Grounding flange

  • Grounding flange

Key attributes

Brand Switchgear parts
Model NO. Grounding flange
Rated voltage 126kV
Series RN

Product descriptions from the supplier

Description

Grounding flange is a component used in the fields of power equipment, electrical systems, etc. to achieve grounding connection function. Combining with the grounding flange in this picture, the following will introduce it to you:
Basic structure and appearance
These grounding flanges have a disc-shaped appearance, with a white body and some holes distributed on top. These holes are usually used for bolt installation and fixation to connect the grounding flange to other equipment components. At the same time, it also comes with metal connectors (such as copper components), which are used for electrical connection and grounding function.
working principle
The grounding flange is connected to the grounding wire through a metal connector. When the equipment experiences leakage or abnormal high voltage, the current can be introduced into the ground through the grounding flange, thereby ensuring the safety of the equipment and personnel. For example, in high-voltage electrical equipment, once the insulation is damaged, the fault current can quickly dissipate to the ground through the grounding flange, avoiding electric shock to personnel and further damage to the equipment.
Application scenarios
Power system: In GIS (gas insulated metal enclosed switchgear), grounding flanges are used to ground the equipment casing and ensure safe operation; Grounding flanges are also used at cable terminals, cable joints, and other locations to ensure the electrical safety of the cable system.
Industrial equipment: Some large industrial electrical equipment, such as large motors, transformers, etc., achieve reliable grounding of the equipment casing through grounding flanges to prevent equipment leakage and safety accidents.
Performance Requirements
Electrical performance: It has good conductivity to ensure that fault current can be quickly introduced into the ground and reduce grounding resistance. Generally, it is required that the grounding resistance be within the specified range, such as not exceeding a few ohms.
Mechanical performance: It has certain strength and corrosion resistance, and can withstand mechanical stress and environmental erosion during equipment operation. Because the grounding flange needs to be installed on the equipment for a long time, it needs to adapt to different environmental conditions, such as humidity, acidity, and alkalinity.

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.