GPS8-10 Wifi Voltage and Current Protector

  • GPS8-10 Wifi Voltage and Current Protector
  • GPS8-10 Wifi Voltage and Current Protector
  • GPS8-10 Wifi Voltage and Current Protector
  • GPS8-10 Wifi Voltage and Current Protector

Key attributes

Brand Switchgear parts
Model NO. GPS8-10 Wifi Voltage and Current Protector
Rated voltage AC220V
Rated normal current 32A
Rated frequency 45Hz-65Hz
Series GPS8-10

Product descriptions from the supplier

Description

The GPS8-10 voltage/current protector is a high-performance device that integrates multifunctional power protection and intelligent monitoring, designed specifically for household electrical safety and energy management needs. The measurement technology and reliable protection mechanism adopted by the product not only ensure electrical safety, but also provide users with real-time power parameter monitoring function, making it an intelligent steward of the household power system.

General
Applications
 -Overvoltage, undervoltage, overcurrent and leakage protection for household equipment, while displaying frequency, power factor, power, and electricity co

Function Features
 -Overvoltage, undervoltage, overcurrent, and leakage protection.
 -Special metering chips are used to detect voltage, current, electricity
 consumption and power.
 -Double bus wiring design stronger ability.
 -Over / under voltage value and over-current value can be set.
 -Self reset after fault.
 -Large color screen display.
 -DIN rail mounting. 

Model

GPS8-10 Wifi Voltage and Current Protector

Function

Over voltage, under voltage and over current

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65Hz

Operation voltage range

80V~400V(L-N)

Rated operational current

32A,40A,50A,63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Over current operation value

1~32A,40A,50A,63A,80A

Over current action delay

2s~600s

Leakage current value

OFF,10mA~400mA

Leakage reclosing count

OFF,1~20,ON

Power-up delay

2s~600s

Reset time

2s~900s

Measurement error

≤1%

Electrical life

1x104

Mechanical life

1x106

Operating temperature

-20℃ ~ +60℃

Storage temperature

-35℃ ~ +75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

IP40 for front panel/IP20 terminals

Operating position

any

Overvoltage cathegory

III.

Pollution degree

2

Dimensions

82*54*68mm

Weight

205g

Documentation Resource Library
Restricted
GPS8-10 Wifi Voltage and Current Protector
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the core functions and advantages of the GPS8-10?
A:

The core functions and advantages focus on four dimensions: intelligent control, comprehensive protection, precise monitoring, and convenient adaptation:

·WiFi intelligent interconnection: Supports mobile APP remote control (on/off, parameter setting), real-time data monitoring and remote fault alarm, adapting to smart home scenarios, and ensuring electrical safety even when unattended.

·Three-in-one precise protection: Integrates overvoltage, undervoltage and overcurrent protection with customizable protection thresholds. The dual-bus wiring design improves power supply stability, quickly cutting off the fault circuit to avoid equipment burnout.

·Full-parameter precise monitoring: Real-time monitoring of voltage, current, power and energy consumption with a measurement error ≤1%. The digital display and APP show synchronized data, making energy management clear at a glance.

·Convenient installation and humanized design: 35mm standard DIN rail plug-and-play, compact size (refer to the same series 82×36×68mm) and light weight; automatic reset after fault eliminates the need for manual intervention. With an operating temperature range of -20℃~+60℃ and a protection level of IP40 (front panel)/IP20 (terminals), it adapts to various usage environments.

Q: What is the GPS8-10 WiFi Voltage and Current Protector?
A:

The GPS8-10 is a multi-functional power distribution device integrating WiFi intelligent control and three-in-one protection (overvoltage, undervoltage, overcurrent), specially designed for residential and small commercial scenarios. Compatible with AC 220V rated voltage and 45~65Hz frequency, it covers a working voltage range of 80V~400V. Adopting 1-MODULE standard DIN rail installation, it is equipped with a dedicated metering chip (measurement error ≤1%), supporting real-time monitoring of voltage, current, power and energy consumption. It can realize remote control, parameter setting and fault alarm through mobile APP, featuring dual-bus wiring design and automatic reset function (adjustable reset time), equipped with digital display and LED fault indicators, fully protecting electrical equipment and electrical safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.