The smart brain for your MV automatic recloser — embedded protection, wide-range sensing, multi-shot reclosing, local control and SCADA-ready communication in a single compact controller. Built for 11–38kV distribution automation.

11–38kV
Distribution class
0.5 A
Wide-range sensing
1–4 shots
Programmable reclosing
SCADA
RTU/DNP3/IEC 60870

What is an automatic recloser controller?

The controller is the protection and control unit mounted on (or connected to) an MV automatic recloser. It senses line current and voltage, decides when to trip and reclose, and reports to the control centre.

An automatic recloser controller continuously monitors the distribution line and, on a transient fault, commands the recloser to trip and automatically reclose through a programmed sequence of shots. This restores supply for most overhead faults in under a second without a crew. The controller also provides local/remote control, event logging, fault recording and SCADA/DNP3 or IEC 60870 communication, making it the core of modern distribution automation.

Embedded protection

Overcurrent, earth-fault and directional elements tuned for MV overhead feeders.

Programmable reclosing

Multi-shot reclosing with configurable dead time and fast/slow shot sequence.

SCADA ready

DNP3 / IEC 60870-5-104 communication with remote trip, close and settings.

Advantages for distribution automation

Faster restoration

Transient faults clear automatically — typical SAIDI improvement for overhead feeders.

Remote control

Operate and reconfigure the recloser from the control centre, no field visit.

Condition data

Continuous waveform, fault and operation records for asset analytics.

DER friendly

Bidirectional fault detection supports distributed generation on the feeder.

Flexible comms

RS232/485, optical, Ethernet and cellular options for any topology.

OEM / ODM

Matched to ROCKWILL reclosers or retrofitted to third-party units.

Typical specifications

RWK-65尺寸图-Model.png

Representative values; the certified datasheet is prepared on request — contact us.

Parameter Typical value
Nominal system voltage 11kV / 12.47kV / 24kV / 33kV / 38kV
Current sensing range 0.5 A to 1,000 A (CT input)
Protection functions Phase/ground overcurrent, directional, over/under voltage
Reclosing sequence 1–4 shots, programmable fast/slow dead time
Communication DNP3, IEC 60870-5-104, Modbus; RS232/485, Ethernet, cellular
Local control Open/close pushbuttons, trip indicator, live LED
Recording Event log, oscillography, fault reports
Power supply CT-powered with battery / external 12/24/48 Vdc
Enclosure IP54 weatherproof control cabinet / pole-mount
Standard IEC 62271-111 / ANSI C37.60 (application)
Category Item RWK-651HBV RWK-652HBV
Model & system Model RWK-651HBV RWK-652HBV
Version V2.3.0-FA  
Type of operating mechanism Spring mechanism type Magnetic Actuator type
System language English Russian
PC software language Chinese Simplified / English / Russian / Spanish  
Power Rated working voltage 230V ±20%  
Rated frequency 50Hz/60Hz  
Electric energy consumption ≤5W  
Power management I/O I/O configuration 1 DC voltage measurements
 
1 battery undervoltage alarm
 
1 battery active state
 
1 battery active control
 
I/O rated Voltage DC24V  
I/O current consumption ≤10mA  
AI parameters Current transform quantity 3 phase current + 1 earth current  
Rated current in 5A or 1A  
Voltage transform quantity 1 voltage transform  
Nominal 40…120 Vrms  
Voltage sensor quantity 6 Voltage sensor  
Nominal 0…60 Vrms  
Protection relay and measurement accuracy Current protection (secondary side) 0.05~50A ≤±3%
Zero-sequence current protection (secondary side) 0.02~10A ≤±1%
Voltage 10~280V ≤±5%
Protection performance parameters Event resolution 2ms
Quick-break export time Under the input of 1.2In magnification, the whole group action time is less than 40ms
Protect export time error ≤1%
Switching value parameters Number of DI group1 interfaces 1COM&10DI
DI group1 Rated voltage DC24V
DI group1 current consumption ≤2mA
switching value resolution Minimum 2ms
Number of DI group2 interfaces 1COM&8DI
DI group2 Rated voltage DC24V
DI group2 current consumption ≤2mA
switching value resolution Minimum 2ms
Number of DO group1 interfaces 2 groups NO
DO group1 Rated voltage 230VDC
DO group1 Rated current 120A
Number of DO group2 interfaces 2 groups NO and NC
DO group2 Rated voltage 250VAC or 30VDC
DO group2 Rated current 5A(AC)/3A(DC)
Number of DO group3 interfaces 8 groups NO
DO group3 Rated voltage 250VAC or 30VDC
DO group3 Rated current 5A
Communication I/O parameters RS232 port 2*DB9 120Mbps
RS485 port 2*3PIN Terminal 10Mbps
Ethernet port 2*RJ45 100Mbps
Debug port 1*USB type-b 10Mbps
Update port 1*RJ45 10Mbps
EMC technology parameters Insulation resistance ≥10MΩ
Voltage mutation 100%, 0.5s
High-frequency interference (series mode) 1.5kVP, 1min
High-frequency interference (common mode) 2.5kVP, 1min
transient pulse 4.0kVP, 1min
inrush current interference 4.0kVP, 1.2/50μs
electrostatic discharge 8kV
power frequency magnetic fields 100A/m
Damping oscillating magnetic field 100A/m
Power frequency withstand voltage 2.5kV, 1min
Lightning rush voltage 5kV, 1.2/50μs
enforce standards DL/T 721-2000 class IV
Working environment Ambient temperature -25℃ ~ +70℃
Storing temperature -40℃ ~ +70℃
Ambient humidity 5% ~ 100% (Non-congealing)
Rate of ambient temperature change <25℃/h
Altitude range -100~3000m
Machine case parameters weight > 10kg
size 575420245mm (Lead acid battery)
 
635420245mm (Lithium ion battery)
Class of protection IP55

Frequently asked questions

It monitors the MV line, trips the recloser on a fault, and automatically recloses through a programmed sequence. This clears most transient faults — like lightning or tree contact — without a field crew, restoring supply automatically.

The controller runs a configurable sequence of shots — typically 1 to 4 — with set dead times. After the first shots, it delays longer to let the fault burn out; if it persists after the last shot, it locks out and reports.

Yes. The controller supports DNP3 and IEC 60870-5-104 over RS232/485, Ethernet or cellular, giving the control centre remote trip, close, status and settings access.

It is matched to ROCKWILL reclosers, but can be configured for many third-party MV reclosers via standard CT/signal interfaces under OEM/ODM.

Yes. We manufacture the automatic recloser controller under OEM/ODM with your label, firmware settings and documentation.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register