• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


XTL-B2 Wind Turbine Generator

  • XTL-B2 Wind Turbine Generator

Key attributes

Brand Wone Store
Model NO. XTL-B2 Wind Turbine Generator
Rated power 800W
Series XTL

Product descriptions from the supplier

Description

Description

The XTL-B2 Wind Turbine Generator is a CE, ISO-certified renewable power solution. It works safely in harsh climates with no special maintenance, ideal for villas, base stations, and street lights. Sold globally, it delivers reliable independent power.

Unit characteristics

  • Security:The main stress points of the blades are concentrated in the hub, so the problems of blade falling, fracture and blade flying out are well solved.

  • Wind resistance:The horizontal rotation makes it less wind pressure and can resist super typhoons of 45 meters per second; The tail rudder adopts an automatic yaw design, with a folding tail type, which has stronger typhoon resistance.

  • Turning radius:Due to its different design structure and operating principle, it has a smaller turning radius than other forms of wind power generation, saving space and improving efficiency.

  • Power generation curve characteristics:The starting wind speed is lower than that of other forms of wind turbines, and the increase in power generation is relatively gentle, so in the range of 5~8 meters, its power generation is 10%~30% higher than that of other types of wind turbines.

  • Brake device:The blades themselves have speed protection, and can be equipped with mechanical manual and electronic automatic brakes, and in areas without typhoons and super gusts, only manual brakes need to be set.

  • Optimize design:The chassis is made of A3 steel, which is small in size, light in weight, beautiful in appearance, and low in operation. Flange installation, good strength, easy to install and maintain.

  • High utilization coefficient:The reinforced FRP wind turbine blades, with optimized aerodynamic shape design and structural design, have low starting wind speed and high wind energy utilization coefficient, increasing the annual power generation.

  • Good match:The use of permanent magnet rotor alternator for power generation effectively reduces the resistance torque of the generator, and at the same time, the use of wind turbines and generators has better matching characteristics, and the reliability of unit operation.

  • Regulating current:It can be equipped with a high-power tracking intelligent controller to effectively adjust the current.

Technical specifications:

Model

XTL-B2-700

XTL-B2-800

Rated power

700W

800W

Max power

730W

820W

Nominal voltage

24V/48V

24V/48V

Start-up wind speed

2.5m/s

2.5m/s

Rated wind speed

11m/s

11m/s

Survival wind speed

45m/s

45m/s

Top net weight

20kg

21kg

Wind wheel diameter

1.8m

1.9m

Number of blades

3/5

Blades material

Nylon fiber

Fuselage material

aluminum alloy 

Generator

Three phase ac permanent magnet generator

Control System

Electromagnet/wind wheel yaw

Yaw Mode

The wind Angle automatically

Lubrication mode

Self-lubricating 

Tower form

Cable/freestanding pylon

Working temperature

-40℃~80℃

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
  • Risk Identification and Control Measures for Distribution Transformer Replacement Work
    1.Electric Shock Risk Prevention and ControlAccording to typical design standards for distribution network upgrades, the distance between the transformer’s drop-out fuse and the high-voltage terminal is 1.5 meters. If a crane is used for replacement, it is often impossible to maintain the required minimum safety clearance of 2 meters between the crane boom, lifting gear, slings, wire ropes, and the 10 kV live parts, posing a severe risk of electric shock.Control Measures:Measure 1:De-energize th
    12/25/2025

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.