• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


SF6 Sleeve for GIS, SF6 gas filled sleeve for switchgear(composite, ceramic)

  • SF6 Sleeve for GIS, SF6 gas filled sleeve for switchgear(composite, ceramic)
  • SF6 Sleeve for GIS, SF6 gas filled sleeve for switchgear(composite, ceramic)

Key attributes

Brand Switchgear parts
Model NO. SF6 Sleeve for GIS, SF6 gas filled sleeve for switchgear(composite, ceramic)
Rated voltage 126kV
Rated normal current 2500A
Series T126

Product descriptions from the supplier

Description

SF6 inflatable sleeve (composite, ceramic) is mainly composed of external insulation, internal conductor, internal shielding cover, external pressure equalization ring and other components. The external insulation adopts ceramic or composite jacket, and the internal assembly includes integrated conductive rod and shielding structure. SF6 gas filled sleeve (composite, ceramic) is mainly used in GIS/GCB equipment and is an important part of power grid equipment.
Product Features
a) Innovative overall structural design, compact structure, reliable sealing performance and electric field voltage equalization; b) Innovation in electric field design technology includes current carrying design of conductive rods, internal shielding structure design, and external shielding structure design.

Product Specifications

Model Maximum Operating Voltage (kV) Rated Current (A) Creepage Distance (≥ mm) Insulator Dry Arc Distance L2 (mm) 1min Power Frequency Withstand Voltage (kV) Lightning Impulse Withstand Voltage (kV) Wet Switching Impulse Withstand Voltage (kV) Partial Discharge Level (pC) Terminal Bending Withstand Load (1min, N) SF6 Rated Pressure (20℃ Gauge Pressure, MPa) Conductive Rod Loop Resistance (≤ μΩ) Outer Insulation Sleeve Type
T126/2500-190-01 126 2500 3906 1160 230 550 / 126kV down≤5 3150 0.45 ≤30 Porcelain Sleeve
T252/3150-300-01 252 3150 9000 2260 460 1050 / 300kV down≤5 4000 0.58 ≤45 Composite
T252/4000-300-01 252 4000 9000 2260 460 1050 / 300kV down≤5 4000 0.58 ≤40 Composite
T252/3150-340-01 252 3150 7600 2200 460 1050 / 300kV down≤5 4000 0.58 ≤45 Porcelain Sleeve
T550/4000-460-01 550 4000 18755 4700 740 1675 1300 381kV down≤3 5000 0.4 ≤60 Porcelain Sleeve
T550/5000-460-01 550 5000 18755 4700 740 1675 1300 381kV down≤3 5000 0.4 ≤40 Porcelain Sleeve
T550/4000-500-01 550 4000 21000 5250 740 1675 1300 381kV down≤3 4000 0.45 ≤60 Composite
T750/5000-720-01 750 5000 40300 7540 830 1800 1425 520kV down≤5 4000 0.45 ≤60 Composite

Note: 1. The size of the wiring terminal at the upper end of the outlet sleeve, the size of the guide rod at the lower end, and the flange connection size can be customized according to engineering needs; 2. SF6 annual leakage rate ≤ 0.1%; 3. Operating temperature: -40 ℃~+50 ℃, applicable altitude: ≤ 2000m.

FAQ
Q: What scenarios and voltage/current ranges are SF6 gas-filled bushings suitable for?
A:

Widely used in GIS/HGIS substations, SF6 combined electrical appliances, and high-voltage switchgear. Voltage ranges from medium to ultra-high (up to 550kV), rated current up to 5000A, with 1min power frequency withstand voltage up to 740kV and lightning impulse withstand voltage up to 1675kV. Ideal for power grid projects, industrial distribution systems, and high-altitude/heavy pollution areas.

Q: What is the core function of SF6 gas-filled bushings (composite/ceramic)?
A:

 It acts as a key insulation and current-carrying component for GIS (Gas Insulated Switchgear) and HGIS. With SF6 gas as internal insulation (same pressure as the substation), it connects gas-insulated equipment to overhead lines, realizing safe current transmission while isolating the equipment shell from high voltage, ensuring stable operation of power systems.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.