Low-Loss Three-Phase Photovoltaic Isolation Transformer

  • Low-Loss Three-Phase Photovoltaic Isolation Transformer

Key attributes

Brand ROCKWILL
Model NO. Low-Loss Three-Phase Photovoltaic Isolation Transformer
Rated frequency 50/60Hz
Rated capacity 1250kVA
Phases Three-phase
Series SGG

Product descriptions from the supplier

Description

Product Overview:

For many years, our company has specialized in manufacturing SD/SG(YSD) series single-phase and three-phase dry-type transformers dedicated to mechanical equipment, with capacities ranging from 1KVA to 3000KVA. Developed by referencing the latest similar products from Siemens, our SG series three-phase dry-type transformers not only provide voltage transformation in the power grid but also isolate third harmonics from the grid to equipment, reducing heat generation in machines and extending the service life of insulating materials. They are particularly suitable for imported equipment (380V input → 220V output, 380V input → any voltage output, 220V input → any voltage output) with specifications from 1KVA to 3000KVA.

Our SG and DG series dry-type isolation transformers are widely applicable to various power supply scenarios with AC 50-60HZ and input/output voltages not exceeding 3000V. All parameters, including input/output voltage levels, connection groups, tap positions, winding capacity distribution, secondary winding configurations, and whether a casing is required, are meticulously designed and manufactured according to user requirements.

Material Configuration Description of Transformer:

Transformers serve as the main components of various power supplies and electrical equipment. Isolation transformers consist of cylindrical windings and laminated cores, where the core is stacked with brand-new high-quality high-silicon silicon steel sheets using fully mitered joints. Our company employs advanced manufacturing processes, including imported Max high-speed automatic winding machines and a full set of vacuum pressure impregnation (VPI) equipment. The windings are formed using the skeletonless full-series winding method, and the transformers undergo vacuum impregnation to achieve insulation classes of F (155℃) or H (180℃).The input and output voltages of the transformer can be designed according to customer requirements, available in various specifications such as single-phase, three-phase, or multiple-way input/output configurations.

  •  Core:Made of brand-new high-quality high-silicon silicon steel sheets, mainly with materials of 0.35mm thick H18, H14, H12, and Z11 high-quality silicon steel sheets. We select the most suitable material based on customer requirements and usage conditions to optimize the transformer's performance design. (Conventional material: brand-new high-quality silicon steel sheets).

  • Wire:Using PEW, UEW, EIW, SEIW, FEAI enameled wires and glass fiber-covered wires, with temperature resistance grades of F (155℃), H (180℃), HC (200℃), and C (220℃). (Conventional temperature resistance grade: H grade, 180℃).

  • Insulating Materials:Adopting high-temperature resistant insulating paper as the insulating material, which has multiple properties of high-temperature insulation, flame retardancy, and moisture resistance.

  •  Insulating Material Terminal Blocks

  • For low-power applications: Using terminal blocks, which feature a beautiful appearance and excellent voltage resistance, temperature resistance, and flame retardant properties.

  • For high-power applications: Using high-quality copper busbars.

  •  Iron Feet:Mainly made of CNC bent cold-rolled steel plates, with environmentally friendly electroplating options such as multicolor plating (golden yellow), blue zinc (silver white), white zinc (ivory white), and surface anodizing (black).

Technical data:

Low-Loss Three-Phase Photovoltaic Isolation Transformer.png

Low-Loss Three-Phase Photovoltaic Isolation Transformer.png

Product Operating Conditions:

  • Applicable altitude: ≤ 5000m

  • Ambient temperature: -15℃~+45℃

  • Relative humidity: ≤ 90%

  • The installation site shall be free of gases, vapors, chemical deposits, dirt, conductive dust that seriously affect the insulation strength of the transformer, and free of other explosive, flammable, and corrosive substances.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.