420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

420 units of 11kV auto-reclosers with vacuum interrupters, magnetic actuators, and SCADA integration are upgrading Dhaka's distribution grid.

RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd.
Add us on Google

01 General Overview: Dhaka 11 kV Distribution Grid Upgrade

1.1 Project Background

Bangladesh is currently undergoing a period of rapid economic and industrial development, and the growing demand for electricity has placed immense pressure on the local distribution networks. However, the country's existing 11 kV backbone distribution lines are facing severe equipment aging issues. The original switchgear suffers from serious mechanical wear, resulting in not only high failure rates but also sluggish response times. Furthermore, due to historical reasons, the network is a mix of equipment from various brands with incompatible communication protocols. This has led to a severe "information silo" phenomenon, making it impossible for the background SCADA system to achieve global, unified monitoring.

To completely resolve these pain points in the June 2024 Dhaka distribution network upgrade project, Rockwell Energy Company acted as the core equipment manufacturer. We customized and delivered 420 units of 11 kV intelligent Automatic Circuit Reclosers in bulk to the state-owned utility of Bangladesh. This comprehensive replacement of retired equipment aims to reshape the power supply reliability and automation level of the local backbone distribution network.

1.2 Technical Specification

Tailored to the actual operating conditions of the 11 kV distribution network in Bangladesh, the equipment delivered utilized high-standard main circuit parameter designs to ensure powerful breaking capacity and high insulation withstand levels.

Parameter

Specification

Equipment Type

Intelligent Automatic Circuit Recloser

Rated Voltage

11 kV

Maximum Equipment Voltage / Insulation Level

15 kV

Rated Current

630 A

Rated Short-Circuit Breaking Current

16 kA

Rated Lightning Impulse Withstand Voltage

95 kV BIL

Rated Frequency

50 Hz

Arc Extinction

Vacuum Interrupter (VI)

Operating Mechanism

Single-Coil Magnetic Actuator

Communication Protocols

IEC 60870-5-104, DNP3.0, Modbus RTU/TCP

1.3 Drawings

We provided the customer with a comprehensive set of engineering drawings, including dimensional drawings of the recloser main unit, internal electrical schematic diagrams of the control box, and standardized mounting bracket hole layouts. This not only offered precise data support for early-stage scheme reviews but also laid a solid foundation for standardized on-site construction.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

02 Manufacturing Quality for 11 kV Intelligent Reclosers

The core manufacturing processes for this batch of equipment strictly adhere to international standards, aiming to build a highly reliable hardware foundation adaptable to harsh tropical climates.

2.1 Vacuum Interrupter (VI)

The main circuit adopts a high-performance Vacuum Interrupter (VI), completely eliminating the environmental hazards associated with greenhouse gases like SF6. At a 16 kA short-circuit current, the equipment fully complies with the rated short-circuit breaking capacity requirements stipulated by IEC 62271-111; at the rated operating current, it achieves an extremely long electrical operational lifespan, perfectly meeting the demanding requirements of frequent reclosing in distribution networks.

2.2 Single-Coil Magnetic Actuator

To thoroughly resolve the chronic issue of "refusal to operate/maloperation due to mechanical wear" inherent in old spring mechanisms, the equipment is equipped with an advanced single-coil magnetic actuator. This mechanism utilizes permanent magnets to maintain the open/close states and features very few moving parts, completely eliminating complex latches and mechanical transmission chains. This minimalist design elevates the mechanical lifespan to an extremely high level, achieving truly "maintenance-free" operation.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

