YJLW Series HV cross-linked cable

  • YJLW Series HV cross-linked cable
  • YJLW Series HV cross-linked cable

Key attributes

Brand Wone Store
Model NO. YJLW Series cross-linked cable
Rated voltage 110kV
number of core 1-core
Nominal cross-sectional area 800mm²
cable insulation structure XLPE insulation&aluminum sheath&PVC sheath
Conductor type Al-core
Series YJLW Series

Product descriptions from the supplier

Description

Overview

This productis suitable for 110-500kV power transmission and distribution system for thetransmission of electrical energy, low smoke no accounting for the flameretardant performance higher than the national standard, widely used inairports, nuclear power plants, key water control projects, high-risebuildings, Chemical, metallurgy, petroleum, traffic and other flame-retardantproperties demanding places.

Implementationstandards

66-132kV product implementationstandards: GB / T 11017 and GB / T 19666, the flame retardant properties inline with GB / T 18380 requirements;

220-500kV product implementationstandards: GB / T 18890 and GB / T 19666, the flame retardant properties inline with GB / T 18380 requirements.

Name and structure

Model

Name

Cu-core

Al-core

YJLW02

YJLLW02

Cross - linked polyethylene insulated, corrugated aluminum or welded corrugated aluminum sheath and polyvinyl chloride sheathed power cable.

YJLW03

YJLLW03

Cross - linked polyethylene insulated, corrugated aluminum or welded corrugated aluminum sheath and polyethylene sheathed power cable.

YJLW02 - Z

YJLLW02 - Z

Cross - linked polyethylene insulated, corrugated aluminum or welded corrugated aluminum sheath and polyvinyl chloride sheathed longitudinal water blocking power cable.

YJLW03 - Z

YJLLW03 - Z

Cross - linked polyethylene insulated, corrugated aluminum or welded corrugated aluminum sheath and polyethylene sheathed longitudinal water blocking power cable.

parameters

66KV cross-linked power cable

Nominal 

cross-

sectional

 area  mm²

Diameter 

of  conductor  

mm

Nominal

 thickness

 of insulation  

mm

Thickness of

 aluminum 

sheath  mm

Thickness 

of over 

sheath   mm

Approximation 

outer diameter 

 mm

Approximate Weight(kg/km)

Copper (Cu)-

PVC sheath

Copper (Cu)-

PE sheath

Aluminum (Al)-

PVC sheath

Aluminum (Al)-

PE sheath

240

18.5

13.5

2.0

4.0

78

6598

6281

5128

4811

300

20.7

13.5

2.0

4.0

80

7329

7003

5487

5161

400

23.5

13.5

2.0

4.0

83

8317

7979

5961

5623

500

26.5

13.5

2.0

4.0

86

9546

9194

6520

6168

630

29.8

13.5

2.0

4.0

89

11113

10748

7201

6836

800

33.8

13.0

2.0

4.0

93

12912

12534

7902

7524

800F

35.0

13.0

2.0

4.0

96

13614

13180

8604

8170

1000F

39.2

13.0

2.0

4.5

102

15844

15390

9557

9103

1200F

42.0

13.0

2.0

4.5

106

17641

17173

10313

9845

1400F 46.0 13.0 2.0 4.5 109 19771 19287 11190 10706
1600F 48.6 13.0 2.0 4.5 112 218.06 21308 12010 11512

110KV cross-linked power cable

Nominal 

cross-sectional 

area  mm²

Diameter

 of conductor
  mm

Nominal 

thickness 

of insulation
  mm

Thickness 

of aluminum

 sheath  mm

Thickness 

of over

 sheath  mm

Approximation 

outer diameter  

mm

Approximate Weight(kg/km)

Copper (Cu)-

PVC sheath

Copper (Cu)-

PE sheath

Aluminum (Al)-

PVC sheath

Aluminum (Al)-

PE sheath

240

18.5

19.0

2.0

4.0

90

7967

7599

6497

6129

300

20.7

18.5

2.0

4.0

91

8603

8230

6761

6388

400

23.5

17.5

2.0

4.0

92

9363

8986

7007

6630

500

26.5

17.0

2.0

4.0

94

10492

10106

7466

7080

630

29.8

16.5

2.0

4.5

98

12203

11766

8291

7854

800

33.8

16.0

2.0

4.5

102

14034

13583

9024

8573

800F

35.0

16.0

2.0

4.5

106

14542

14073

9532

9063

1000F

39.2

16.0

2.3

4.5

110

17054

16565

10767

10278

1200F

42.0

16.0

2.3

5.0

114

19136

18589

11808

11261

1400F

46.0

16.0

2.3

5.0

118

21356

20787

12775

12206

1600F

48.6

16.0

2.3

5.0

121

23434

22849

13638

13053


132KV cross-linked power cable

Nominal 

cross-sectional

 area  mm²

Diameter 

of conductor

  mm

Nominal 

thickness 

of insulation
  mm

Thickness of

 aluminum

 sheath  mm

Thickness 

of over 

sheath  mm

Approximation 

outer diameter
  mm

Approximate Weight(kg/km)

