How do you prove that active power is the one responsible for mechanical work and not reactive power?

12/23/2024

How to Prove that Active Power is the Power that Generates Mechanical Work, Not Reactive Power

To prove that active power (Active Power, P) is the power that generates mechanical work, rather than reactive power (Reactive Power, Q), we can examine the physical principles of power systems and the nature of energy conversion. Below is a detailed explanation:

1. Definitions of Active Power and Reactive Power

Active Power P: Active power refers to the actual electrical power consumed in an AC circuit that is converted into useful work. It is associated with resistive elements and represents the conversion of electrical energy into other forms of energy, such as thermal or mechanical energy. The unit of active power is watts (W).

Reactive Power Q: Reactive power refers to the portion of electrical power in an AC circuit that oscillates between the source and the load due to the presence of inductive or capacitive elements. It does not directly perform useful work but affects the voltage and current distribution in the system, impacting its efficiency. The unit of reactive power is volt-amperes reactive (VAR).

2. Power Factor and Phase Difference

In an AC circuit, the phase difference between the current and voltage determines the ratio of active power to reactive power. The power factor cos(ϕ) is a measure of this phase difference, where ϕ is the phase angle between the current and voltage.

When ϕ=0 , the current and voltage are in phase, and only active power exists, with no reactive power. This is common in purely resistive loads.

When ϕ=0 , the current and voltage are out of phase, resulting in both active and reactive power. For inductive loads (such as motors), the current lags behind the voltage; for capacitive loads, the current leads the voltage.

3. Energy Conversion Perspective

Physical Meaning of Active Power:

Active power is the power that, through resistive elements, converts electrical energy into other forms of energy, such as mechanical energy or heat. For example, in a motor, active power overcomes the load resistance, driving the rotor to rotate and produce mechanical work.

The magnitude of active power determines the actual energy consumption in the system, making it the power directly related to performing useful work.

Physical Meaning of Reactive Power:

Reactive power does not directly perform useful work but is associated with the storage of energy in magnetic or electric fields within inductive or capacitive elements. It oscillates between the source and the load without producing net mechanical work.

The primary role of reactive power is to maintain the voltage levels in the circuit and support the establishment and maintenance of magnetic or electric fields. Although it does not directly do work, it is necessary for the stable operation of the system.

4. Example with an Electric Motor

Using an electric motor as an example, the distinction between active power and reactive power becomes clearer:

Active Power: The active power in a motor is used to overcome the load resistance, driving the rotor to rotate and generate mechanical work. This part of the power ultimately converts into mechanical energy, powering machinery such as pumps or fans.

Reactive Power: The reactive power in a motor is used to establish and maintain the magnetic field between the rotor and stator. This magnetic field is essential for the motor's operation, but it does not directly produce mechanical work. Reactive power oscillates between the power source and the motor, not converting into useful mechanical energy.

5. Law of Conservation of Energy

According to the law of conservation of energy, the electrical energy input to a system must equal the output energy (including mechanical and thermal energy) plus any losses (such as resistive losses). Active power is the portion of electrical energy that is actually consumed and converted into useful work, while reactive power is temporarily stored in magnetic or electric fields and does not directly contribute to useful work.

6. Mathematical Expression

In a three-phase AC circuit, the total apparent power S (Apparent Power) can be expressed as:

054fb58de70f23ceb66eb4f2f8ae534c.jpeg

Where:

  • P is the active power, measured in watts (W).

  • Q is the reactive power, measured in volt-amperes reactive (VAR).

Active power P can be calculated using the following formula:

8d94d9b49cd56c3c0f6405c5ce795ceb.jpeg

Reactive power Q can be calculated using the following formula:

1e52c27cd234f00b91170770914aea8b.jpeg

Here, V is the line voltage, I is the line current, and ϕ is the phase angle between the current and voltage.

7. Summary

  • Active Power is the actual power consumed and converted into useful work, such as mechanical or thermal energy. It is associated with resistive elements and can generate mechanical work.

  • Reactive Power is the power associated with inductive or capacitive elements, oscillating between the source and the load. It maintains magnetic or electric fields but does not directly perform useful work.

Therefore, active power is the power that generates mechanical work, while reactive power, although crucial for system stability, does not directly contribute to performing work. Reactive power supports the energy transfer process by maintaining the necessary magnetic or electric fields.

Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s
Vziman
08/14/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!