• Intelligent Dual Power Controller
  • Intelligent Dual Power Controller
Intelligent Dual Power Controller
discuss personally
Model
RWD-LCN-SP
Basic info
Brand RW Energy
Model NO. Intelligent Dual Power Controller
Rated voltage 230V ±20%
Rated frequency 50/60Hz
Electric energy consumption ≤5W
Series RWD-LC
Product Detail

Description

With the development of society, people have higher and higher requirements for power supply reliability. In many cases, two power supplies are used to ensure the reliability of power supply, which requires a product to switch reliably between two power supplies. The intelligent dual power automatic conversion device produced by our company is mainly composed of a high-voltage vacuum circuit breaker with electric dual isolation and a dual power intelligent backup self-input controller. Applied to AC 50HZ, rated voltage 12KV, rated current up to 1250A dual power supply system, when one power failure or undervoltage occurs, the isolation switch automatically switches to the other, the whole process automatically switches to the other normal power supply. Reliable guarantee of continuity of power supply

The controller has a variety of protection functions such as short circuit, three-stage overcurrent, single-phase ground, undervoltage, reclosing and prepaid, which effectively avoids unnecessary re-supply shock when the load fails. When the common power supply fails, the switching device can automatically switch with the standby power supply to ensure reliability and safety. It is especially suitable for important places where power is not allowed, as an important electrical control device to ensure continuous power supply, it is a self-throwing self-restoring dual power automatic switching device matching with high voltage vacuum circuit breaker. The products are widely used in 10kV distribution lines in oil fields and mines, and 10kV lines in industrial and mining enterprises to ensure real-time power supply of important loads. It has the characteristics of small footprint, small investment, convenient debugging and maintenance, and is an ideal switchgear for realizing power supply automation.

Support communication methods: wireless (GSM/GPRS/CDMA), Ethernet, WIFI, optical fiber, power carrier, RS232/485,RJ45, etc., and can access other station equipment (such as TTU, FTU, DTU, etc.).

Main function introduction

1. Protection relay functions:

AST    Double line Protection,

49     Thermal Overload (Over load), 

50 Three-section of Overcurrent (Ph.OC),

50G/N/SEF Sensitive Earth Fault (SEF),

27/59 Under/Over Voltage (Ph.OV/Ph.UV), 

51C Cold load pickup (Cold load).

2. Supervision functions:

60CTS CT Supervision,

60VTS VT Supervision. 

3. Control functions:

79 Auto Reclose,

86 Lockout>>>>>>.

circuit-breaker control.

4. Monitoring Functions: 

1) Primary currents for Phases and Zero sequence current,

2) Primary PT Voltage,

3) Frequency,

4) Binary Input/Output status, 

5) Trip circuit healthy/failure,

6) Time and date,

7) Fault records,

8) Event records.

5. Data Storage functions:

1) Event Records,

2) Fault Records,

3) Measurands

Technology parameters

 paramete.png

Device structure

RWD-LC-尺寸.png

双电源控制器的应用方案.png

About customization

The following optional functions are available: Upgrade SMS Function. Upgrade RS485/RS232 socket.

For detailed customization, please contact the salesman.

Q: What is a high voltage dual power switch?

A: The high-voltage dual power switch is a device used to automatically switch between two high-voltage power supplies. When one power supply fails (such as power failure, abnormal voltage, etc.), it can quickly switch the load to another normal power supply to ensure the continuity of power supply.

Q: Where is it mainly used?

A: In hospitals, data centers, large factories and other places where continuity of power supply is highly required. For example, during hospital surgery, a sudden power outage may endanger the patient's life, and the use of high-voltage dual power switch can avoid this situation.

Q: How fast does it switch?

A: Generally speaking, the switching time can reach the millisecond level, which can minimize the time of load power failure and avoid damage to the equipment.

Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Restricted.
Intelligent Dual Power Controller
Manual English
Consulting
FAQ
Q: What is fixed-time overcurrent protection
A:
The action time of fixed-time overcurrent protection is fixed, independent of the magnitude of the fault current. When the current in the circuit exceeds the set value, after a pre-set fixed time, the protection device operates. This type of protection is simple and reliable, and is suitable for some occasions where the protection action time is not required to be high.
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!