Distribution automation systems solutions

RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd.

What are the difficulties in overhead line operation and maintenance?

Difficulty one:
Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".
Difficulty Two:
Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical means.
Difficulty Three:
The fixed value of line protection cannot be adjusted remotely,and thefield maintenance work is heavy.
Difficulty Four:
Fault message is not pushed in time which lengthening the fault outagetime and impacting on power supply quality and company's reputation.
Difficulty Five:
The line power supply load curve can not be controlled timely and effectively,which leads to the irrationality of the protection setting.

Five core functions of Distribution automation systems

①Fault Isolation
Fast isolation of fault section,reduce the scope of power cuts,avoid overridetrip and expand the outage scope.
②Fault location
Locate fault section accurately,shorten the time of troubleshooting.
③Alarm Push
Push the fault type,fault time and switch position to the responsible person'smobile phone and monitoring center in time.
④Monitoring Analysis
Real-time monitoring of load current,voltage,switch state,three-phaseunbalance,overload abnormal alarm,viewing the historical data statistics,analyzing historical load and setting reasonable value.
⑤Setting Value Remotely
Adjusting protection values remotely for saving times and efforts.

What is the effect of  system implementation?

Before installing the system,a power supply bureau indicated thatwhen the line has a fault,it have to take about half an hour to one hour forthe fault information to be fed back to the operation and maintenancedepartment.

At the same time,troubleshooting is also a big pain point.You have to take much efforts to find the fault point and it even takes youabout one day to troubleshoot sometimes(especially search afteroverride trip).During the period,you will also get lots of complaints frompeople.

Since the implementation of system,it can push faultinformation (location,fault type and time)in time and reduce the time fortroubleshooting greatly.Besides,the reasonable protection setting alsoreduced override trip and outage range.

In brief,system improves the reliability of power supply,the quality of power grid and the satisfaction of users.Meanwhile,therewill be a complete load record for forecasting load accurately and makingthe expansion plan of distribution network more targeted.

Common faults of 10-35 kV overhead lines

①Single-phase grounding is the most common fault of power distribution system,which mostly occurs in wet and rainy weather.It is caused by manyfactors,such as tree barrier,single-phase breakdown of insulator on distributionline,over-load burning or oxidative corrosion shedding at wire junction,single-phase broken line and so on.

②Interphase short circuit fault refers to the fault that two points of differentpotential in the line are short-connected by the conductor,or the insulationbetween them is broken,causing the line to fail to work normally.According todifferent situations,short circuit fault can be divided into metallic short circuit andnon-metallic short circuit;single phase short circuit and polyphase short circuit.

Fault handling

There are two modes for feeder terminal to deal with single-phasegrounding fault which is warning or tripping.

When the feeder terminal samples the single-phase grounding faultcurrent,the terminal will carry warning or trip circuit breaker according to thepre-selected mode.At the same time,pushing the fault information(location,fault type and time)to the relevant personnel of operation and maintenancedepartment,so that the responsible personnel can grasp the fault information atthe first time and take actions.

When the feeder terminal samples the interphase short circuit current,theterminal will let the circuit breaker act quickly to isolate the fault,so as to avoidoverride tripping to expand the power cut range.Meanwhile,pushing the faultinformation (location,fault type and time)to the relevant personnel of operationand maintenance department,so that the responsible personnel can grasp thefault information at the first time and take actions.

Deployed Equipment

Case Studies

  • 420 Units of 11 kV Automatic Reclosers for Dhaka Grid Upgrade
    01 General Overview: Dhaka 11 kV Distribution Grid Upgrade1.1 Project BackgroundBangladesh is currently undergoing a period of rapid economic and industrial development, and the growing demand for electricity has placed immense pressure on the local distribution networks. However, the country's existing 11 kV backbone distribution lines are facing severe equipment aging issues. The original switchgear suffers from serious mechanical wear, resulting in not only high failure rates but also sluggis
  • RW Energy Colombia PV Plant 35 kV Recloser Controller Project Case Study
    Facing the frequency fluctuation and grid connection challenges of Colombia’s low-inertia photovoltaic power grid, this solution leverages customized recloser control and optimized frequency protection technologies to precisely adapt to the local 60Hz grid standard. It effectively addresses grid fluctuation issues under complex grid connection conditions, delivering a highly reliable and strong anti-interference grid protection solution for photovoltaic power plants and ensuring their stable and
  • RW Energy Xinjiang Bazhou Large-scale Data Center 6 kV Industrial Grid Intelligent Power Distribution Upgrade Case Study
    Focusing on the high-reliability power supply demands of data centers, this project upgrades the 6kV industrial intelligent power distribution system. It enhances anti-sandstorm and wide-temperature environmental adaptability, integrates rapid protection and remote intelligent operation and maintenance technologies, stably supports high-density computing loads, and empowers the intelligent transformation of power grids in western computing hubs.01 Project Overview1.1Project BackgroundBayingolin
  • RW Energy Multi Country SMS Based Auto Recloser Controller Case Study
    Breaking the communication bottlenecks in remote areas worldwide, this solution takes SMS communication as its core innovation and develops recloser controllers adaptable to multiple countries and diverse climates. Free from reliance on 4G networks, it enables rapid fault early warning and remote operation & maintenance management, helping various regions resolve distribution network operation challenges in remote areas and inject intelligent momentum into global rural power grid upgrading.0
Leave your contact information to receive the full technical documentation and a free consultation from our engineers.

Comments

Share your question or perspective
WhatsApp
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register