• LB Oil immersed hair pin current transformer
  • LB Oil immersed hair pin current transformer
LB Oil immersed hair pin current transformer
discuss personally
Model
LB6-40.5
Basic info
Brand Wone
Model NO. LB Oil immersed hair pin current transformer
Rated voltage 40.5kV
Series LB
Product Detail

Product introduction:
LB series current transformers are oil impregnated paper insulated, vertical structure to meet the IEC/IEEE stan dard. The series connected transformer in the line has the functions of electric energy measurement, metering, relay protection and transient protection.
Product features:
●LB series current transformers are of oil immersed fully sealed insulation structure. The primary winding is U type. The body is fixed at the bottom of the box. The main insulation is capacitive oil paper insulation, which is wrapped around the primary winding with high-voltage cable paper. Several capacitance screens are set between them. The inner screen is connected to the high potential, and the outer screen can be grounded.
●The upper part of the oil tank is equipped with a porcelain bushing. The primary outlet terminal is on the top of the porcelain bushing. The series and parallel connection are external exchange devices, that is, they can be exchanged outside the porcelain bushing.
●The stainless steel expander is used as the oil compensation device to ensure the oil quality. The oil level indica tion of the product is indicated by the eye-catching displacement indication of the upper window of the expander.
●The product can be equipped with 4-6 secondary windings. The secondary measurement windings made of microcrystalline alloys with high magnetic conductivity can ensure the measurement accuracy to reach class 0.2 or 0.2S × The secondary winding of 600A and above current transformer measurement level has taps to achieve two current ratios.
●The secondary terminal box is cast with aluminum alloy as a whole, with a dust-proof, waterproof and breathable sealing structure
●The connection between product parts adopts argon arc welding, and the whole assembly is filled with high-pressure nitrogen for leak detection, which fundamentally solves the problem of oil leakage of oil immersed products.
●The shell, base and junction box are all made of aluminum alloy. The expander and nameplate are made of stainless steel. All exposed parts will never rust.
●The product is maintenance free.
LB Oil immersed hair pin current transformer-2.png

LB Oil immersed hair pin current transformer-3.png

Remark: Approximate dimensions and weights for special requirements, please consult us.

Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
Felix Spark
07/18/2025
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Analysis of the Principle of Second - harmonic Restraint for Overcurrent Protection of Distribution Automation Switches
Substance of Second - harmonic Restraint in Overcurrent ProtectionThe substance of second - harmonic restraint in overcurrent protection is to use the second - harmonic component to judge whether the current is a fault current or an excitation inrush current. When the percentage of the second - harmonic component to the fundamental - wave component is greater than a certain value, it is judged to be caused by the excitation inrush current, and the overcurrent protection is blocked.Therefore, the
Leon
07/18/2025
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!