Outdoor Medium Voltage Air Load Break Switch-18-33kV

  • Outdoor Medium Voltage Air Load Break Switch-18-33kV
  • Outdoor Medium Voltage Air Load Break Switch-18-33kV

Key attributes

Brand ROCKWILL
Model NO. Outdoor Medium Voltage Air Load Break Switch-18-33kV
Rated voltage 40.5kV
Rated frequency 50Hz
Series FKW18

Product descriptions from the supplier

Description

Product Introduction

High voltage load air load break switch is a new type of load switch designed and manufactured by integrating domestic production experience of similar switches and foreign advanced technology. The outdoor load break switch is composed of isolation knife, arc extinguishing chamber and operating mechanism. Adopting the principle of gas gen eration and arc extinguishing, it has the advantages of simple structure, low maintenance workload, strong arc extinguishing ability, high fracture insulation level and high reliability, reaching the advanced level of similar products at home and abroad. FKW18 series outdoor AC high voltage load switch is suitable for outdoor three-phase AC power distribution system with rated voltage of 140.5KV and rated frequency of 50Hz. It can open and close distribution lines with load, and can also be used as open and close no-load lines. The use of no -load transformer, in the opening position, can meet the safety distance requirements specified for the disconnecting switch.

Working Environment

  • Altitude: no more than 3000m;
  • Ambient air temperature: the upper limit is 40°C, the lower limit is -25°C, and the daily temperature difference does not exceed 32K;
  • The wind pressure does not exceed 700Pa (equivalent to wind speed 34m/s);
  • Air pollution degree: Allowed to be level IV;
  • The earthquake intensity does not exceed 8 degrees;
  • The thickness of icing shall not exceed 10mm

Main Technical Parameters

 No ltem Unit Dala
1 Rated voltage kV 40.5
2 Rated current A 800
3 Raled frequency Hz 50
4 Rated peak withstand current kA 50
5  Rated short-time withstand current  kA 20
6 Rated short-time withstand current duration S 4
7 Rated aclive load breaking current A 800
8 Rated closed-loop breaking current A 800
9 Rated cable charging current A 10
10 Rated active load breaking current A 31.5
11 No-load transformer current opening rated capacity kVA 1250
12 Rated short circuit switching current kA 50
13 Main circuit resistance μΩ ≤95
14 1 min Power frequency
withstand voltage (valid value
Dry Interphase,phase to earth kV 95
isolating fracture 15
Wet Interphase,phase to earth kV 85
15 Lightning impulse withstand voltage (peak) Interphase,phase to earth kV 185
isolating fracture 215
16 Mechanical life Times 2000
17 Different Periods of Three-phase Separation and Closing ms ≤15
18 Motor voltage,power  V  W 220 ≤200
19 Deflection of blade rigid position mm ≤5
20 Main contact blade pressure N 420±42
21 Contact blade opening distance mm ≥360
22 Rated operating torque  N·m ≤300
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.