• 840MVA/500kV GSU Generator Step-Up Transformer Hydro Power Plant
840MVA/500kV GSU Generator Step-Up Transformer Hydro Power Plant
discuss personally
Model
GSU-110/300MVA
Basic info
Brand ROCKWILL
Model NO. GSU transformer for Hydro P/P
Rated frequency 50/60Hz
Series GSU
Product Detail

Description of GSU for Hydro P/P

GSU (Generator Step-Up) Transformer for Hydroelectric Power Plants (Hydro P/P) is a critical equipment connecting hydropower generators to the transmission grid. Its core function is to boost the low-voltage electricity (typically 6.3kV–13.8kV) generated by hydro turbines—driven by water flow—into high-voltage power (110kV–500kV or higher). This enables efficient long-distance transmission of hydropower, minimizes line losses, and ensures stable integration with the main grid. As a key link in hydropower systems, it directly supports the reliable delivery of clean, renewable energy from dams or run-of-river plants to end-users.

Features of GSU for Hydro P/P

  • Adaptability to Variable Loads: Optimized to handle fluctuating power output caused by water flow variations (e.g., seasonal changes, dam release adjustments), with strong overload capacity to accommodate sudden surges in generation.

  • High Insulation & Moisture Resistance: Designed for hydroelectric environments (often near water or in humid conditions), using moisture-resistant insulation materials and sealed tank structures to prevent water ingress and insulation degradation.

  • Compact Design for Space Constraints: Suitable for installation in confined areas (e.g., powerhouses within dams), with a space-saving structure that fits alongside turbines and other hydropower equipment without compromising performance.

  • Low Noise Operation: Adopts low-loss core materials and vibration-damping designs to reduce operational noise, aligning with environmental regulations—critical for hydropower plants in ecologically sensitive or residential areas.

  • Grid Compatibility: Equipped with voltage regulation and harmonic filtering features to meet grid codes, ensuring stable power quality (e.g., minimal voltage fluctuations) when integrating hydropower into the grid.

  • Long-Term Durability: Constructed with corrosion-resistant components (e.g., stainless steel hardware) to withstand damp, possibly saline environments (for coastal hydro plants), ensuring a design life of 30+ years with minimal maintenance.

 

 

 

 

 

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Issues and Causes in Smart Meter Testing
Analysis of Issues and Causes in Smart Meter Testing
1. Issues and Cause Analysis in Smart Electricity Meter TestingDuring the verification of smart electricity meters, inspections must be conducted on the meter’s appearance, as well as the clarity and integrity of nameplate markings. Additionally, careful checks are required for physical damage and whether the display can show digits completely. A power-on inspection is also necessary. If error codes appear on the display after power-up, faults should be identified and addressed according to the
Oliver Watts
09/01/2025
Analysis of Common Operational Fault Causes in Smart Electricity Meters
Analysis of Common Operational Fault Causes in Smart Electricity Meters
With the continuous development of smart grids, smart electricity meters are being increasingly widely applied, and various types of operational faults in smart meters are frequently encountered in energy measurement work. This paper analyzes the causes of smart meter failures and proposes corresponding solutions, using several actual operational fault cases as examples.1. Black ScreenA black screen refers to a powered meter with no display, which is the most commonly occurring fault in field-op
Felix Spark
09/01/2025
What tests are required for a qualified smart electricity meter?
What tests are required for a qualified smart electricity meter?
In today's world, not wearing a watch is no longer unusual, but not having an electricity meter is a serious issue. As a measuring instrument vital to people's daily lives, the electricity meter is an essential tool for power consumption measurement and billing in every household. According to current national strategic requirements for smart grid development, smart electricity meters have been widely applied and promoted, bringing entirely new and extensive market opportunities to the metering
Oliver Watts
09/01/2025
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
Discussion on Fault Diagnosis and Handling Technologies for Smart Meters in Electricity Inspections
1 Analysis of Smart Meter Faults and Their Impact on the Power Grid1.1 Introduction to Smart Meter Functions and Their Critical Role in Modern Power GridsSmart meters exchange data in real time with power companies through two-way communication, enabling functions such as remote meter reading and dynamic tariff adjustment. This capability allows users to adjust their consumption based on real-time pricing, achieving energy savings and cost reduction. Meanwhile, smart meters support grid automati
Felix Spark
09/01/2025
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Analysis of the Integrated Application of Smart Meters and Meter Reading, Verification, and Billing Information Systems
Meter reading, verification, and billing are critical operations for power companies, and their efficiency directly impacts the company's sustainable development. In recent years, with the widespread adoption of intelligent technologies, smart meters have been promoted and applied in power companies, driving transformation in meter reading and billing operations. The integrated application of smart meters and meter reading, verification, and billing information systems has become a key developme
Echo
09/01/2025
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!