• JSZV18-24RJ Voltage Transformer
JSZV18-24RJ Voltage Transformer
discuss personally
Model
JSZV18-24RJ-22kV
JSZV18-24RJ-20kV
Basic info
Brand Wone Store
Model NO. JSZV18-24RJ Voltage Transformer
Rated frequency 50/60Hz
Primary voltage 22kV
Secondary voltage 100/220V
Series JSZV
Product Detail

Product Overview

JSZV18-24RJ voltage transformer, is fully enclosed casting insulation structure, the primary winding, secondary winding and the annular core all coating in the epoxy resin casting, The product adds elbow type plug part, improving the filth and moisture resistance, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest   voltage for equipment 24 kV.

Key Features   

  • Wide Voltage Range Adaptability:The JSZV18-24RJ voltage transformer can adapt to significant voltage fluctuations based on the rated 24kV. It not only ensures normal operating voltage monitoring but also stably outputs accurate signals during transient voltage fluctuations or system voltage regulation, safeguarding the normal operation of measurement and protection systems.

  • Fast Response Characteristics:With high-speed voltage signal response capability, it captures voltage changes in an extremely short time and converts them into secondary-side signals. When sudden voltage surges or drops occur in the power system, it provides timely signals for relay protection devices to quickly cut off faulty circuits.

  • Low Hysteresis Loss:Using special magnetic materials and optimized design, it achieves extremely low hysteresis loss, reducing energy loss during conversion, improving transformer efficiency, minimizing long-term operational heating, and enhancing equipment stability and service life.

Technical Parameters

  • Rated primary voltage:20kV or 22kV

  • Rated secondary voltage:100V,100/100V,100/220V

  • Rated voltage of residual voltage windings:100/ 3V 、110/ 3V、 115/ 3V、 120/ 3V

  • Burden power factor: cosΦ=0.8(lagging)

  • Standards: IEC60044-2.2003 or IEC61869-1&3

Other technical parameters pls see as follow:

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l