• 6~30KV XLPE Insulated Power Cable
  • 6~30KV XLPE Insulated Power Cable
6~30KV XLPE Insulated Power Cable
discuss personally
Model
XLPE-30
XLPE-20
XLPE-15
XLPE-10
XLPE-6/10
XLPE-6/6
XLPE-3/6
Basic info
Brand Wone
Model NO. Medium voltage XLPE insulated power cable from 6kV up to 30kV
Rated voltage 3.6/6kV
Core Single core
Series XLPE
Product Detail

Rated voltage: 3.6/6kV -single core 

(ZR)YJV: CU/XLPE/CTS/PVC; (ZR)YJLV:AL/XLPE/CTS/PVC (ZR)YJY:CU/XLPE/CTS/PE;(ZR)YJLY:AL/XLPE/CTS/PE

Parameters

image.png

Rated voltage: 6/6kV, 6/10kV -single core

 (ZR)YJV: CU/XLPE/CTS/PVC; (ZR)YJLV:AL/XLPE/CTS/PVC (ZR)YJY:CU/XLPE/CTS/PE;(ZR)YJLY:AL/XLPE/CTS/PE

image.png

Rated voltage: 8.7/10kV, 8.7/15kV -single core

 (ZR)YJV: CU/XLPE/CTS/PVC; (ZR)YJLV:AL/XLPE/CTS/PVC (ZR)YJY:CU/XLPE/CTS/PE;(ZR)YJLY:AL/XLPE/CTS/PE

image.png

Rated voltage: 12/20kV -single core 

(ZR)YJV: CU/XLPE/CTS/PVC; (ZR)YJLV:AL/XLPE/CTS/PVC (ZR)YJY:CU/XLPE/CTS/PE;(ZR)YJLY:AL/XLPE/CTS/PE

image.png

Rated voltage: 18/30kV -single core 

(ZR)YJV: CU/XLPE/CTS/PVC; (ZR)YJLV:AL/XLPE/CTS/PVC (ZR)YJY:CU/XLPE/CTS/PE;(ZR)YJLY:AL/XLPE/CTS/PE

image.png


Cable code designation

image.png

IEC Standards

image.png

Q: What is an XLPE cable?

A: XLPE cable is a cross-linked polyethylene insulated cable. It uses crosslinked polyethylene as an insulating material to wrap the conductor. 

Q: What are the advantages of XLPE cables? 

A: First of all, XLPE cable has excellent electrical performance, high insulation resistance and small dielectric constant, which can effectively reduce power loss. Secondly, it has good heat resistance and can operate stably at higher temperatures for a long time, which improves the current carrying capacity of the cable. Moreover, XLPE cable has good mechanical properties, strong tensile strength and wear resistance, and is not easy to be damaged during laying and use. Moreover, it has good chemical stability, strong corrosion resistance and ADAPTS to a variety of environments. 

Q: What are the main applications of XLPE cables? 

A: It is widely used in the urban power grid transformation, because its stable performance can meet the high demand for power supply in the city. It is also commonly used in the power supply system of large buildings and industrial plants, and the transmission lines from substations to distribution rooms are also used.

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!