• Single Phase Din Rail Electric Prepayment Meter with GPRS Communication
  • Single Phase Din Rail Electric Prepayment Meter with GPRS Communication
  • Single Phase Din Rail Electric Prepayment Meter with GPRS Communication
Single Phase Din Rail Electric Prepayment Meter with GPRS Communication
$90.00
Model
SPM-230/5(30)-3
SPM-230/5(32)-3
SPM-230/5(40)-3
SPM-230/5(45)-3
SPM-230/5(50)-3
SPM-230/5(80)-3
SPM-230/5(30)-2
SPM-230/5(32)-2
SPM-230/5(40)-2
SPM-230/5(45)-2
SPM-230/5(50)-2
SPM-230/5(80)-1
SPM-230/5(30)-1
SPM-230/5(32)-1
SPM-230/5(40)-1
SPM-230/5(45)-1
SPM-230/5(50)-1
SPM-230/5(80)-1
SPM-230/100-3DIN
SPM-230/100-2DIN
SPM-230/100-1DIN
Basic info
Brand Wone
Model NO. Single Phase Din Rail Electric Prepayment Meter with GPRS Communication
Rated voltage 230V
Rated normal current 100A
Rated frequency 50(Hz)
Methods of Communication 4G
Series D114070
Product Detail

Description

It is a single-phase two wire three modular DIN RAIL prepayment smart meter, with built-in motor relay and 4G module, automatic networking, can realize remote reading, remote recharge, remote balance clearing,  when there is overload or no credit will cut off the power automatically. At the same time, it has Bluetooth communication, which can connect with in-home-display and mobile phone for data reading and setting.

Features

  •   Recharging Token for the latest 10 times ( 20-bit code generated when recharging Token).

  •   The latest 10 events of over/under voltage, low frequency, overload, temperature, low credit.

  •   Support 4G communication, automatic networking when power on, without manual setting.

  •  The meter can store up to 31 days of 24-hour power and monthly and annual hourly cumulative data.

  •   When the load exceeds the set power threshold for more than 3 seconds, the relay will be disconnected, and the overload threshold can be set by software.

  •   Meter support terminal cover detection. When the terminal cover is opened, the indicator symbol of electricity tampering flashes.

  •  Meter has the function of detecting the imbalance of two circuits. The indicator symbol of electricity tampering flashes when the current is unbalanced between live  wire and neutral wire.

  •  The meter supports Bluetooth, RS485 local upgrade and 4G remote upgrade, which can update the firmware in time.

Specifications

Main
Range D114070
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(100)A

Rated Voltage

230V

Network Frequency 50-60Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

1000imp/kWh(LED)   1000imp/kvarh

Maximum value measured 99999.99kWh
Tariff input ---
Communication port protocol IDIS
Communication port support 4G/Bluetooth/RS485(baud rate 115200)
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage ----
Mounting Mode Clip-on
Mounting Support DIN rail
Connections - terminals

-------

Standards

DLMS/GPRS



Environment
IP degree of protection

IP54

Relative humidity ≤75%
Ambient air temperature for operation -20…75 °C
Ambient Air Temperature for Storage --20…80 °C
Operating altitude ---
Dimensions 94.2mm*54mm*72mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 74mm
Package 1 Width 56mm
Package 1 Length 96.2mm
Package 1 Weight 1.000kg



Connection Diagram


image.png


Dimensions



image.png







Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!