2.3 Intelligent Controller & High IP Enclosure

  • Intelligent Brain: A built-in dedicated microcomputer controller for the recloser features a powerful advanced protection matrix (including 3-stage overcurrent, phase/zero-sequence fast and slow curve TCC, and Sensitive Earth Fault SEF protection). It also deeply integrates with protocols like IEC 60870-5-104 (IEC 104) and DNP3.0, breaking down communication barriers.
  • Physical Protection: Bangladesh experiences high temperatures and humidity year-round. Tailored to the tropical monsoon climate of this project, the delivered recloser main body is configured with an IP65 protection rating (upgradable to IP67). The control cabinet utilizes a high IP54 protection rating (standard is IP43) and has undergone C4-level heavy-duty multi-layer anti-corrosion coating, compliant with ISO 12944 for industrial/coastal environments (customizable to C5), effectively preventing the ingress of rainwater, salt spray, and dust.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

2.4 Final Assembly

In the final assembly stage, the Vacuum Interrupter (VI), magnetic actuator, high-precision current/voltage sensors, and intelligent control box are precisely integrated on a standardized, dust-free production line. Digital torque wrenches are used for torque control during assembly to ensure highly consistent mechanical characteristics for every single recloser.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

03 Rigorous Testing: Ensuring IEC & IEEE Compliance

Rockwell Energy Company strictly relies on the ISO 9001 Quality Management System and ISO 14001 Environmental Management System for full-process production control. Before mass delivery, this series of intelligent automatic reclosers passed comprehensive Type Tests at an internationally authoritative third-party laboratory, fully complying with the dual standards of IEC 62271-111 / IEEE C37.60. These tests included the 95 kV BIL lightning impulse withstand voltage test and the 16 kA short-circuit breaking test, fully verifying the equipment's design margins under extreme conditions.

For the 420 units delivered in this project, rigorous Routine Tests were 100% executed before leaving the factory to ensure the delivery quality of each unit:

  • Insulation and Withstand Voltage Tests: Power frequency withstand voltage tests were performed on both the primary and secondary circuits to verify insulation consistency under mass manufacturing.
  • Mechanical Operation and Characteristic Tests: Continuous mechanical action cycle tests were conducted on the single-coil magnetic actuator to precisely verify its operation time, synchronicity, and mechanical stability.
  • Secondary Circuit and Functional Joint Tests: A professional test platform was used to conduct secondary circuit verification and full-function joint commissioning on the control box. This included verifying advanced protection logic actions and performing deep data interaction testing of multi-protocol communications (e.g., IEC 60870-5-104, DNP3.0), ensuring the equipment could seamlessly integrate into the customer's SCADA system upon site arrival.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

04 Packing and Secure Shipping to Bangladesh

For the cross-border delivery of large batches of precision power equipment, we formulated the highest-standard safe logistics plan.

4.1 Packing

Considering the high humidity and salt spray erosion during transit through tropical waters, both the recloser main body and control box were vacuum-sealed in thickened moisture-proof bags with an ample amount of industrial desiccant placed inside. The exterior utilized heavy-duty, fumigation-free solid wood crates that meet international export standards, providing robust physical support.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

4.2 Shipping

During the ocean freight container loading process, customized anti-shock lashing straps were used for rigid securing, and anti-tilt and anti-shock labels were affixed to the exterior of key wooden crates. This end-to-end transportation plan ensured that the 420 units of equipment arrived completely intact at the customer site after enduring long-distance ocean voyages and inland transportation bumps in Bangladesh.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

05 Installation and SCADA Integration Summary

5.1 Site Installation

The on-site deployment of the equipment was extremely efficient. The recloser adopts a standardized pole-mounting bracket design, and the connection between the control box and the main body uses a plug-and-play, heavy-duty aviation plug cable. This eliminates complex on-site wiring and secondary commissioning, drastically shortening the installation and outage time for a single unit.

420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade

5.2 Summary

The successful grid connection of 420 units of 11 kV intelligent automatic reclosers completely broke the long-standing "communication silo" in the Bangladesh distribution network. The equipment relies on the zero-maintenance architecture of the "Vacuum Interrupter (VI) + Single-Coil Magnetic Actuator." Combined with the millisecond-level advanced protection matrix and multi-protocol plug-and-play technology, it reduces traditional line fault troubleshooting and isolation times from hours down to milliseconds. This qualitative leap in fault handling efficiency will significantly improve the System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Index (SAIFI) performance of the regional distribution network, laying a solid physical and data foundation for the Bangladesh grid to comprehensively move towards automation and self-healing.

