Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Optimizing Cable Detection and Performance in Intelligent Building Wiring Systems
The integrated wiring system of intelligent buildings, as the core carrier of information transmission, functions like a "nervous system." It connects signals such as voice, data, and images, enabling device interconnection and efficient information transmission. Cable detection is a key link to ensure system performance and information security, focusing on index detection, problem troubleshooting, and response measures.1. Core Cable Detection Indicators1.1 Appearance and Identification Verific
07/29/2025
Consult
Tip
Consult
Tip
Ensuring Stability and Safety in Communication Cable Installation for Protective Spaces
In the context of deep integration of informatization and intelligence, protective spaces, as core carriers of critical communication systems, their stability and safety directly impact information transmission reliability and infrastructure operational efficiency. Thus, analyzing core difficulties (environmental adaptability matching, electromagnetic compatibility design, construction precision control) in communication cable installation in protective spaces holds significant engineering value
07/29/2025
Consult
Tip
Consult
Tip
Transformer Simulation Analysis: Key Processes, Challenges, and Best Practices Using Finite Element Tools
1 IntroductionWhether using any finite element analysis software (such as COMSOL, Infolytica, or Ansys) for transformer simulation analysis—whether focusing on electric field, magnetic field, flow field, mechanical field, or acoustic field—the basic process is roughly the same. A true understanding of the key points in each process is the foundation for the success of the simulation analysis and the reliability of the final results.2 Basic Simulation ProcessA scientific and c
07/29/2025
Consult
Tip
Consult
Tip
Transformer Grounding & Cable Concepts Explained
Sharing of Transformer Concepts and Terminology The zero-mode impedance of a load is infinite, and its line-mode impedance is also extremely large, approximately 100 times that of the line-mode impedance of the line. The capacitance to ground of a cable is 25-50 times that of an overhead line. The free oscillation frequency of transient capacitive current: 300-1500Hz for overhead lines and 1500-3000Hz for cables. Performance requirements for an external grounding transformer: Under normal power
07/28/2025
Consult
Tip
Consult
Tip
Traveling Waves in Power Lines: Concepts & Fault Location
Traveling Waves on LinesA traveling wave on a line refers to a voltage or current wave propagating along the line; it is also defined as a voltage or current signal traveling along a conductor. Steady-state traveling wave: A traveling wave propagating along the line during the normal operation of a system, generated by the system's power supply. Transient traveling wave: A suddenly occurring traveling wave during system operation, caused by ground faults, short-circuit faults, wire breakages, sw
07/28/2025
Consult
Tip
Consult
Tip
Process Improvement for Consistent Transformer Manufacturing: Inductance Control & Performance Optimization
Given the lack of manufacturers for such transformers on the market, we design them in - house. We provide technical specs to partners, specifying materials like high - temp enameled wires.Electrical signals from downhole logging tools, transmitted via these transformers, impact formation - to - surface signal reliability. Thus, improving transformer consistency boosts signal uniformity, enhancing logging tool accuracy and our market competitiveness.Our common signal transformers are EI - type,
07/28/2025
Consult
Tip
Consult
Tip
Managing Microbial Contamination in Specialty Transformer Oil: Causes, Effects, and Treatment Methods
1 OverviewCases of transformer oil contaminated by microorganisms have been reported both domestically and internationally. Individual transformer manufacturers, user units, and research institutions have conducted specialized studies, but all focused on power transformers. This paper targets specialty transformers for specific applications (e.g., rectifier transformers for graphitization furnaces, submerged arc furnace transformers), exploring the process of microbial contamination of their tra
07/28/2025
Consult
Tip
Consult
Tip
Solving the Contradiction in Arc Suppression Coil Grounding: Damping Resistor Applications and Tuning Strategies
Contradiction PointsIn automatic tracking arc suppression coils, the adjustment precision is high, the residual current is small, and the operation is close to the resonance point.In an automatic tracking arc suppression coil grounding system, two factors must be considered: Under normal operating conditions, the long-term voltage displacement of the neutral point should not exceed 15% of the system's nominal phase voltage; In the case of a ground fault, the grounding residual current should b
07/28/2025
Consult
Tip
Consult
Tip
Design and Debugging of High-Precision Power Supply for Signal Testers Using MAX038 and BTL Amplification
1 Hardware Design of Tester Power SupplyThis device uses a standard small - signal generating device to generate small - current signals with the required frequency and phase angle. Then, through the amplifying circuit and phase - modulating circuit, the working power supply is generated.1.1 Power Frequency Sine Wave Small - Current Signal Generating DeviceThe sine wave generating circuit is mainly composed of the waveform generating chip MAX038 produced by MAXIM Corporation of the United States
07/28/2025
Consult
Tip
Consult
Tip
Advanced Turn Ratio Testing for Special Transformers: Scott, Inverse Scott, and V-v Connections
1 Error Analysis of Traditional Turn Ratio Testing MethodsThe QJ35 turn ratio bridge and other single-phase-phase-based testers all use the double-voltmeter principle. The QJ35, however, eliminates power supply fluctuation interference via bridge balance. For three-phase transformer ratio testing with a single power supply, corresponding terminals must be shorted and data converted, turning three-phase tests into independent single-phase measurements, with √3 Yd conversion based on con
07/28/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.