•  Photovoltaic Auxiliary Energy Storage Transformer
Photovoltaic Auxiliary Energy Storage Transformer
discuss personally
Model
SGG-200kVA
Basic info
Brand ROCKWILL
Model NO. Photovoltaic Auxiliary Energy Storage Transformer
Rated frequency 50/60Hz
Rated capacity 200kVA
Series SGG
Product Detail

Product Overview:

The grid-connected energy storage auxiliary isolation transformer for photovoltaic power generation is generally used for solar inversion, with common voltages including 800V to 400V, 380V, 690V to 400V, 540V to 400V, etc. (customizable as required); due to the low photoelectric efficiency of photovoltaic silicon panels, the transformer is specially required to have high efficiency. The photovoltaic isolation transformer is equipped with a microcomputer intelligent time controller to set daytime operation and nighttime stop for reducing no-load power loss, a temperature controller to real-timely monitor the operating temperature of the transformer, control the start and stop of the cooling fan, and automatically stop and disconnect the transformer when the operating temperature is too high to reach the set critical temperature for protecting the safety of the transformer body, a self-reset overvoltage and undervoltage protector to prevent islanding operation, a surge protector to effectively prevent lightning damage to equipment and improve the safety factor of the power generation system, and a knife switch on the grid-connected side to facilitate effective operation and maintenance of the equipment.
Key Features:
  • Smart Controls: Microcomputer time controller reduces nighttime no-load losses.
  • Safety Protections:
  • Temperature monitor with auto-shutdown at critical thresholds.
  • Over/under-voltage self-reset protector prevents islanding.
  • Surge arrester for lightning protection.
  • Grid-side knife switch for maintenance.
  • Flexible Configurations: Available in single/multi-unit combinations (1:2, 1:3, etc.) for scalable PV systems.

Technical data:

Operating Conditions

  • Ambient Temperature: -15 to +50°C
  • Relative Humidity: 20 to 90% RH
  • Atmospheric Pressure: 860 to 1060 hPa
  • Storage/Transport Temperature: -20 to +55°C
  • Rated Capacity: 5-300KVA
  • Input Voltage: 800V
  • Input Current: As per actual capacity
  • Output Voltage: 400V
  • Output Current: As per actual capacity
  • Connection: Dyn11 (△/Y), Yny0 (Y/Y)
  • Efficiency: ≥96%
  • Frequency: 50Hz/60Hz
  • Insulation Impedance: ≤500MΩ at 25mA
  • Inductive Withstand Voltage: 125Hz/800V/60s
  • Insulation Class: Class H (155°C temperature resistance)
  • Noise Level: ≤30dB
  • Temperature Rise: ≤115K allowable
  • Impedance Voltage Drop: ≤4%
  • Cooling Structure: Forced air cooling with temperature controller (fan starts automatically at set temperature per customer requirements)
  • Protection Class: IP54
  • Anti-Interference Method: Copper foil isolation, shielded grounding
  • Waveform Distortion: No additional distortion
  • Electrical Strength: 3000V AC power frequency sine voltage for 1min without breakdown/flashover
  • Insulation Resistance (input/output to ground): Test voltage ≥1000VDC, insulation resistance >50MΩ
  • Overload Capacity: 2x rated current for 1min

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!