument transformers can be replaced without gas handling.

Degree of protection:

  • IP65 for all high-voltage parts of the main circuit.

  • IP3X for the switchgear enclosure.

Modular Design:

  • Current and voltage transformers mounted externally for easy maintenance.

  • Voltage transformers are metal-coated, plug-in, and disconnectable.

  • Panel replacement requires no additional gas work or movement of adjacent panels.

  • Protection and measurement systems can be integrated.

  • Low-voltage compartment is removable; busbars and instrument transformers are plug-in

  • Optional: Digital multifunction protection relay with integrated protection, control, communication, operation, and monitoring functions.

Environmental Independence:
The Nu1 consists of switchgear enclosed in a sealed tank inside an outer enclosure. This protects high-voltage components from environmental influences such as:

Harsh environmental conditions

External parameters including:

  • Salt, dust

  • Humidity, corrosion

  • Insects, rodents

  • High installation altitudes

Maintenance-Free Design:

Nuventura switchgear is enclosed in a sealed, dry-air-insulated tank, providing maintenance-free operation over its service life, ensuring:

  • Safety of personnel

  • Reliable and uninterrupted power supply

  • Sealed pressure system designed for 30 years

  • Maintenance-free under environmental conditions

  • Reduced operational costs

Automation and Digitization:

Automation systems and relays ensure timely and conditional operation of the equipment, enabling:

  • Unidirectional automation and integration into central Supervisory Control and Data Acquisition (SCADA) systems.

  • Cost-effective and efficient equipment operation based on logic functions, offering flexible and integrated solutions.

Sensor Integration (Optional):

Sensor systems are integrated within the switchgear, enabling:

  • Real-time health monitoring

  • Continuous monitoring of gas temperature, partial discharge, quality, and density

  • Savings on scheduled maintenance costs

  • Early identification of potential failures before they occur

Maghatag og tip ug pagsalig sa author

Gipareserbado

Paghiliubon sa mga Teknolohiya sa Switch sa Mataas nga Karga
Ang load switch usa ka tipo sa switching device nga anaa sa pagitan sa mga circuit breakers ug disconnectors. Iya ini simple nga arc extinguishing device nga makapadala og rated load current ug certain overload currents, apan dili makapadala og short-circuit currents. Ang mga load switches mahimong iklassipikar isip high-voltage ug low-voltage types batas sa ilang operating voltage.Solid gas-producing high-voltage load switch: Kini nga tipo gamiton ang energy gikan sa breaking arc mismo aron mak
12/15/2025
Pagsusi sa mga Sayop ug Solusyon alang sa 17.5kV Ring Main Units sa Distribution Networks
Pagkahuman sa pagpuno sa kapangyarihan sa lipunan ug ang kalidad sa kinabuhi sa mga tawo, ang pangangailangan sa kuryente mao ang nagpadayon nga nakaangat. Aron masigurado ang epektividad sa pagsulay sa sistema sa grid sa kuryente, mahimong makatuon ang pagtukod sa mga network sa distribusyon batas sa aktwal nga kondisyon. Gayunpaman, samtang operasyon sa mga sistema sa network sa distribusyon, ang 17.5kV ring main units adunay napakahalagahan nga papel, kung kayo ang impact gikan sa mga sayop k
12/11/2025
Kung paano mag-install ng DTU sa N2 Insulation ring main unit
Ang DTU (Distribution Terminal Unit), usa ka terminal sa substation sa mga sistema sa automatikong distribusyon, adunay secondary nga gamit nga gisulod sa mga switching station, distribution room, N2 Insulation ring main units (RMUs), ug box-type substations. Ito ang nag-uugmad sa primary nga gamit ug sa master station sa automatikong distribusyon. Ang mga lumang N2 Insulation RMUs nga walay DTUs dili makapag-communicate sa master station, kasagaran dili na sila mokomplyar sa mga requirement sa
12/11/2025
Diseño sa Bag-ong 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
1. Espesyal nga Disenyo1.1 Konsepto sa DisenyoAng State Grid Corporation of China aktibo sa pagpromosyon sa konservasyon sa enerhiya sa grid ug mabag-oang paglambo aron maabot ang nasodnong mga layunin sa carbon peak (2030) ug neutrality (2060). Ang mga gas-insulated ring main units nga mas magamay sa kalikasan nagrepresenta sa tendensyaning ito. Isip bag-ong 12kV na integrated environmentally friendly gas-insulated ring main unit ang gedisenyohan pinaagi sa kombinasyon sa teknolohiya sa vacuum