• 484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)
484MVA/500kV GSU Generator Step-Up Transformer Nuclear Power Plant(Transformer for generation)
discuss personally
Model
GSU-484MVA/500kV
Basic info
Brand ROCKWILL
Model NO. GSU transformer for nuclear power plant
Rated frequency 50/60Hz
Series GSU
Product Detail

Description

The GSU (Generator Step-Up) Transformer plays a critical role in nuclear power plants as a core electrical device connecting nuclear generators to the transmission grid. Within the plant, nuclear reactors produce massive thermal energy, which is converted into high-temperature, high-pressure steam via steam generators to drive turbine generators and generate electricity. At this stage, the generator outputs medium-low voltage alternating current (typically 10–20kV). The primary function of the GSU transformer is to significantly boost this voltage to levels such as 110kV, 220kV, or higher, meeting the demands of long-distance, large-capacity power transmission, reducing energy loss during transmission, and enabling efficient integration of nuclear power into the grid. Its operational status directly impacts the stability and reliability of nuclear power output, as well as the safe and stable operation of the entire power system, making it a key hub for ensuring continuous and stable power supply from nuclear plants.

  • 1-Ph 484MVA/500kV

Features

  • Ultra-High Reliability and Stability: Nuclear power plants have extremely stringent operational requirements. GSU transformers use top-quality high-permeability silicon steel sheets for cores and high-purity oxygen-free copper for windings, combined with advanced manufacturing processes and insulation technologies. This ensures reliable and stable operation under long-term high loads and continuous service, minimizing failure risks and reducing disruptions to nuclear power generation. They are also equipped with redundant protection and monitoring systems, such as multiple relay protection devices that real-time monitor current, voltage, and temperature. These systems act quickly to cut off circuits in case of abnormalities, preventing fault escalation. Additionally, smart sensors continuously track equipment performance, providing data support for preventive maintenance to keep the device in optimal condition.

  • Strong Short-Circuit Resistance: The internal power grid of nuclear plants is complex, and short-circuit faults may occur under abnormal conditions, generating powerful short-circuit currents and electromagnetic forces. GSU transformers feature specially wound windings to enhance mechanical strength and stability between windings, enabling them to effectively withstand the impact of strong electromagnetic forces during short circuits. This maintains structural integrity, ensures transformer safety, and avoids severe consequences such as equipment damage or even nuclear plant shutdowns caused by short circuits.

  • Adaptability to Harsh Environments: Nuclear power plants have complex internal environments with factors like radiation, high temperatures, high humidity, and chemical corrosion. GSU transformers are designed with enclosures featuring excellent shielding performance to effectively block radiation and protect internal electrical components. They use high-temperature-resistant, moisture-resistant, and corrosion-resistant insulation materials and protective coatings, ensuring stable insulation performance in high-temperature and high-humidity environments. This prevents issues like insulation aging or short circuits caused by environmental factors, guaranteeing long-term normal operation in harsh nuclear plant conditions.

  • Large Capacity and High-Voltage Compatibility: As nuclear power plant generation capacity continues to increase, demands for GSU transformer capacity and voltage levels have risen. These transformers typically offer capacities of several hundred MVA or higher, with voltage levels that match grid connection requirements—stepping up from tens of kV to 110kV, 220kV, or higher. This enables efficient large-scale transmission of nuclear power, meeting society’s massive electricity needs.

  • Low Loss and Energy Efficiency: Amid growing emphasis on energy utilization and environmental protection, GSU transformers for nuclear power plants focus on minimizing losses. Through optimized core structures and improved winding designs, they reduce core hysteresis losses and winding resistance losses, enhancing energy conversion efficiency. This lowers power generation costs, reduces unnecessary energy waste and carbon emissions, and aligns with green development concepts.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!