• RWB-300 device digital microcomputer protections device
RWB-300 device digital microcomputer protections device
discuss personally
Model
RWB-300
Basic info
Brand RW Energy
Model NO. RWB-300 device digital microcomputer protections device
Rated voltage 230V ±20%
Rated frequency 50Hz
Rated current in 5A or 1A
Voltage transform Nominal 40…120 Vrms
Series RWB
Product Detail

Description:

RWB-300 device digital microcomputer protections device is applicable to the small current small resistance grounding system of 3kv and below, integrating protection, control. communication, monitoring and other function8, The device uses the ides of component programmable design to reduce the maintenance workload and spare parts, which can flexibly meat the needs of a variety of applications, and is the most ideal substitute for traditional electromagnetic relay protection.

Main function introduction:

  • Main protection relay functions: three stages phase-current protection, zero-sequence current protection, Negative sequence current protection, inverse-time protection, overload component, reclosing, frequency protection, undervoltage/overvoltage protection, zero sequence phase overvoltage protection, Motor start fast break protection, Negative sequence overcurrent, overheat protection.

  •  Control functions: circuit-breaker control.

  • Monitoring Functions: Primary currents for Phases and Zero sequence current, Primary PT Voltage, Frequency, Binary Input/Output status, Trip circuit healthy/failure, Time and date, Fault records, Event records, Switching monitoring.

  • Communication functions: Using the RS485 interface of the device passing Modbus RTU Communication protocol link to ‌SCADA system; realizable Events\Faults and Measurands viewing, executing remote command, Time synchronizing, Viewing and Changing Settings

  • Data Storage functions: Event Records, Fault Records, Measurands.

  • remote signaling remote measuring, remote controlling function can be customized address.

Technology parameters:

image.png

image.png

Device structure:

企业微信截图_17374244178007.png

Device terminal definition diagram:

企业微信截图_17374247557945.png

Installation Diagram:

ed9e8180ca8fff1b661cc4b8d1a29128(1).jpg




Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Restricted.
RWB series Microcomputer protection device
Manual English
Consulting
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!