Solid insulation cabinet lifting cabinet core - D without SF6 gas

  • Solid insulation cabinet lifting cabinet core - D without SF6 gas

Key attributes

Brand Switchgear parts
Model NO. Solid insulation cabinet lifting cabinet core - D without SF6 gas
Rated voltage 12kV
Rated normal current 630A
Series RN12-D

Product descriptions from the supplier

Description

Lift cabinet machine core - D (dedicated for solid insulated cabinets)
The lifting cabinet core - D is a core operating component specially designed for solid insulated cabinets, adapted to the switch control requirements of medium voltage power systems, focusing on safety, reliability, and precise control.
Core Features
Adopting modular design, the structure is compact and exquisite, perfectly matching the installation space and insulation protection requirements of solid insulated cabinets, and easy to disassemble and maintain.
The transmission mechanism has been precisely calibrated, with rapid response and precise opening and closing, effectively ensuring the stable operation of the switchgear.
Equipped with multiple anti misoperation designs and reliable mechanical interlocking structures, it eliminates safety hazards caused by misoperation and meets the safety standards of the power industry.
It is made of high-strength wear-resistant materials, with strong anti-aging and environmental corrosion resistance. It is suitable for long-term stable work under different working conditions, and has a long service life.
Applicable scenarios
Specially designed to match medium voltage solid insulated cabinets such as 12kV/24kV, widely used in power distribution systems such as distribution rooms, industrial plants, and new energy power stations. It undertakes the functions of lifting and opening/closing control of switchgear and is a key component to ensure power supply continuity and safety.

Overall dimensions

FAQ
Q: What advantages does solid insulated switchgear lifting core have compared with ordinary switchgear cores?
A:

It has obvious advantages in space saving, safety, environmental protection and maintenance: ① Compact lifting design: Lifting installation reduces cabinet depth by 15%~25%, adapts to narrow installation spaces (e.g., urban street cabinets, indoor compact substations), and saves land and installation costs; ② SF6-free environmental protection: Solid epoxy insulation replaces SF6 gas, no greenhouse gas emissions, no leakage risk, in line with global carbon neutrality policies; ③ High safety and reliability: Full solid encapsulation has excellent moisture-proof, dust-proof and anti-pollution performance, suitable for harsh environments (high humidity, heavy pollution, high altitude); three-position mechanical interlock prevents misoperation, ensuring operation safety; ④ Easy maintenance: Integral lifting structure allows quick disassembly and replacement without on-site debugging, reducing maintenance time and cost; ⑤ Long service life: High-strength epoxy resin and precision transmission mechanism ensure mechanical life ≥10,000 times, meeting 20+ years of operation needs.

Q: What is the core function and working principle of solid insulated switchgear lifting core?
A:

It is a key core component for 12kV/24kV solid insulated switchgear (SIS) and ring main units (RMU), with core functions: ① Realize integrated switching of circuit breaking, isolation and grounding through lifting installation structure; ② Optimize cabinet layout, reduce cabinet depth/volume, and facilitate on-site installation, maintenance and replacement; ③ Ensure safe power supply and maintenance with reliable insulation and interlock protection. Working principle: Adopt epoxy resin solid encapsulation (SF6-free) to integrate vacuum interrupter, three-position disconnector and transmission mechanism; driven by manual/electric operating mechanism, the core completes lifting positioning and contact switching, and the mechanical interlock realizes forced anti-misoperation (no closing with grounding, no opening under load), matching the maintenance-free and compact design of solid insulated switchgear.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.