• DS4D 420kV 550kV High voltage disconnect switch
DS4D 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS4D-550/4000-63
DS4D-550/2500-50
DS4D-420/4000-63
DS4D-420/2500-50
Basic info
Brand ROCKWILL
Model NO. DS4D 420kV 550kV High voltage disconnect switch
Rated voltage 420kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS4D
Product Detail

Product introduction

This switch Switch Disconnector is a Kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz.lt is used for breaking or connecting HV lines under no loads so that there lines can be changed and connected and the way the electricity runs is changed. In addition, it can be used to exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and dose the bus to switch current

Main characteristic

  • The product chassis adopts an integrated design to ensure that the upper conductive does not generate a large displacement under the tensile force of the terminal, and improves the reliability of the product closing.
  • The bearing housing is designed according to the maintenance-free requirements. The bearing seat is sealed by a fully sealed rain cover, wool felt seal and sealing ring. Water vapor, dust and harmful gases cannot enter, and the grease in the bearing does not drain during the life cycle., does not cure, especially suitable for Windy sand areas
  • The finger is made of pure copper and has a silver plating process. It has strong flow capacity and tong mechanical life. The stamping process ensures the reliability of contact and finger contact
  • The contact finger pressure is proportional to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible Wire).
  • The earth switch uses a torsion spring to balance its own weight and torque, making it light and flexible. The base adopts a suspended structure. which is convenient for on-site adjustment. The grounding switch static contact adopts self-powered plum-shaped finger. which has simple structure, many contact points and high technical performance index.
  • Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

Order notice 

Please indicate the service condition;

Please indicate the product type、 Rated voltage、 Rated current、 Rated short time withstand current、creepage distance and so on;

Please indicate the motor voltage、 control circuit’s voltage、pollution region and auxiliary switch connection number;

Please indicate whether the steel bracket is provided;

Please indicate whether the interphase cable is provided, and specify the cable length and type;

Please indicate other special requirements

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!