HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid

  • HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid

Key attributes

Brand Switchgear parts
Model NO. HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series HXGH17

Product descriptions from the supplier

Description

The HXGN17-12 AC Metal-enclosed Ring Main Unit Switchgear (hereinafter referred to as "ring main unit") is a new product designed and developed by from oversea advanced latest techniques. The technical indicators of the product reaches standard of IEC62271-200 and GB3906. The product is characterized by small volume,light weight,operation flexibility,maintenance convenience, and quality stability & reliability, and it comes out with perfect interlock protection functions and IP3X protecton grade, so it is an ideal product for mains grid reconstruction. The product is mainly applicable to three-phase AC network for receiving and distributing energy.

Mainly applicable in urban power grid construction and renovation project. industrial and mining enterprises.high-rise buildings and communal facilities .For power distribution .controlling and protection on electric equipment as the loop power supply unit or termina equipment. It also can be installed in preloaded substation.

Working Environment

1.Altitude: Not exceed 2500m above sea level

2.Ambient temperature:-25℃ ~ +45℃, the highest temperature is not exceed25℃

3.Ambient humidity: Daily average RH ≤ 95%; Monthly average RH ≤ 90%

4.Earthquake intensity: ≤ 8°

5.No flammable, explosive, no serious pollution, No chemical corrosion and severe vibration.

Technical Parameters

No.

Item

 

Unit

Data

       

FN12-10

FZN25-12

1

Rated voltage

 

kV

12

12

2

Rated current

load break switchgear

A

630

630

Combined switchgear

A

125

125

3

Rated frequency

 

Hz

50

50

4

Rated short-circuit breaking current

 

kA

31.5

31.5

 

Rated short-time withstand current

 

kA

20

20

 

Rated active on-load breaking current

 

A

630

630

5

Rated peak withstand current

 

kA

50

50

6

Rated power frequency voltage withstands inter-phase, to earth and to the open contact

 

kV

42

48

7

Thundering withstands voltage inter-phase, to earth and to the open the contact

 

kV

75

85

8

Mechanical life

 

times

10000

10000

9

Rated take-over current

 

A

3150

3150

10

Protection level

   

IP2X

IP2X

11

Operating mode

   

Manual or automatic

Manual or automatic

12

Control circuit rated voltage

 

V

DC: 110, AC:220

DC: 110, AC:220

FAQ
Q: Can HXGN17-12 630A Ring Main Unit be customized for special requirements?
A:

Customization options include: ① Adjusting IP protection level (up to IP54 for harsh environments); ② Adding electric/manual operation mode switching; ③ Matching different accessories for box-type substation integration. Contact our technical team with your specific voltage, current, or environmental needs for tailored solutions.

Q: What are the key differences between HXGN17-12 and HXGN15-12 Ring Main Units?
A:

Both are 12kV switchgears, but HXGN17-12 adopts a single-busbar structure with integrated "five-prevention" interlock, more suitable for frequent operation and terminal power supply. HXGN15-12 uses SF6 composite switches with air insulation, focusing on distribution automation expandability. Choose HXGN17-12 for scenarios requiring compact structure and stable interlocking performance.

Q: What is the main application scenario of HXGN17-12 11KV 630A Ring Main Unit?
A:

 It is a fixed metal-enclosed switchgear designed for 3-12kV AC 50/60Hz power systems with rated current ≤630A. Ideal for industrial and mining enterprises, box-type substations, urban power grids, and high-rise building power distribution, it excels in frequent operation scenarios with reliable power control and protection functions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.