• STS Prepaid Wi-Fine Energy Meter Single Phase Wall Mounted ODM
  • STS Prepaid Wi-Fine Energy Meter Single Phase Wall Mounted ODM
  • STS Prepaid Wi-Fine Energy Meter Single Phase Wall Mounted ODM
STS Prepaid Wi-Fine Energy Meter Single Phase Wall Mounted ODM
$90.00
Model
SPM-230/5(30)-STS
SPM-230/5(32)-STS
SPM-230/5(40)-STS
SPM-230/5(45)-STS
SPM-230/5(50)-STS
SPM-230/5(100)-STS
SPM-230/5(80)-STS
Basic info
Brand Wone
Model NO. STS Prepaid Wi-Fine Energy Meter Single Phase Wall Mounted ODM
Rated voltage 230V
Rated normal current 5(100)A
Rated frequency 50(Hz)
Methods of Communication RS485
Series D123073
Product Detail

Description

STS prepaid standard meter is a media-free prepaid meter, which does not need to be recharged with IC card, magnetic card, radio frequency card, etc., and only needs to be recharged by entering the 20-digit code through the keyboard; It can also be used for power recharge, data viewing, and control management through remote communication.

Specifications

Main
Range D123073
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current  5(80) A

Rated Voltage

230V

Network Frequency 50-60Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

1000imp/kWh(LED)   1000imp/kvarh

Maximum value measured 99999.99kWh
Tariff input  Tariff
Communication port protocol DLMS
Communication port support RS485
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage ----
Mounting Mode ---
Mounting Support -----
Connections - terminals

-------

Standards

IEC62052-11:2003

IEC62053-21:2003



Environment
IP degree of protection

IP51

Relative humidity ≤85%
Ambient air temperature for operation -20…70 °C
Ambient Air Temperature for Storage --20…80 °C
Operating altitude ---
Dimensions 55.5mm*121.8mm*207mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 209mm
Package 1 Width 123mm
Package 1 Length 57mm
Package 1 Weight 1.000kg



Dimensions

企业微信截图_171858574076.png










Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!