Key attributes

Brand Switchgear parts
Model NO. GPS8-06 Voltage / Current Protector
Rated voltage AC220V
Rated normal current 32A
Rated frequency 45Hz-65Hz
Series GPS8-06

Product descriptions from the supplier

Description

GPS8-06 is an intelligent voltage/current protector with digital display function, which can monitor line voltage, current and power status in real time, and achieve automatic power-off protection by setting protection thresholds. Integrated WiFi communication and energy metering functions, supporting remote monitoring and data query through mobile apps, making it an ideal power management device for homes and small commercial spaces

GPS8-06 Digital Voltage/Current Protector Product Features:
1. Visual monitoring
The high-definition digital screen displays real-time voltage and current values, and the operating status is clear at a glance;
The LED indicator light provides intuitive feedback on the type of fault (such as overvoltage/undervoltage/overcurrent) and quickly locates the problem.
2. Intelligent control
Support custom overvoltage, undervoltage, and overcurrent protection thresholds, flexibly matching different device requirements;
Built in WiFi module, can remotely start and stop devices, query real-time data and historical records through a dedicated APP.
3. High precision electric energy metering
Real time monitoring of active power and cumulative electricity consumption (kWh) to assist users in analyzing energy consumption patterns;
Measurement error ≤1%, provide reliable data support.
4. Stable and reliable hardware design
The dual manifold structure enhances conductivity stability and supports larger current loads;
35mm standard guide rail installation, compatible with mainstream distribution boxes, easy to construct.

GPS8-06


Function

Over voltage,under voltage and over current

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65Hz

Operation voltage range

80V~400V(L-N)

Rated operational current

32A,40A,50A,63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Over current operation value

1~32A,40A,50A,63A,80A

Over current action delay

2s~600s

Power-up delay

2s~600s

Reset time

2s~900s

Measurementerror

≤1%

Electrical life(AC1)

1x10⁴

Mechanical life

1x106

Operating temperature

-20℃~+60℃

Storage temperature

-35℃~+75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

P40 for front panel/IP20 terminals

Operating position

any

Overvoltage cathegory

Ⅲ.

Pollution degree

2

Dimensions

82x36x68mm

Weight

135g

Documentation Resource Library
Restricted
GPS8-06 Voltage / Current Protector
Operation manual
English
Consulting
Consulting
FAQ
Q: What are the key precautions for the installation and maintenance of GPS8-06 protector?
A:

·Installation requirements: It must be installed by a qualified electrician, supporting upper wire (U-shaped)/lower wire (D-type), compatible with EN/IEC 60715 standard 35mm DIN rail, and maintaining a reasonable distance from surrounding equipment during installation;
·Maintenance taboos: The equipment does not have isolation function. Before maintenance, it is necessary to disconnect the higher-level MCB and prohibit live disassembly or wiring;
·Environmental adaptation: Working temperature -20 ℃~+60 ℃, protection level IP40/IP20, keep away from dust, corrosive gases, and strong electromagnetic interference;
·Fault handling: Automatic reset is enabled by default (reset time 2s~900s, factory 30s), and can be turned off. At this time, if there is a fault, press the "decrease button" to manually reset.

Q: What is the GPS8-06 Voltage/Current Protector?
A:

The GPS8-06 Voltage/Current Protector is a compact electrical safety device integrating three-in-one protection (overvoltage, undervoltage, overcurrent) and intelligent monitoring, specially designed for residential power distribution, small commercial premises and old circuit renovation scenarios. Compatible with AC 220V rated voltage and 45-65Hz frequency, it covers a working voltage range of 80V-400V, and can real-time monitor core parameters such as voltage, current, power and energy consumption. When a circuit abnormality occurs, it quickly cuts off the fault loop within 0.1-10 seconds, and supports automatic reset (adjustable reset time) after the fault is eliminated. Equipped with an LCD digital display and LED fault indicators, it adopts 1-MODULE standard DIN rail installation, which is compact, lightweight and easy to operate, fully protecting electrical equipment and personal electrical safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.