| Marca | ROCKWILL |
| Serie | RHD |
| Tensión máxima asignada | 362kV |
| Corriente máxima asignada | 3150~5000 A |
| Tensión asignada de soporte a impulsos de rayo | 1175/1290 kV |
| Corriente asignada de ruptura en cortocircuito | 40~63 kA |
| Frecuencia asignada | 50/60 Hz |
Description
As China's first source factory specializing in GIS tank circuit breakers.225kV, 230kV, 245kV,252kV Outdoor Dead Tank SF6 Circuit Breaker is an outdoor (50Hz) high-voltage power transmission and transformation equipment, which is used to divide and combine rated working current, fault current or conversion lines to achieve protection, control and operation of the power system.
The circuit breaker arc extinguisher adopts the principle of double air chamber and double-action self-energy arc extinguishing, with compact structure, and its technical performance has reached the international level and the domestic advanced level, which is the replacement product of the traditional compressed sulfur hexafluoride circuit breaker. The product is composed of a circuit breaker, a current transformer and an inlet and outlet bushing, and is equipped with a full spring operating mechanism, which can not only carry out split-phase operation, but also realize three-phase electrical linkage.
The product has passed all type tests according to the IEC standards, and has the characteristics of excellent breaking ability, reliable insulation, strong flow capacity, and long electrical and mechanical life.
Main feature
Excellent breaking performance:The self-energy arc extinguishing chamber can meet all terminal short circuits, breaking near area faults, out-of-step faults, out-of-phase grounding faults and line charging currents, etc., with small electrical wear and low arc voltage. The rated short-circuit current can be interrupted 20 times in a row.
Reliable insulation and strong flow capacity:SF6 gas has superior insulation performance and simple and reliable insulation structure. There are few current-carrying contact parts, few contact points, and strong flow capacity.
The structure design is unique:The arc extinguisher has simple structure, few components, light weight, small operating work, high mechanical reliability, and a mechanical life of 10,000 times; The insulation structure of the product has been optimized and designed, which greatly reduces the amount of gas, is conducive to environmental protection, and the structural design is integrated and has strong seismic ability.
Easy to install, maintain and overhaul:The overall commissioning of the factory, rapid on-site assembly, and operation with an integrated spring mechanism, no oil leakage and air leakage, no daily energy storage monitoring requirements, so it is easy to maintain.
Technical specifications
Among these, some SF6 tank circuit breakers cover non-standard voltage levels including 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV, 756kV, and 800kV, with a rated short-circuit breaking current of 50kA or 63kA, and offer customization services.
Name |
Unit |
Technical Parameters |
|
Rated Voltage |
kV |
252 |
|
Rated Current |
A |
4000 |
|
Rated Frequency |
Hz |
50/60 |
|
First - Pole - To - Clear Factor |
/ |
1.3 |
|
Rated Short - circuit Breaking Current |
kA |
50 |
|
Rated Short - time Withstand Current (Effective Value) |
kA/s |
50/3 |
|
Rated Peak Withstand Current |
kA |
125 |
|
1min Rated Power -frequency Withstand Voltage |
Phase - to - phase/Ground |
kV |
460 |
Break - port |
460(+146) |
||
Rated Lightning ImpulseWithstand (1.2/50μs Peak Value) |
Phase - to - phase/Ground |
1050 |
|
Break - port |
1050(+206) |
||
SF6 Gas (Gauge Pressure, 20 °C |
Rated Gas Pressure |
MPa |
0.60 |
Alarm Gas Pressure |
0.55±0.015 |
||
Lock - out Gas Pressure |
0.50±0.015 |
||
Rated operating sequence |
/ |
O - 0.3s - CO - 180s - CO |
|
Rated out - of - step breaking current |
kA |
12.5 |
|
Short - line - fault breaking current |
kA |
L90:45, L70:35 |
|
Out - of - phase grounding breaking current |
kA |
43.5 |
|
Rated line - charging breaking current |
A |
125 |
|
Number of breaking operations for rated short - circuit breaking current |
times |
20 |
|
Mechanical life |
times |
10000 |
|
Mechanism/operation mode |
/ |
Spring Operating Mechanism/Single - phase Operation |
|
Ambient Temperature:-30℃ ~ +40℃(standard configuration);optional -40℃ ~ +45℃ for extreme cold/hot regions (with special insulation and heating/cooling design).