Copper (Cu)-

PVC sheath

Copper (Cu)-

PE sheath

Aluminum (Al)-

PVC sheath

Aluminum (Al)-

PE sheath

240

18.5

19.5

2.0

4.0

91

8097

7725

6627

6255

300

20.7

19.0

2.0

4.0

92

8735

8357

6893

6515

400

23.5

19.0

2.0

4.0

96

9767

9377

7411

7021

500

26.5

19.0

2.0

4.0

99

11043

10641

8017

7615

630

29.8

19.0

2.0

4.5

103

12924

12464

9012

8552

800

33.8

18.0

2.0

4.5

106

14625

14156

9615

9146

800F

35.0

18.0

2.0

4.5

109

15154

14666

10144

9656

1000F

39.2

18.0

2.3

4.5

114

17701

17194

11414

10907

1200F

42.0

18.0

2.3

5.0

118

19809

19243

12481

11915

1400F

46.0

18.0

2.3

5.0

122

22048

21459

13467

12878

1600F

48.6

18.0

2.3

5.0

125

24144

23539

14348

13743

220KV cross-linked power cable

Nominal 

cross-sectional

 area  mm²

Diameter 

of conductor
  mm

Nominal 

thickness 

of insulation
  mm

Thickness 

of aluminum 

sheath  mm

Thickness

 of over

 sheath  mm

Approximation 

outer diameter
  mm

Approximate Weight(kg/km)

Copper (Cu)-

PVC sheath

Copper (Cu)-

PE sheath

400

23.5

27.0

2.4

5.0

116

13141

12504

500

26.5

27.0

2.4

5.0

119

14515

13860

630

29.8

26.0

2.4

5.0

121

15887

15225

800

33.8

25.0

2.4

5.0

124

17683

17004

800F

35.0

25.0

2.4

5.0

127

18285

17586

1000F

39.2

24.0

2.6

5.0

130

20519

19805

1200F

42.0

24.0

2.6

5.0

134

22490

21752

1400F

46.0

24.0

2.6

5.0

137

24759

24001

1600F

48.6

24.0

2.6

5.0

140

26920

26144

1800F

52.0

24.0

2.8

5.0

144

29208

28413

2000F

55.2

24.0

2.8

5.0

148

31602

30783

500KV cross-linked power cable

Nominal 

cross-sectional

area  mm²

Diameter 

of conductor

 mm

Nominal 

thickness 

of insulation  

mm

Thickness 

of aluminum

 sheath  mm

Thickness 

of over

 sheath  mm

Approximation 

outer diameter
  mm

Approximate Weight(kg/km)

Copper(Cu)-

PVC sheath

Copper (Cu)-

PE sheath

800

33.8

34.0

2.9

6.0

150

20393

19688

800F

35.0

34.0

2.9

6.0

152

20772

20047

1000F

39.2

33.0

3.0

6.0

154

23057

22317

1200F

42.0

33.0

3.0

6.0

158

25068

24310

1400F

46.0

32.0

3.0

6.0

160

27419

26640

1600F

48.6

32.0

3.1

6.0

163

29679

28876

1800F

52.0

31.0

3.2

6.0

165

32036

31213

2000F

55.2

31.0

3.2

6.0

169

34476

33636

2200F

57.4

31.0

3.2

6.0

171

36318

35464

2500F

61.5

31.0

3.3

6.0

175

39548

38671

800

33.8

34.0

2.9

6.0

150

20393

19688

Usefeatures

1、Maximum rated temperature

Long-term maximum allowable operatingconductor temperature: 90 ℃,Maximum operating temperature under short-timeoverload: 105 90 ℃,Maximum operating temperature under short circuit (shortcircuit duration 5 s): 250 ℃

2、Installation requirements

Cable laying shall not be restrictedby drop height; the ambient temperature for laying shall not be lower than 0 90 ℃;C,and if the ambient temperature is lower than 0 90 ℃, the cable shall bepre-heated.

2.1Minimum bending radius of cable

During cablelaying: 20D0; and Permanentinstallation: 15D0.

Note: D0 is measured outerdiameter of cable.

2.2Maximum allowable axial traction for cable installation, T (radial sidepressure at bend not being considered)

Conductor: T=K x Conductor section (kg)

Aluminum sheath:T x Aluminum sheath section(kg)

Where, the coefficient K=7kg/mm2for copper conductor and 4kg/mm2 for aluminum conductor and  2kg/mm2 for aluminum sheath.

2.3Maximumallowable side pressure when cable is bent, P

P=T/R≤500(kg/m), where T is axialtraction, and R is bending radius.

Documentation Resource Library
Restricted
HV cross-linked power cable catalog
Operation manual
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.