06 Lifecycle Services

As a senior power equipment manufacturer with global delivery capabilities, Rockwell Energy Company not only provides high-quality physical equipment but is also committed to offering customers systematic service guarantees covering the equipment's entire lifecycle:

  • Technical Consultation and Customization: Providing professional grid protection logic customization and protocol docking schemes in the early stages of the project.
  • Spare Parts Guarantee: Establishing a dedicated spare parts warehouse for customers in Bangladesh to ensure a rapid-response supply of core wearing parts such as vacuum interrupters and controller plug-ins.
  • Software Iteration and Upgrades: As the customer's SCADA system evolves, providing free underlying software upgrade services for the controller to continuously optimize the communication protocol stack and protection algorithm curves.
  • Long-Term Technical Support: Providing 24/7 remote diagnostic support and regular localized technical training for engineering personnel, ensuring the grid O&M team always masters the latest equipment debugging and maintenance skills.

For more details, please feel free to contact us. We are ready to provide you with exclusive solutions and highly efficient response services!

Deployed Equipment

Related Solutions

  • Recloser controller Intelligent insulation and dehumidification upgrade solution
    I.Background of the Proposal1. Countries or regions such as Indonesia, Malaysia, Singapore, the Philippines, Thailand, Vietnam, southern India, Bangladesh, Sri Lanka, Central America, Caribbean countries, coastal areas of Brazil, Colombia, and equatorial coasts of Africa are prone to the following hazards during long-term operation of controllers due to high temperatures, humidity, and salt spray: Internal condensation, circuit board moisture and short circuit Terminal oxidation and poor con
  • Distributed Fault Precise Localization System Solution for Transmission Lines
    One-sentence conclusionThis solution deploys dual-mode distributed fault location terminals—both contact-based and non-contact-based—for transmission lines above 35 kV, with intervals ranging from 5 to 30 km. It achieves a fault location accuracy of ≤ ±100 m, a segment-level positioning reliability of ≥ 99%, and an identification accuracy for lightning-induced versus non-lightning-induced faults exceeding 95%. As a result, fault patrol time is reduced from hours to minutes.I. Industry Pain Point
  • Distribution Automation — The Evolution from Reactive Repair to Active Self-Healing Smart Grids
    1. Industry Challenge: The "Physical Blind Spots" of Traditional Distribution Networks1.1 The "Manual Search" Era of Fault LocationIn traditional distribution networks, when a 10kV feeder trips, maintenance crews must patrolkilometers of line pole-by-poleto visually locate the fault point. This outdated operational model directly results in three critical consequences:Degraded SAIDI Metrics: Average outage durations typically exceed 120 minutes.Wildfire Risk: High-impedance ground faults (e.g.,
  • Remote OM Technical Solution for South Africa Distribution Lines - RWZ-1000 Cloud-Based Monitoring
    Technical Framework for Digitally Reimagining Power Grid OM in South AfricaShifting from "post-fault repair" to "predictive maintenance," reshaping the operation and maintenance processes of the distribution network through digital means.Applications: Unmanned substations, cross-regional long-distance transmission lines, and high-risk operational zones.Product Portfolio: RWZ-1000 intelligent monitoring system and RW8000 cloud management platform.Standards: IEC 60870-5-104, IEEE 1547, and NRS 048
  • Communication-Free Feeder Automation: Recloser and Drop-Out Sectionalizer Coordination for Grids Without Communication Infrastructure
    Target markets: Africa · Southeast Asia · South America · South Asia | Products: recloser + drop-out sectionalizerDistribution Reliability Challenges in Communication-Constrained NetworksIn Nigeria, a rural distribution feeder trips an average of 8 times per month. Each outage — from the moment the substation protection operates until supply is restored — typically lasts 2 to 5 hours, and overnight outages and outages during the rainy season are routine.When a fault occurs, maintenance crews mus
  • Smart O&M for Recloser Controllers: Reducing Troubleshooting Time from 6 Hours to 30 Minutes
