RNVD-12 SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism

  • RNVD-12 SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism

Key attributes

Brand Switchgear parts
Model NO. RNVD-12 SF6 gas filling cabinet electric spring operating mechanism circuit breaker mechanism
Rated voltage 12kV
Series RNVD

Product descriptions from the supplier

Description

The RNVD-12 SF6 circuit breaker operating mechanism is a supporting equipment suitable for the opening and closing operations of circuit breakers in inflatable high-voltage ring main units. This series of circuit breaker mechanisms uses tension spring midpoint control to close the circuit breaker, and compression spring energy storage control to open the circuit breaker. This product has a reclosing function and an interlocking function when used in combination with an isolation mechanism,. High reliability, with a mechanical lifespan of over 10000 cycles.
Split type button refers to the button body installed on the mechanism button column, with a dust-proof and error proof cover on the button operating part, installed on the cabinet panel to meet the functional requirements of dust-proof and error proof.
This series of products will be shipped after passing the full inspection and meet the common technical requirements of GB1984-2014 High Voltage Switchgear and Control Equipment Standards and GB/T 11022-2020 Common Technical Requirements of High Voltage AC Equipment and Control Equipment Standards

Instructions for use and operation

Energy storage operation:
Install and fix the mechanism cabinet, insert the mechanism specific handle into the operating shaft located at the lower right of the mechanism, and rotate the handle clockwise until a "click" sound is heard (at this time, the energy storage indicator shaft will slightly push the energy storage to the fully closed state) to store the energy in place. When operated electrically, the mechanism will automatically run energy storage after being powered on. Once the energy storage is in place, the motor circuit will be disconnected, the energy storage will remain, and wait for the energy release to close (the secondary circuit must be ensured to be accurate and error free during electric operation).
Closing operation:
Press the green button to instantly release the closing energy storage, and the mechanism will push the circuit breaker switch to complete the main circuit closing. During electric operation, the closing electromagnetic coil is powered on, and the energy storage is instantly released by the closing electromagnet. The mechanism pushes the circuit breaker switch to complete the main circuit closing, and at the same time, the opening spring is stored with energy (energy can continue to be stored at this time, but it cannot be closed again under the anti misoperation interlock)
Opening operation:
Press the red button to instantly release the disconnection energy storage, and the mechanism will push the circuit breaker switch to complete the main circuit disconnection. During electric operation, power is applied to the opening electromagnetic coil, and the energy storage is released instantly by the opening electromagnet. The mechanism pushes the circuit breaker switch to complete the main circuit opening.

Installation dimensions

FAQ
Q: What are the core advantages of this operating mechanism?
A:
The core advantages focus on four dimensions: reliability, safety, intelligence and adaptability, meeting the high-standard requirements of medium-voltage distribution networks: ① Reliable action: Adopt motor energy storage + spring operating structure, fast opening/closing speed (opening ≤60ms, closing ≤80ms), mechanical life ≥10000 times, ensuring fast current cutting in case of faults; ② Safety protection: Integrate mechanical and electrical interlock, over-torque protection, limit protection and anti-misoperation functions, eliminating hidden dangers such as live opening/closing and overstep tripping, ensuring the safety of personnel and equipment; ③ Intelligent adaptation: Support remote control, opening/closing status feedback, energy storage status monitoring and fault recording, can be linked with distribution network automation systems, adapting to unattended scenarios; ④ Environmental tolerance: Protection level ≥IP54, with strong anti-corrosion, moisture-proof and dust-proof performance, adapting to harsh environments such as coastal salt spray, high humidity and high pollution; ⑤ Compact structure: Adapt to the narrow installation space of gas cabinets, high transmission efficiency, precise matching with circuit breakers, and convenient installation.
Q: What is 12KV gas cabinet circuit breaker electric operating mechanism?
A:
It is a core electric drive component designed for circuit breakers of 12KV gas-insulated cabinets (including SF6 gas cabinets). Its core function is to drive the circuit breaker to realize fast opening and closing actions, which can not only connect and cut off normal load current, but also reliably cut off short-circuit fault current, realizing line fault protection and isolation. Relying on motor energy storage and electric drive mode, it adapts to the sealed and compact installation environment of gas cabinets, has remote control, status feedback and fault alarm functions, and is a key equipment for fault protection and intelligent control in 12KV medium-voltage distribution networks.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.