• Photovoltaic inverter grid-connected transformers
Photovoltaic inverter grid-connected transformers
discuss personally
Model
SGG/SD-60kVA
SGG/SD-80kVA
SGG/SD-100kVA
SGG/SD-25kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic inverter grid-connected transformers
Rated frequency 50/60Hz
Rated capacity 60KVA
Series SGG
Product Detail

Product Overview

An isolated transformer is a double-winding transformer that not only achieves voltage transformation in the power grid but also provides electrical safety isolation between input and output windings. This feature effectively prevents electric shock hazards when the human body comes into simultaneous contact with live components (or metal parts that may become charged due to insulation damage) and the ground. Additionally, it can isolate the third harmonics in the power grid, reduce heat generation during equipment operation, and extend the service life of insulating materials. It also functions to suppress and eliminate interferences such as noise, clutter, high voltage, and surges in the power grid, providing a pure power environment for equipment.

The dry-type photovoltaic transformers produced by our company are special transformers designed for photovoltaic grid-connected inverters. Adopting a foil winding process, the transformer core features a full-joint structure, and the core laminations are made of low-loss oriented silicon steel sheets, offering significant advantages of low loss, high efficiency, and low temperature rise. This series of transformers is suitable for circuits with an AC frequency of 50Hz/60Hz and a rated voltage below 690V, and can be custom-designed and manufactured according to specific user requirements.

Product features

  • Energy-saving and low-noise:High-quality cold-rolled silicon steel sheets are used for stacking; The special dipping process is used to effectively reduce the vibration and noise during operation; As well as the introduction of new processes and technologies such as the design of high-temperature resistant insulation materials, the transformer is more energy-saving and quieter. The coil has a ventilation groove to allow for smooth air flow, effectively reducing the coil temperature.

  • High reliability:The structure is reasonable, the efficiency is high, the waveform is not distorted, it is convenient and reliable to use, it can run for a long time, and the performance indicators fully meet the standard requirements of GB/6450 dry-type power transformer. It can isolate the power supply of the main power grid, anti-shock, anti-interference, and anti-lightning.

  • Eco-friendly features:It has heat resistance, moisture resistance, stability, chemical compatibility, low temperature resistance, radiation resistance and non-toxicity.

  • Versatility:From a single transformer to a multi-functional combined transformer with air cooling, protective housing, transformer and so on.

Model specifications:

Note:The dimensions and technical indicators of the above products can be customized according to customer requirements.

Application scenarios:

SGG/SD series photovoltaic inverter grid-connected transformer is a supporting product of solar photovoltaic, its rated input voltage is AC three-phase 270V, rated output voltage is AC three-phase 400V, rated working frequency is 50/60HZ, it will be the direct current in the solar energy through the photovoltaic inverter inverter out of the three-phase AC 270V voltage isolation and step-up into three-phase AC 400V voltage, in order to be integrated into the grid or directly supply the single-phase 220V and three-phase 380V AC power supply required by users.

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!