    Many recloser controllers currently in operation suffer from low intelligence; they lack real-time status monitoring, diagnostic traceability, and often have cumbersome user interfaces. This makes troubleshooting slow and labor-intensive, driving up O&M costs. Based on a real-world urban distribution case, we have developed a specialized solution to resolve these operational bottlenecks.I. Pain Points: High Costs and Slow Response TimesCore Issues No Status Monitoring: Inability to track tem
  • Frequent malfunctions and failures to trip in rural grid recloser controllers? A radical reliability solution achieves zero faults year-round.
    Technical Solution: Upgrading Recloser Controllers to Meet New Energy Integration and Grid Automation RequirementsAs renewable energy sources (such as solar and wind power) become increasingly prevalent, older recloser controllers—with their simplistic functions—are failing to meet the demands of modern power grids. This often leads to frequent malfunctions and power supply instability. Based on real-world applications, we have developed this comprehensive solution to resolve these adaptation ch
  • Recloser Controllers Communication Upgrade: Enhanced Protocol Compatibility and Stability for Faster Grid
    As distribution grid automation matures, recloser controllers must "communicate" seamlessly with master stations, FTU terminals, and ring main units (RMUs) to quickly isolate faults and restore power automatically. However, many legacy controllers suffer from "communication barriers" or "unstable connections," hindering grid automation. Based on a real-world county-level grid case, we have developed this communication upgrade solution to eliminate these hurdles.I. Pain Points: Protocol Incompati
  • Technical Solution: Enhancing Recloser Controllers Reliability for 10-35kV Mid-Voltage Grids
    The recloser controller serves as the "protective brain" of 10-35kV medium-voltage distribution networks. Its reliability directly determines whether a line trips unnecessarily, fails to trip when needed, or causes large-scale blackouts. Currently, many devices suffer from poor material quality and oversimplified designs, leading to frequent malfunctions (nuisance tripping) or failure to operate, which severely compromises power safety. Based on a real-world rural grid case, we present a special
  • Full-Lifecycle Management of Distribution Grid recloser controllers: A Five-Stage Synergistic Solution to Five Core Pain Points
    The recloser controller is the "chief steward" of 10-35kV medium-voltage distribution networks. Standardized management across every phase—from model selection and manufacturing to installation, daily O&M, and final decommissioning—directly determines whether the power supply remains stable and if the grid can achieve rapid self-healing.This solution focuses on the "lifespan" of the controller, providing simple, actionable, and cost-effective measures for each stage. It achieves efficient fu
  • Adapting to Extreme Environments: 4D Customization for High Altitude, Cold, Salt Spray, and Pollution to Boost Recloser Controllers Reliability
    Most recloser controllers are installed outdoors, facing year-round exposure to high altitudes, extreme cold, coastal salt spray, and industrial pollution. However, many current devices use a "one-size-fits-all" standard design without optimization for these harsh conditions, leading to frequent failures and premature breakdowns. Based on a real-world high-altitude case, we have developed this specialized solution to solve the "environmental maladaptation" of equipment in extreme conditions.I. P
  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
  • Coordinated Application Scheme for Reclosers and Drop-Out Type Sectionalizers
    1. Executive SummaryThis solution proposes a fault-isolation architecture based on the coordinated operation of automatic reclosers and drop-type sectionalizers, featuring “local control without communication.” It is particularly suited for rural and suburban feeders in 15 kV overhead distribution networks in developing countries and regions overseas—areas where SCADA infrastructure is weak, communication maintenance costs are high, and enhancing power supply reliability is the primary objective
Leave your contact information to receive the full technical white paper, equipment list, and energy efficiency report for this case.

Comments

Share your question or perspective
WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register