Full SF6 Gas Insulated ring main unit /Switchgear(RMU) 36kV 40.5kV

  • Full SF6 Gas Insulated ring main unit /Switchgear(RMU) 36kV 40.5kV

Key attributes

Brand Rw Energy
Series RMR
Rated voltage 24kV/36kV
Rated Current 630/1250/2500A
Rated Frequency 50Hz / 60Hz

Product descriptions from the supplier

Description
Description
RMR-36/40.5kV is a fully sealed SF6 gas-insulated switchgear, widely known as Ring Main Unit (RMU). It is mainly used for switching, protection and control in secondary power distribution networks, and fully complies with IEC and GB standards including IEC62271-200.
This series provides three modular unit configurations:
  • Code C: Cable switch unit with 3-position operation, equipped with live display, surge arresters and ground fault detection.
  • Code F: Fuse combination unit with switch-fuse tripping and interlock system, supporting reliable overcurrent protection.
  • Code V: Vacuum circuit breaker unit integrated with current transformer, microcomputer protection and complete auxiliary components.
The microcomputer protection module is CT-powered and requires no extra PT supply, realizing stable and simplified circuit protection. Fuse units comply with IEC 60420, while VCB units meet IEC 62271-100 and GB1984-2003.

Key Features

  • Fully SF6 gas-insulated and sealed structure, stable performance and strong anti-pollution ability.
  • Modular C/F/V design for flexible combination to meet different distribution requirements.
  • Passive microcomputer protection powered by CT, no additional PT power supply needed.
  • Complete with live display, surge arresters and ground fault components for high safety.
  • Complies with IEC and GB international standards, suitable for global power systems.
  • Excellent environmental adaptability up to 4000m altitude and strong seismic resistance.

Tecnical data

No
Item
Unit
Data
1
Rated voltage
kV
24/36
2
Power Frequency withstand voltage
Dry
60/70/80/95
Wet
Lightning Impulse withstand Voltage
(peak value)
125/150/170/185/200
3
Rated Current
A
630/1250/2500
4
Rated short circuit breaking current (peak)
kA
20/25(V) 31.5(F)
5
Rated closed-loop breaking current
A
630/1250(C)
6
Rated cable charging interrupting current
A
50(C)
7
Rated line cable charging interrupting current
A
10(C)
8
Rated off circuit transformer breaking current
A
16
9
Rated making current (peak)
kA
50(63/80)/2.5(main switch/grounding)
10
Rated  withstand current (peak)
11
Rated short time withstand current
16/20/25/31.5
12
Rated short time withstand time
S
3/4
13
Mechanical life
times
C/F(2000)V(10,000)
14
Main busbar
A
630/1250/2000/2500

Application Scenarios

  • Urban and rural 36kV / 40.5kV secondary power distribution networks.
  • Industrial parks, factories, mines and infrastructure power supply systems.
  • Compact distribution stations, box-type substations and underground power rooms.
  • Commercial buildings, residential quarters, data centers and public facilities.
  • High-altitude areas and harsh environment power projects.
  • Power grid renovation and intelligent distribution automation projects.

Service Environment

  • Ambient temperature: ±40℃, daily average ≤25℃
  • Altitude: up to 4000m
  • Wind speed: ≤35m/s
  • Seismic intensity: ≤8 degree
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Design Solution of 24kV Dry Air Insulated Ring Main Unit
    The combination of Solid Insulation Assist + Dry Air Insulation represents the development direction for 24kV RMUs. By balancing insulation requirements with compactness and employing solid auxiliary insulation, insulation tests can be passed without significantly increasing phase-to-phase and phase-to-ground dimensions. Encapsulating the pole column solidifies the insulation for the vacuum interrupter and its connecting conductors.Maintaining the 24kV outgoing busbar phase spacing at 110mm, the
    08/16/2025
  • Optimization Design Scheme for the 12kV Air-Insulated Ring Main Unit Isolating Gap to Reduce Breakdown Discharge Probability
    With the rapid development of the power industry, the ecological concept of low-carbon, energy-saving, and environmental protection has been deeply integrated into the design and manufacturing of power supply and distribution electrical products. The Ring Main Unit (RMU) is a key electrical device in distribution networks. Safety, environmental protection, operational reliability, energy efficiency, and economy are inevitable trends in its development. Traditional RMUs are primarily represented
    08/16/2025
  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.