Easy Operation Vacuum Load Switch

  • Easy Operation Vacuum Load Switch

Key attributes

Brand ROCKWILL
Model NO. Easy Operation Vacuum Load Switch
Rated voltage 25kV
Rated frequency 50Hz
Series FZN

Product descriptions from the supplier

Description

Summary
FZN25, FZRN25 type vacuum load switch and composite apparatus, suitable for three- phase AC 50Hz ring network Or terminal power supply and industrial electrical equipment, for load control and short circuit protect ion use, load switch open and close the closed loop current, no-load transformer and cable charging current, composite apparatus can break any current till rated short circuit current. Adopt the straight move Or isolating fracture and vacuum interrupter linkage . With function of manual and electric operation.
FZN25, FZRN25 special transmission structure design, arc extinguish chamber only withstand voltage in the moment of closing and breaking, small size, Light weight.
FZN25, FZRN25 can realize isolation fracture and arc extinguish chamber fracture disposable operating.
FZN25, FZRN25 has a grounding switch mutual linkage grounding valve between the static contact and mova conductive cylinder, ensures safety and convenient maintenance.
Ambient condition

  • The ambient temperature: -25°C-+40°C, alpine region,-40°C;
  • The altitude:≤1000M;
  • Relative humidity: daily average value is not greater than 95%, monthly average is not 9reater than 90%;
  • Earthquake intensity:≤ 8 degree;
  • The surrounding air is not corrosive and flammable gas, steam and other significant pollution;
  • Contamination grade: II class;

Specifications

Item Units Parameters
FZN25-12D/T630-20 FZRN25-12D/T125-31.5
Rated voltage kA 12
Rated frequency Hz 50
Rated Current A 630 125
Rated insulation level 1min  frequency voltage kV lnterrupter Fracture30.on the ground,
white 42 .solation Fracture48
Lightning impulse withstand voltage kV On the ground, white 75 solation Fracture85
Rated dynamic stability current (peak) kA 50
4Sthe rmal current kA 20
Rated active load breaking current A 630 125
Rated closed-Loop break1ng current A 630 125
Rated cable charging breaking current A 10 10
Breaking load transformer kV 1250 1250
Rated short-c1rcuit breaking current kA 31.5
Rated transfercu rrent,rated current transfer A 2000
Fuse Model   SDLAJ-12SFLAJ-12
Impact energy output J 2-5
Rated short circuit making current kA 50
Ground switch rated Dynamic current kA 50
Grounding switch 2S thermal current kA 20
Seconda ry Circu it Rated voltage V AC/CD220;110
Mechanical life Times 1000
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.