Altitude:≤ 1000m above sea level(standard);for altitudes 1000m~2000m, insulation performance is enhanced by derating to ensure voltage resistance.
Relative Humidity:Monthly average ≤ 90%(at 25℃);daily average ≤ 95%;no condensation on the tank surface.
Wind Speed:Maximum sustained wind speed ≤ 34m/s(12-level wind);instantaneous gust ≤ 50m/s.
Atmospheric Conditions:Suitable for areas free of severe dust, corrosive gases(such as sulfur dioxide, ammonia), flammable gases, and conductive pollutants;for coastal or industrial areas with salt fog, optional anti-corrosion coating and sealed insulation structure are available.
Seismic Resistance:Seismic intensity ≤ 8 degrees;horizontal acceleration ≤ 0.2g, vertical acceleration ≤ 0.1g(conforms to GB/T 13540 or IEC 60068-2-57 standards).
Rainfall:Maximum rainfall intensity ≤ 100mm/h;no long-term heavy rain erosion on the upper casing.
Estructura Integral del Tanque: La cámara de extinción de arco, el medio aislante y los componentes relacionados están sellados dentro de un tanque metálico lleno de gas aislante (como hexafluoruro de azufre) o aceite aislante. Esto forma un espacio relativamente independiente y sellado, que previene eficazmente que los factores ambientales externos afecten a los componentes internos. Este diseño mejora el rendimiento aislante y la confiabilidad del equipo, haciéndolo adecuado para diversos entornos exteriores adversos.
Disposición de la Cámara de Extinción de Arco: La cámara de extinción de arco generalmente se instala dentro del tanque. Su estructura está diseñada para ser compacta, permitiendo una extinción de arco eficiente en un espacio limitado. Dependiendo de los diferentes principios y tecnologías de extinción de arco, la construcción específica de la cámara de extinción de arco puede variar, pero generalmente incluye componentes clave como contactos, boquillas y materiales aislantes. Estos componentes trabajan juntos para asegurar que el arco se extinga rápidamente y eficazmente cuando el interruptor interrumpe la corriente.
Mecanismo de Operación: Los mecanismos de operación comunes incluyen mecanismos accionados por resorte y mecanismos accionados hidráulicamente.
Mecanismo Accionado por Resorte: Este tipo de mecanismo es simple en estructura, altamente confiable y fácil de mantener. Impulsa las operaciones de apertura y cierre del interruptor a través del almacenamiento y liberación de energía en los resortes.
Mecanismo Accionado Hidráulicamente: Este mecanismo ofrece ventajas como alta potencia de salida y operación suave, lo que lo hace adecuado para interruptores de alta tensión y alta corriente.
La tasa de fuga de gas SF₆ debe controlarse en un nivel extremadamente bajo, típicamente no superior al 1% por año. El gas SF₆ es un potente gas de efecto invernadero, con un efecto invernadero 23,900 veces mayor que el del dióxido de carbono. Si se produce una fuga, no solo puede causar contaminación ambiental, sino también llevar a una disminución de la presión del gas dentro de la cámara de extinción del arco, afectando el rendimiento y la confiabilidad del interruptor.
Para monitorear la fuga de gas SF₆, generalmente se instalan dispositivos de detección de fugas de gas en los interruptores de tipo tanque. Estos dispositivos ayudan a identificar rápidamente cualquier fuga para que se puedan tomar medidas apropiadas para abordar el problema.
Durante el funcionamiento normal y los procesos de interrupción de un interruptor, el gas SF₆ puede descomponerse, produciendo diversos productos de descomposición como SF₄, S₂F₂, SOF₂, HF y SO₂. Estos productos de descomposición suelen ser corrosivos, tóxicos o irritantes, y por lo tanto requieren monitoreo.Si la concentración de estos productos de descomposición supera ciertos límites, puede indicar descargas anormales u otros fallos dentro de la cámara de extinción de arco. Es necesario realizar mantenimiento y manejo a tiempo para prevenir daños adicionales al equipo y proteger la salud del personal.