• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


TPE series CNC bending machine

  • TPE series CNC bending machine

Key attributes

Brand Switchgear parts
Model NO. TPE series CNC bending machine
Maximum bending force 400kn
Series TPE

Product descriptions from the supplier

Description

Efficient bending, environmentally friendly and low-maintenance – with the direct-drive servo motor, the TPE8 series increases processing efficiency by more than 1.5 times, reduces energy costs by over 70% and delivers precise bending results at the same time. Compact in design, flexible in installation and easy to maintain – for maximum productivity and sustainability.

Electric Drive System

Direct-drive servo motor offers a high response speed, enabling processing efficiency over 1.5 times higher than that of a traditional hydraulic press brake.
Compared to traditional electric press brakes, the direct-drive eliminates the need for belts. This results in higher precision.

Easy to use CNC Control

With elegant and uncomplicated design, the machine offers an intuitively user-friendly experience.
By using optimal control algorithms and motion path control, it ensures highly precise bending accuracy.

Backgauge System

Experience swift and precise backgauge positioning, delivering high-speed performance and accuracy.
Enjoy the flexibility of expanding from the standard 2-axis configuration to a 4-axis setup.
The utilization of a robust box-type structure ensures long-term stability and reliable operation.

Technical Data

Main Specification



Unit

TPE8 040/1300

TPE8 050/1500

TPE8 050/2050

Manimum bending force



kn

400

500

500

Bending length



mm

1300

1500

2050

Column interval



mm

1100

1200

1600

Depth of throat opening



mm

300

300

300

Slider stroke



mm

165

165

165

Closed height



mm

420

520

520

Slider speed without load



mm/s

160

160

160

Slider working speed



mm/s

30

30

30

Slider return speed



mm/s

160

160

160

Main motor power



kw

2x15

2x15

2x15

CNC system







Rear blocking

X Axis

Repeat

mm

+/- 0.01

+/- 0.01

+/- 0.01



Travel

mm

500

500

500



Speed

mm/s

400

400

400



Motor power

kw

1

1

1


R Axis

Repeat

mm

+/- 0.01

+/- 0.01

+/- 0.01



Travel

mm

200

200

200



Speed

mm/s

200

200

200



Motor power

kw

1

1

1


Z1, Z2, Axis

Repeat

mm

-

+/- 0.1

+/- 0.1



Travel

mm

-

350

850



Speed

mm/s

-

300

300



Motor power

kw

-

0.75

0.75

External dimensions


Length

mm

2100

2200

2900



Width

mm

1580

1650

1650



Height

mm

2900

2900

2900

Main drive type






Screw drive

Compensation mode




None


Mechanical compensation

FAQ
Q: What are the core advantages of the TPE Series CNC Bending Machine?
A:

1.Ultra-high precision bending forming

2.Efficient and intelligent processing mode

3.Full-category sheet metal adaptability

4.Stable, durable and low operation & maintenance cost

5.Safe and compliant protection design

6.Energy-saving and consumption-reducing characteristics

Q: What is the TPE Series CNC Bending Machine?
A:

The TPE Series CNC Bending Machine is a servo-hydraulic CNC device specially designed for high-precision metal sheet bending and forming, focusing on the bending processing of stainless steel sheets, aluminum sheets, carbon steel thin sheets, alloy sheets and other materials. It covers a bending force range of 80T~800T and is compatible with sheet metal of 1250mm~4000mm in bending length. Integrating core functions including dual-servo drive, automatic crowning compensation and multi-program storage, this equipment has a bending angle accuracy of ±0.08° and a repeat positioning accuracy of ±0.03mm, which can complete multi-step continuous bending of complex workpieces. It is widely used in the production and processing of electrical cabinets, switchgear, new energy equipment chassis and precision sheet metal parts, meeting the needs of both mass standardized bending and small-batch customized forming.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.