UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer

  • UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer

Key attributes

Brand Vziman
Model NO. UL 15-500kVA Oil Filled Single Phase Pad Mounted Transformer
Rated frequency 50/60Hz
Rated capacity 500kVA
Primary voltage 33kV
Series ZGS

Product descriptions from the supplier

Description

Description:

This is a single-phase oil-immersed pad-mounted transformer certified by UL, specially designed for outdoor installation. It complies with UL 1561 (Dry-Type Transformer) or UL 1562 (Oil-Immersed Transformer) standards, suitable for capacity ranges of 15-500kVA, with voltage classes covering 7.2kV-34.5kV (high-voltage side) and 120-600V (low-voltage side). Its features include:

 

  • Structural Form: Adopts Pad-Mounted (box-type floor-mounted) design with a fully sealed structure, reaching IP65/66 protection rating, and can be directly placed on concrete foundations.

  • Insulation Medium: Uses mineral oil or high-flash-point silicone oil as insulation and cooling media, with fire and explosion protection performance (complying with UL 1203 explosion-proof standards).

  • Voltage Adaptation: The high-voltage side supports multiple voltage classes such as 7.2kV, 12.47kV, 13.8kV, 25kV, 34.5kV, etc., while the low-voltage side outputs 120V/240V (single-phase three-wire) or 208V/480V/600V (three-phase four-wire).

Core Functions:

  • Voltage Conversion: Steps down medium voltage (e.g., 7.2kV) to low voltage (e.g., 240V) to meet the power demand of residential, commercial, or small industrial loads.

  • Safety Isolation: Isolates the high and low voltage sides through an oil-immersed insulation design to improve safety.

  • Overload Protection: Equipped with a temperature controller and pressure relief valve, which automatically cuts off power when the oil temperature exceeds the set value (e.g., 80°C) or internal pressure is abnormal.

  • Environmental Adaptation: Withstands harsh environments such as high temperature, humidity, and dust, suitable for long-term outdoor operation.

Typical Application Scenarios:

  • Residential Power Distribution: Provides single-phase 240V power for individual villas and residential areas, supporting high-power devices such as air conditioners and water heaters.

  • Commercial Facilities: Supplies 120V/240V power for convenience stores, small shopping malls, gas stations, etc., meeting the needs of lighting and cash register systems.

  • Small Industrial Loads: Provides power for farms and small processing plants, such as driving water pumps and small motors.

  • Renewable Energy Access: Serves as a step-up or step-down device in photovoltaic and wind power projects, adapting to distributed power generation scenarios.

Parameter:

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Choosing Vizman Distribution Transformers: Innovative Customization to Meet Diverse Power Needs
    Distribution transformers are the heart of local electricity distribution systems. They step down voltage, enabling safe and efficient power supply to homes and businesses.At Vizman Electric Power Technology Co., Ltd., we understand the critical role of distribution transformers in the energy ecosystem. That's why we specialize in manufacturing high-quality distribution transformers, providing tailored solutions to meet diverse energy needs.1.Solutions Offered by Vizman Electric Power Technology
    04/16/2025
  • SF6 Circuit Breaker Solutions in High-Voltage Power Systems: A Case Study of VZIMAN Company
    1. Challenges in High-Voltage Power Systems1.1 High-voltage power systems, as the core of power transmission, face critical challenges: Equipment Performance Limits: With increasing voltage levels (e.g., 500kV and above), traditional circuit breakers struggle to meet high breaking capacities (over 40kA) and rapid insulation recovery requirements. Overvoltage Risks: Switching capacitive loads (e.g., capacitor banks) may cause reignition, leading to dangerous overvoltages. Poor Environmental Adapt
    05/13/2025
  • VZIMAN Company SF6 Circuit Breaker Solutions for Renewable Energy Grid Integration
    1. Current Challenges in Renewable Energy Grid Integration1.1 Grid Frequency Fluctuations and Stability IssuesThe intermittency and variability of renewable energy sources (e.g., wind and solar) lead to frequent grid frequency changes. Traditional circuit breakers struggle to respond rapidly to such dynamic loads, potentially causing equipment damage or regional blackouts. For instance, during sudden drops in wind power or abrupt solar output fluctuations, the grid must isolate faults within mil
    05/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.